From 29aeb0bd00e4f6b31e03234e9a1d6e2c9f7adc34 Mon Sep 17 00:00:00 2001 From: Fredrik Ahlgren Date: Sun, 22 Nov 2026 13:19:59 +0100 Subject: [PATCH 1/2] fix(goodwe): read PV, battery and meter from GoodWe's map (2.3.0) The driver read most values from the wrong registers: battery power from 35180 (the battery voltage), battery V and A from 35178/35179 (BUS and NBUS voltages), SoC from 35182, total PV from PV1 alone scaled by 0.1, grid frequency from 35113 (PV3 power) and the meter from the inverter's own phase registers. Addresses, types and scales now follow GoodWe's "Modbus Protocol Hybrid for Energy Storage Inverters" (2 February 2024); signs follow evcc's goodwe-hybrid template and the goodwe library. No battery stream when 35184 says none, no meter when 36004 says the inverter does not hear one, and no field from a read that failed. The orphaned community-v1 and gw8kn-et-hk3000 Lua fixtures, which no test ran, are removed. Refs srcfl/device-drivers#264 Co-Authored-By: Claude Opus 5.5 Signed-off-by: Fredrik Ahlgren --- CHANGELOG.md | 37 ++ SUPPORT_STATUS.md | 4 +- drivers/lua/goodwe.lua | 398 +++++++++--------- drivers/tests/invented-number-baseline.json | 1 - drivers/tests/lua_harness/goodwe_fixtures.lua | 76 ---- .../tests/lua_harness/test_all_drivers.lua | 15 +- .../lua_harness/test_goodwe_failures.lua | 67 --- .../lua_harness/test_goodwe_ftw_contract.lua | 65 --- .../lua_harness/test_goodwe_profiles.lua | 92 ---- drivers/tests/test_goodwe_battery_now.py | 9 +- drivers/tests/test_goodwe_map.py | 327 ++++++++++++++ index.yaml | 6 +- manifests/goodwe.yaml | 12 +- support-status.json | 2 +- 14 files changed, 595 insertions(+), 516 deletions(-) delete mode 100644 drivers/tests/lua_harness/goodwe_fixtures.lua delete mode 100644 drivers/tests/lua_harness/test_goodwe_failures.lua delete mode 100644 drivers/tests/lua_harness/test_goodwe_ftw_contract.lua delete mode 100644 drivers/tests/lua_harness/test_goodwe_profiles.lua create mode 100644 drivers/tests/test_goodwe_map.py diff --git a/CHANGELOG.md b/CHANGELOG.md index e7844ad3..bcf2441b 100644 --- a/CHANGELOG.md +++ b/CHANGELOG.md @@ -122,6 +122,43 @@ The driver is read-only, so no command went the wrong way. Not yet checked on hardware: on a Growatt, `battery.w` should be positive while the SoC rises. +### goodwe 2.3.0 + +The driver now reads PV, battery and meter values from the registers in +GoodWe's own map, "Modbus Protocol Hybrid for Energy Storage Inverters" +(2 February 2024). evcc's goodwe-hybrid template and the goodwe library read +the same registers and give the signs (srcfl/device-drivers#264). Not yet +checked on hardware. + +- **Battery.** Power is the S32 at 35182-35183, voltage 35180, current + 35181, SoC 37007 from the BMS block. GoodWe counts discharge as positive, + so the driver turns power and current round. Earlier releases read power + from 35180 (the battery voltage), voltage and current from 35178/35179 + (the BUS and NBUS voltages) and SoC from 35182. SoC is sent only while + the BMS talks to the inverter (37011), like the other BMS figures. When + 35184 says there is no battery, no battery stream goes out. +- **PV.** Power is the sum of the four MPPT powers (U32 W at 35105, 35109, + 35113, 35117). Earlier releases read PV1 power alone and scaled it by 0.1. + PV2 voltage and current are 35107/35108, not 35109/35110. Grid frequency + is 35123, not 35113 (PV3 power). +- **Meter.** The meter comes from the meter block: total power 36025, power + per phase 36019/36021/36023 (S32), frequency 36014, energy sold and bought + 36015/36017 (float32 Wh), and voltage and current per phase 36052-36057. + GoodWe counts export as positive; the driver turns it round. Earlier + releases read the inverter's own phase registers at 35121-35141 and the + energy counters at 35195/35199, which are inverter counters at best and, + for 35199, a daily value. No meter is sent while 36004 says the inverter + does not hear its meter. +- **Never fabricate.** A read that fails is left out, never sent as 0. The + driver is clean in `invented-number-baseline.json` (was 23 fields). +- **Not handled.** GoodWe's map points ARM firmware 9 and older at + 36005-36008 for meter power. The driver reads the newer registers, as + evcc does, and does not read the firmware version. +- **Tests.** `test_goodwe_map.py` encodes the map. The four Lua files under + `drivers/tests/lua_harness/` for the `community-v1` and `gw8kn-et-hk3000` + profiles are removed: no test ran them, and the driver lost those + profiles in #27. + ### goodwe 2.2.0, solis 2.2.0, sofar 2.2.0, solax 1.2.0, saj 1.3.0, growatt 2.2.0, solinteg 1.2.0 These drivers report what the battery can do now, where the device says so diff --git a/SUPPORT_STATUS.md b/SUPPORT_STATUS.md index 035e94bb..2948ba68 100644 --- a/SUPPORT_STATUS.md +++ b/SUPPORT_STATUS.md @@ -68,8 +68,8 @@ Catalog source is not proof that a target can install or run a driver. | goe | 1.1.0 | blixt-l1 | not_assessed | — | not_recorded | not_assessed | | goe_http | 1.1.0 | ftw-core | not_assessed | — | not_recorded | not_assessed | | goe_http | 1.1.0 | blixt-l1 | not_assessed | — | not_recorded | not_assessed | -| goodwe | 2.2.0 | ftw-core | not_assessed | — | not_recorded | not_assessed | -| goodwe | 2.2.0 | blixt-l1 | not_assessed | — | not_recorded | not_assessed | +| goodwe | 2.3.0 | ftw-core | not_assessed | — | not_recorded | not_assessed | +| goodwe | 2.3.0 | blixt-l1 | not_assessed | — | not_recorded | not_assessed | | growatt | 2.2.2 | ftw-core | not_assessed | — | not_recorded | not_assessed | | growatt | 2.2.2 | blixt-l1 | not_assessed | — | not_recorded | not_assessed | | hardybarth | 1.1.1 | ftw-core | not_assessed | — | not_recorded | not_assessed | diff --git a/drivers/lua/goodwe.lua b/drivers/lua/goodwe.lua index 39cbca6e..d6b64a0e 100644 --- a/drivers/lua/goodwe.lua +++ b/drivers/lua/goodwe.lua @@ -4,7 +4,9 @@ -- -- Register type: HOLDING (FC 0x03) -- Byte/word order: Big-Endian for multi-register values --- Tested: ET-Plus, EH series (GoodWe v2 LAN+WiFi dongle required) +-- Written for: ET-Plus, EH (GoodWe's ET platform, the 35000 register map). +-- Not checked on hardware yet. ES, EM and BP inverters speak another +-- protocol and are not covered. -- READ-ONLY: control not implemented. DRIVER = { @@ -13,7 +15,7 @@ DRIVER = { id = "goodwe", name = "GoodWe hybrid inverter", manufacturer = "GoodWe", - version = "2.2.0", + version = "2.3.0", protocols = { "modbus" }, capabilities = { "meter", "pv", "battery" }, read_only = true, @@ -66,40 +68,83 @@ local function probe_read(addr, count, kind) end ---------------------------------------------------------------------------- --- What the battery can do now (docs/WRITING-A-DRIVER.md) +-- Register map -- --- From GoodWe's own map, "GoodWe Modbus Protocol Hybrid for Energy Storage --- Inverters" (2 February 2024), which the goodwe library also follows: --- 35176 heat sink temperature S16 x 0.1 C --- 35180 battery 1 voltage U16 x 0.1 V (the BMS's --- value when it talks) --- 35184 battery 1 mode 0 = no battery, or --- disconnected +-- Addresses, types and scales from GoodWe's own map, "GoodWe Modbus +-- Protocol Hybrid for Energy Storage Inverters" (2 February 2024, in the +-- manifest's upstream_docs). evcc's goodwe-hybrid template and the goodwe +-- library (et.py) read the same registers. Neither document states a sign +-- in words; both integrations treat battery discharge and meter export as +-- positive (evcc scales meter power by -1 and passes battery power through +-- as "positive = discharging"; the goodwe library's house consumption adds +-- battery power and subtracts meter power). The driver turns both round at +-- the boundary. +-- +-- Inverter block, read as the goodwe library does from 35100: +-- 35103-35118 PV1..PV4: voltage U16 x 0.1 V, current U16 x 0.1 A, +-- power U32 W (35105, 35109, 35113, 35117) +-- 35123 R phase frequency, U16 x 0.01 Hz +-- 35176 heat sink temperature, S16 x 0.1 C +-- 35180 battery 1 voltage, U16 x 0.1 V (the BMS's value when it +-- talks to the inverter) +-- 35181 battery 1 current, S16 x 0.1 A +-- 35182-35183 battery 1 power, S32 W +-- 35184 battery 1 mode: 0 no battery or disconnected, 1 standby, +-- 2 discharging, 3 charging (Table 8-9) +-- 35191-35192 PV energy total, U32 x 0.1 kWh +-- Meter block, from the meter the inverter reads (36000 and up): +-- 36004 meter communication, 1 OK, 0 failed +-- 36014 meter frequency, U16 x 0.01 Hz +-- 36015-36016 total energy sold to the grid, float32 Wh +-- 36017-36018 total energy bought from the grid, float32 Wh +-- 36019-36024 meter power per phase, S32 W +-- 36025-36026 meter total power, S32 W +-- 36052-36057 meter voltage per phase U16 x 0.1 V, then current per +-- phase U16 x 0.1 A +-- The float32 energy unit is not in GoodWe's table; evcc and the goodwe +-- library both divide by 1000 for kWh, so the raw value is Wh. +-- +-- Earlier releases read most of these from the wrong place +-- (srcfl/device-drivers#264): battery power from 35180 (the voltage), +-- battery voltage and current from 35178/35179 (the BUS and NBUS voltages), +-- SoC from 35182, total PV from 35105 alone scaled by 0.1, PV2 from 35109, +-- grid frequency from 35113 (PV3 power), and the meter from the inverter's +-- own phase registers at 35121-35141. +-- +-- Known limits, left for a field report: +-- * GoodWe's table says to read 36019-36041 when the ARM firmware is +-- above version 9, and the older 36005-36008 (S16) before that. The +-- driver reads the newer ones, as evcc does for every ET model, and +-- does not read the firmware version. +-- * 36052-36057 are listed in GoodWe's February 2024 table. The goodwe +-- library reads them only on newer units, so on an older one the read +-- may fail; it is given up after three tries and the rest of the meter +-- still reports. +-- * evcc notes that 36017 reads 0 on some newer models (ETA-G20). +-- +-- What the battery can do now (docs/WRITING-A-DRIVER.md): -- 37000-37023 "BMS Operation Data", read as one block like the -- goodwe library does +-- 37003 BMS pack temperature x 0.1 C +-- 37004 max BMS charge current A +-- 37005 max BMS discharge current A +-- 37007 SoC of battery 1 % -- 37011 battery protocol, the codes of GoodWe's Table 8-33: -- 0x101 Pylontech, 0x102/0x105/0x106 BYD, 0x104 LG, -- 0x11E Dyness and others, 0x122 GoodWe. 0x11F, "EMS -- Battery", means the inverter has no direct link to the -- battery, and 0 means no protocol at all. --- 37003 BMS pack temperature x 0.1 C --- 37004 max BMS charge current A --- 37005 max BMS discharge current A -- 37020 max cell temperature x 0.1 C -- 37021 min cell temperature x 0.1 C -- The charge and discharge currents come from the BMS, so they move with -- temperature and charge level: a live limit, not a rating. -- -- A battery mode other than 0 says a battery is there, not that a BMS --- talks to the inverter. Without one the block answers zeros, and 0 C and --- 0 W would read as a cold battery that may not charge. So the block's --- figures count only while 37011 names a BMS protocol (not 0, 0x11F or --- 0xFFFF). A 0 A limit from a BMS that does talk is sent as 0 W. --- --- GoodWe's map puts the BUS voltage at 35178 and battery power at --- 35182-35183, where the battery reads in driver_poll still look. Those --- reads are left as they were (srcfl/device-drivers#264); this block reads --- its own voltage at 35180. +-- talks to the inverter. Without one the block answers zeros, and 0 C, +-- 0 W and 0 % would read as a cold, empty battery that may not charge. So +-- the block's figures, SoC included, count only while 37011 names a BMS +-- protocol (not 0, 0x11F or 0xFFFF). A 0 A limit from a BMS that does talk +-- is sent as 0 W. ---------------------------------------------------------------------------- -- A temperature outside -40..100 C or a power outside 0..100 kW is a @@ -138,6 +183,50 @@ local function bms_talks(protocol) and protocol ~= GOODWE_NO_DIRECT_BMS end +-- Unsigned and signed 32-bit values from two registers, high word first. +-- Both work on the 16-bit halves, so the sign survives a Lua build with +-- 32-bit integers (docs/WRITING-A-DRIVER.md, "Numbers"). +local function u32(hi, lo) + return (hi % 0x10000) * 0x10000 + (lo % 0x10000) +end + +local function s32(hi, lo) + hi = hi % 0x10000 + lo = lo % 0x10000 + if hi >= 0x8000 then + return (hi - 0x10000) * 0x10000 + lo + end + return hi * 0x10000 + lo +end + +-- IEEE 754 float32, high word first, on the 16-bit halves. NaN and +-- infinity mean "no value" and give nil. +local function f32(hi, lo) + hi = hi % 0x10000 + lo = lo % 0x10000 + local sign = 1 + if hi >= 0x8000 then sign = -1; hi = hi - 0x8000 end + local exponent = math.floor(hi / 128) + local mantissa = (hi % 128) * 65536 + lo + if exponent == 0xFF then return nil end + if exponent == 0 then return sign * mantissa * 2 ^ -149 end + return sign * (1 + mantissa / 0x800000) * 2 ^ (exponent - 127) +end + +-- A lifetime energy counter in Wh, or nil when it is not a count. +local function energy_wh(hi, lo) + local wh = f32(hi, lo) + if wh == nil or wh < 0 then return nil end + return wh +end + +-- 0xFFFF in a meter voltage or current means "no value" (evcc decodes +-- these registers as uint16 with that sentinel). +local function tenths(raw) + if raw == nil or raw == 0xFFFF then return nil end + return raw * 0.1 +end + ---------------------------------------------------------------------------- -- Initialization ---------------------------------------------------------------------------- @@ -148,48 +237,27 @@ end ---------------------------------------------------------------------------- -- Telemetry polling +-- +-- A stream goes out only when its defining read answered, and each field +-- only from a register that answered (docs/WRITING-A-DRIVER.md, "Never +-- fabricate"). ---------------------------------------------------------------------------- -function driver_poll() - ------------------------------------------------------------------------ - -- PV - ------------------------------------------------------------------------ - - -- PV total power: 35105-35106, U32 BE × 0.1 W - local pvw_regs = probe_read(35105, 2, "holding") - local pv_w = 0 - if pvw_regs then - pv_w = host.decode_u32_be(pvw_regs[1], pvw_regs[2]) * 0.1 - end - - -- PV1: voltage @ 35103 (U16 × 0.1 V), current @ 35104 (U16 × 0.1 A) - local m1_regs = probe_read(35103, 2, "holding") - local mppt1_v, mppt1_a = 0, 0 - if m1_regs then - mppt1_v = m1_regs[1] * 0.1 - mppt1_a = m1_regs[2] * 0.1 - end - - -- PV2: voltage @ 35109 (U16 × 0.1 V), current @ 35110 (U16 × 0.1 A) - local m2_regs = probe_read(35109, 2, "holding") - local mppt2_v, mppt2_a = 0, 0 - if m2_regs then - mppt2_v = m2_regs[1] * 0.1 - mppt2_a = m2_regs[2] * 0.1 - end - - -- Grid frequency: 35113, U16 × 0.01 Hz - local hz_regs = probe_read(35113, 1, "holding") - local hz = 0 - if hz_regs then - hz = hz_regs[1] * 0.01 - end - - -- PV lifetime generation: 35191-35192, U32 BE × 0.1 kWh - local pvgen_regs = probe_read(35191, 2, "holding") - local pv_gen_wh = 0 - if pvgen_regs then - pv_gen_wh = host.decode_u32_be(pvgen_regs[1], pvgen_regs[2]) * 0.1 * 1000 +local function poll_pv() + -- 35103-35123 in one read: four MPPTs, PV mode, then the R phase. + local regs = probe_read(35103, 21, "holding") + if not regs or regs[21] == nil then return end + + local pv_w = u32(regs[3], regs[4]) + u32(regs[7], regs[8]) + + u32(regs[11], regs[12]) + u32(regs[15], regs[16]) + local mppt1_v, mppt1_a = regs[1] * 0.1, regs[2] * 0.1 + local mppt2_v, mppt2_a = regs[5] * 0.1, regs[6] * 0.1 + local hz = regs[21] * 0.01 + + local lifetime_wh = nil + local energy = probe_read(35191, 2, "holding") + if energy and energy[2] ~= nil then + lifetime_wh = u32(energy[1], energy[2]) * 100 -- 0.1 kWh end host.emit("pv", { @@ -198,88 +266,56 @@ function driver_poll() mppt1_a = mppt1_a, mppt2_v = mppt2_v, mppt2_a = mppt2_a, - lifetime_wh = pv_gen_wh, + lifetime_wh = lifetime_wh, }) - -- Diagnostics: long-format TS DB host.emit_metric("pv_mppt1_v", mppt1_v) host.emit_metric("pv_mppt1_a", mppt1_a) host.emit_metric("pv_mppt2_v", mppt2_v) host.emit_metric("pv_mppt2_a", mppt2_a) host.emit_metric("grid_hz", hz) +end - ------------------------------------------------------------------------ - -- Battery - ------------------------------------------------------------------------ - - -- Battery voltage: 35178, U16 × 0.1 V - local bv_regs = probe_read(35178, 1, "holding") - local bat_v = 0 - if bv_regs then - bat_v = bv_regs[1] * 0.1 - end - - -- Battery current: 35179, I16 × 0.1 A - local ba_regs = probe_read(35179, 1, "holding") - local bat_a = 0 - if ba_regs then - bat_a = host.decode_i16(ba_regs[1]) * 0.1 - end - - -- Battery power: 35180, I16, W (positive=charge, negative=discharge — matches site convention) - local bw_regs = probe_read(35180, 1, "holding") - local bat_w = 0 - if bw_regs then - bat_w = host.decode_i16(bw_regs[1]) - end - - -- Battery SoC: 35182, U16, percent - local bsoc_regs = probe_read(35182, 1, "holding") - local bat_soc = 0 - if bsoc_regs then - bat_soc = bsoc_regs[1] / 100 -- percent → 0-1 fraction - end - +local function poll_battery() + -- 35180-35184: voltage, current, power (two words), mode. + local regs = probe_read(35180, 5, "holding") + if not regs or regs[5] == nil then return end + local mode = regs[5] + if mode == 0 then return end -- no battery, or disconnected + + local volts = regs[1] * 0.1 + -- GoodWe counts discharge as positive; the site counts charge as + -- positive. The current carries the same sign as the power, since the + -- voltage is never negative. + local amps = -host.decode_i16(regs[2]) * 0.1 local battery = { - w = bat_w, - v = bat_v, - a = bat_a, - soc = bat_soc, + w = -s32(regs[3], regs[4]), + v = volts, + a = amps, } - -- Battery 1 voltage and mode: 35180-35184. The BMS block is read only - -- while the mode says a battery is connected, and its figures count - -- only while 37011 says a BMS talks (see the top of this file). - local b1_regs = probe_read(35180, 5, "holding") - local b1_v, b1_mode - if b1_regs and b1_regs[5] ~= nil then - b1_v = b1_regs[1] * 0.1 - b1_mode = b1_regs[5] - end - - local bms_regs - if b1_mode ~= nil and b1_mode ~= 0 then - bms_regs = probe_read(37000, 24, "holding") - if bms_regs and bms_regs[24] == nil then bms_regs = nil end - if bms_regs and not bms_talks(bms_regs[12]) then -- 37011 - bms_regs = nil - end + local bms_regs = probe_read(37000, 24, "holding") + if bms_regs and bms_regs[24] == nil then bms_regs = nil end + if bms_regs and not bms_talks(bms_regs[12]) then -- 37011 + bms_regs = nil end if bms_regs then + battery.soc = bms_regs[8] / 100 -- 37007 + local bat_temp = goodwe_temp(bms_regs[4]) -- 37003 if bat_temp ~= nil then battery.temp_c = bat_temp host.emit_metric("battery_temp_c", bat_temp) end - local charge_w = limit_w(bms_regs[5], b1_v) -- 37004 + local charge_w = limit_w(bms_regs[5], volts) -- 37004 if charge_w ~= nil then battery.available_charge_W = charge_w host.emit_metric("battery_charge_limit_a", bms_regs[5]) host.emit_metric("battery_available_charge_w", charge_w) end - local discharge_w = limit_w(bms_regs[6], b1_v) -- 37005 + local discharge_w = limit_w(bms_regs[6], volts) -- 37005 if discharge_w ~= nil then battery.available_discharge_W = discharge_w host.emit_metric("battery_discharge_limit_a", bms_regs[6]) @@ -297,10 +333,51 @@ function driver_poll() end host.emit("battery", battery) - host.emit_metric("battery_dc_v", bat_v) - host.emit_metric("battery_dc_a", bat_a) + host.emit_metric("battery_dc_v", volts) + host.emit_metric("battery_dc_a", amps) +end + +local function poll_meter() + -- 36004-36026 in one read. Without the meter (36004 not 1) the + -- inverter has no grid reading to give, so no meter is sent. + local regs = probe_read(36004, 23, "holding") + if not regs or regs[23] == nil then return end + if regs[1] ~= 1 then return end + + -- GoodWe counts export as positive; the site counts import as positive. + local l1_w = -s32(regs[16], regs[17]) -- 36019 + local l2_w = -s32(regs[18], regs[19]) -- 36021 + local l3_w = -s32(regs[20], regs[21]) -- 36023 + local meter = { + w = -s32(regs[22], regs[23]), -- 36025 + l1_w = l1_w, + l2_w = l2_w, + l3_w = l3_w, + hz = regs[11] * 0.01, -- 36014 + export_wh = energy_wh(regs[12], regs[13]), -- 36015 + import_wh = energy_wh(regs[14], regs[15]), -- 36017 + } + host.emit_metric("meter_l1_w", l1_w) + host.emit_metric("meter_l2_w", l2_w) + host.emit_metric("meter_l3_w", l3_w) + + local va = probe_read(36052, 6, "holding") + if va and va[6] ~= nil then + meter.l1_v, meter.l2_v, meter.l3_v = tenths(va[1]), tenths(va[2]), tenths(va[3]) + meter.l1_a, meter.l2_a, meter.l3_a = tenths(va[4]), tenths(va[5]), tenths(va[6]) + for _, key in ipairs({"l1_v", "l2_v", "l3_v", "l1_a", "l2_a", "l3_a"}) do + if meter[key] ~= nil then host.emit_metric("meter_" .. key, meter[key]) end + end + end + + host.emit("meter", meter) +end + +function driver_poll() + poll_pv() + poll_battery() - -- Inverter heat sink temperature: 35176, S16 × 0.1 C. + -- Inverter heat sink temperature: 35176, S16 x 0.1 C. local itemp_regs = probe_read(35176, 1, "holding") if itemp_regs then local inv_temp = goodwe_temp(itemp_regs[1]) @@ -309,82 +386,7 @@ function driver_poll() end end - ------------------------------------------------------------------------ - -- Meter (grid connection point) - ------------------------------------------------------------------------ - - -- GoodWe reports grid meter power with the OPPOSITE sign from site - -- convention (positive = export). Negate at the boundary so everything - -- above the driver layer sees positive = import. - - -- Total: 35140-35141, I32 BE, W - local mw_regs = probe_read(35140, 2, "holding") - local meter_w = 0 - if mw_regs then - meter_w = -host.decode_i32_be(mw_regs[1], mw_regs[2]) - end - - -- Per-phase V/A interleaved at 35121-35126: L1_V, L1_A, L2_V, L2_A, L3_V, L3_A - -- (U16, voltage × 0.1 V, current × 0.1 A). One read, six registers. - local va_regs = probe_read(35121, 6, "holding") - local l1_v, l1_a, l2_v, l2_a, l3_v, l3_a = 0, 0, 0, 0, 0, 0 - if va_regs then - l1_v = va_regs[1] * 0.1 - l1_a = va_regs[2] * 0.1 - l2_v = va_regs[3] * 0.1 - l2_a = va_regs[4] * 0.1 - l3_v = va_regs[5] * 0.1 - l3_a = va_regs[6] * 0.1 - end - - -- Per-phase power at 35132-35137: L1, L2, L3 (I32 BE each pair). One read. - local lw_regs = probe_read(35132, 6, "holding") - local l1_w, l2_w, l3_w = 0, 0, 0 - if lw_regs then - l1_w = -host.decode_i32_be(lw_regs[1], lw_regs[2]) - l2_w = -host.decode_i32_be(lw_regs[3], lw_regs[4]) - l3_w = -host.decode_i32_be(lw_regs[5], lw_regs[6]) - end - - -- Total import energy: 35195-35196, U32 BE × 0.1 kWh - local imp_regs = probe_read(35195, 2, "holding") - local import_wh = 0 - if imp_regs then - import_wh = host.decode_u32_be(imp_regs[1], imp_regs[2]) * 0.1 * 1000 - end - - -- Total export energy: 35199-35200, U32 BE × 0.1 kWh - local exp_regs = probe_read(35199, 2, "holding") - local export_wh = 0 - if exp_regs then - export_wh = host.decode_u32_be(exp_regs[1], exp_regs[2]) * 0.1 * 1000 - end - - host.emit("meter", { - w = meter_w, - l1_w = l1_w, - l2_w = l2_w, - l3_w = l3_w, - l1_v = l1_v, - l2_v = l2_v, - l3_v = l3_v, - l1_a = l1_a, - l2_a = l2_a, - l3_a = l3_a, - hz = hz, - import_wh = import_wh, - export_wh = export_wh, - }) - host.emit_metric("meter_l1_w", l1_w) - host.emit_metric("meter_l2_w", l2_w) - host.emit_metric("meter_l3_w", l3_w) - host.emit_metric("meter_l1_v", l1_v) - host.emit_metric("meter_l2_v", l2_v) - host.emit_metric("meter_l3_v", l3_v) - host.emit_metric("meter_l1_a", l1_a) - host.emit_metric("meter_l2_a", l2_a) - host.emit_metric("meter_l3_a", l3_a) - + poll_meter() return 5000 end diff --git a/drivers/tests/invented-number-baseline.json b/drivers/tests/invented-number-baseline.json index 3bf2d056..1aa5f20d 100644 --- a/drivers/tests/invented-number-baseline.json +++ b/drivers/tests/invented-number-baseline.json @@ -24,7 +24,6 @@ "ctek_v2": 9, "deye": 26, "fronius": 10, - "goodwe": 23, "hello": 3, "janitza": 13, "kostal": 21, diff --git a/drivers/tests/lua_harness/goodwe_fixtures.lua b/drivers/tests/lua_harness/goodwe_fixtures.lua deleted file mode 100644 index a8694683..00000000 --- a/drivers/tests/lua_harness/goodwe_fixtures.lua +++ /dev/null @@ -1,76 +0,0 @@ --- Synthetic fixtures. Replace or add masked hardware captures after the pilot. - -return { - ["community-v1"] = { - batches = { - {35105, 2}, {35103, 2}, {35109, 2}, {35113, 1}, {35191, 2}, - {35178, 1}, {35179, 1}, {35180, 1}, {35182, 1}, {35183, 1}, - {35140, 2}, {35132, 2}, {35134, 2}, {35136, 2}, - {35121, 1}, {35123, 1}, {35125, 1}, - {35122, 1}, {35124, 1}, {35126, 1}, - {35195, 2}, {35199, 2}, - }, - registers = { - [35103] = {3500, 80}, - [35105] = {0, 50000}, - [35109] = {3400, 70}, - [35113] = {5000}, - [35191] = {0, 2000}, - [35178] = {5000}, - [35179] = {65436}, - [35180] = {1200}, - [35182] = {75}, - [35183] = {250}, - [35140] = {65535, 64036}, - [35132] = {65535, 65036}, - [35134] = {65535, 65036}, - [35136] = {65535, 65036}, - [35121] = {2300}, - [35123] = {2310}, - [35125] = {2290}, - [35122] = {50}, - [35124] = {55}, - [35126] = {60}, - [35195] = {0, 1000}, - [35199] = {0, 500}, - }, - failure_address = 35134, - expected = { - pv_w = -5000, - meter_w = 1500, - l1_w = 500, - battery_w = 1200, - soc = 0.75, - hz = 50, - import_wh = 100000, - export_wh = 50000, - }, - }, - ["gw8kn-et-hk3000"] = { - batches = { - {35107, 4}, {35123, 1}, {35125, 11}, {35138, 3}, - {35145, 13}, {35164, 5}, {35178, 6}, {35195, 5}, - }, - registers = { - [35107] = {3500, 80, 0, 2800}, - [35123] = {5000}, - [35125] = {1000, 0, 0, 0, 0, 1100, 0, 0, 0, 0, 1200}, - [35138] = {5000, 0, 64036}, - [35145] = {2300, 0, 0, 0, 0, 0, 2310, 0, 0, 0, 0, 0, 2290}, - [35164] = {1500, 0, 1600, 0, 1700}, - [35178] = {5000, 0, 1200, 0, 75, 250}, - [35195] = {0, 1000, 0, 0, 500}, - }, - failure_address = 35145, - expected = { - pv_w = -5000, - meter_w = 1500, - l1_w = 500, - battery_w = 1200, - soc = 0.75, - hz = 50, - import_wh = 100000, - export_wh = 50000, - }, - }, -} diff --git a/drivers/tests/lua_harness/test_all_drivers.lua b/drivers/tests/lua_harness/test_all_drivers.lua index 3f24af49..d1a2e1f5 100644 --- a/drivers/tests/lua_harness/test_all_drivers.lua +++ b/drivers/tests/lua_harness/test_all_drivers.lua @@ -135,9 +135,9 @@ local function setup_modbus_data(driver_name) -- and applies a specific formula. We set these to produce values in 0-1. --------------------------------------------------------------------------- - -- GoodWe: reg 35182, formula = val / 100 -> set to 50 => 0.50 - holding[35182] = 50 - input[35182] = 50 + -- GoodWe: reg 37007, formula = val / 100 -> set to 50 => 0.50 + holding[37007] = 50 + input[37007] = 50 -- Sungrow: reg 13022 (4th of 13019+4), formula = val * 0.1 / 100 -- bat_regs[4] * 0.1 / 100 -> set to 500 => 0.50 @@ -176,7 +176,7 @@ local function setup_modbus_data(driver_name) -- or 500 (=> 0.50 with *0.1/100) local soc_50_addrs = { -- Direct /100 pattern - 35182, -- GoodWe + 37007, -- GoodWe 843, -- Victron 588, -- Deye 1068, -- VARTA @@ -271,6 +271,11 @@ local function setup_modbus_data(driver_name) input[40960] = 1 input[40971] = 1 input[40972] = 5000 + elseif driver_name == "goodwe" then + -- The inverter hears its meter (36004 = 1) and the BMS talks + -- (37011 = 0x101 Pylontech). SoC 37007 is set with the others below. + holding[36004] = 1 + holding[37011] = 0x101 end --------------------------------------------------------------------------- @@ -280,7 +285,7 @@ local function setup_modbus_data(driver_name) -- Pattern: val / 100 => set to 50 local soc_div100 = { - 35182, -- GoodWe + 37007, -- GoodWe 843, -- Victron modbus 588, -- Deye 1068, -- VARTA diff --git a/drivers/tests/lua_harness/test_goodwe_failures.lua b/drivers/tests/lua_harness/test_goodwe_failures.lua deleted file mode 100644 index d60c6be2..00000000 --- a/drivers/tests/lua_harness/test_goodwe_failures.lua +++ /dev/null @@ -1,67 +0,0 @@ -local profile = arg[1] -local scenario = arg[2] -if not profile or not scenario then - error("profile and failure scenario are required") -end - -dofile("drivers/tests/lua_harness/host_mock.lua") -local fixtures = dofile("drivers/tests/lua_harness/goodwe_fixtures.lua") -local fixture = fixtures[profile] -if not fixture then error("unknown fixture profile: " .. tostring(profile)) end - -local function load_fixture() - host.reset() - for address, registers in pairs(fixture.registers) do - host._modbus_registers.holding[address] = registers - end - dofile("drivers/lua/goodwe.lua") - driver_init({profile = profile}) -end - -local function emission_count() - local count = 0 - for _, stream in ipairs({"pv", "battery", "meter"}) do - count = count + ((host._emitted[stream] and #host._emitted[stream]) or 0) - end - return count -end - -load_fixture() - -if scenario == "all" then - host._modbus_read_error = "simulated Modbus timeout" - local ok = pcall(driver_poll) - if ok then error("total timeout did not fail the poll") end - if emission_count() ~= 0 then error("total timeout emitted telemetry") end -elseif scenario == "middle" then - host._modbus_read_fail_addresses[fixture.failure_address] = "simulated batch timeout" - local ok = pcall(driver_poll) - if ok then error("middle batch timeout did not fail the poll") end - if emission_count() ~= 0 then error("middle batch timeout emitted telemetry") end -elseif scenario == "short" then - local last = fixture.batches[#fixture.batches] - host._modbus_read_short_counts[last[1]] = last[2] - 1 - local ok = pcall(driver_poll) - if ok then error("short batch did not fail the poll") end - if emission_count() ~= 0 then error("short batch emitted telemetry") end -elseif scenario == "sentinel" then - if profile ~= "gw8kn-et-hk3000" then error("sentinel is only a GW8KN fixture") end - fixture.registers[35138][1] = 65535 - local ok = pcall(driver_poll) - if ok then error("negative PV sentinel did not fail the poll") end - if emission_count() ~= 0 then error("negative PV sentinel emitted telemetry") end -elseif scenario == "recover" then - driver_poll() - if emission_count() ~= 3 then error("first complete poll did not emit all streams") end - host._modbus_read_fail_addresses[fixture.failure_address] = "simulated mute session" - local ok = pcall(driver_poll) - if ok then error("mute session did not fail the poll") end - if emission_count() ~= 3 then error("failed recovery poll emitted telemetry") end - host._modbus_read_fail_addresses = {} - driver_poll() - if emission_count() ~= 6 then error("post-reconnect poll did not recover") end -else - error("unknown failure scenario: " .. scenario) -end - -if host._modbus_write_attempts ~= 0 then error("read-only failure path attempted a write") end diff --git a/drivers/tests/lua_harness/test_goodwe_ftw_contract.lua b/drivers/tests/lua_harness/test_goodwe_ftw_contract.lua deleted file mode 100644 index ef2ad609..00000000 --- a/drivers/tests/lua_harness/test_goodwe_ftw_contract.lua +++ /dev/null @@ -1,65 +0,0 @@ -dofile("drivers/tests/lua_harness/host_mock.lua") -host.reset() - --- Model the FTW v1 host exactly for the calls GoodWe uses. The old generic --- aliases do not exist in FTW and must not hide a source compatibility bug. -host.decode_u32 = nil -host.decode_i32 = nil -host.decode_u32_be = function(hi, lo) - return (hi & 0xFFFF) * 65536 + (lo & 0xFFFF) -end -host.decode_i32_be = function(hi, lo) - local value = (hi & 0xFFFF) * 65536 + (lo & 0xFFFF) - if value >= 0x80000000 then return value - 0x100000000 end - return value -end -host.log = function(level, message) - if type(level) ~= "string" or type(message) ~= "string" then - error("FTW host.log requires level and message") - end -end - -dofile("drivers/lua/goodwe.lua") - -if type(DRIVER) ~= "table" or DRIVER.id ~= "goodwe" or type(DRIVER.version) ~= "string" then - error("GoodWe FTW identity metadata is wrong") -end -if DRIVER.host_api_min ~= 1 or DRIVER.host_api_max ~= 1 or DRIVER.read_only ~= true then - error("GoodWe FTW host API or read-only metadata is wrong") -end -if type(DRIVER.protocols) ~= "table" or DRIVER.protocols[1] ~= "modbus" then - error("GoodWe FTW protocol metadata is wrong") -end -if DRIVER.connection_defaults.unit_id ~= 1 then - error("GoodWe legacy connection default changed") -end -if type(driver_init) ~= "function" or type(driver_poll) ~= "function" or - type(driver_command) ~= "function" or type(driver_default_mode) ~= "function" then - error("GoodWe FTW lifecycle is incomplete") -end - -local fixture = dofile("drivers/tests/lua_harness/goodwe_fixtures.lua")["gw8kn-et-hk3000"] -for address, registers in pairs(fixture.registers) do - host._modbus_registers.holding[address] = registers -end - -driver_init({profile = "gw8kn-et-hk3000"}) -local ok, poll_error = pcall(driver_poll) -if not ok then error("GoodWe failed against the FTW v1 host: " .. tostring(poll_error)) end -if host._make ~= "GoodWe" then error("GoodWe did not report its make") end -if not host._emitted.pv or host._emitted.pv[1].w ~= -5000 then - error("GoodWe FTW PV decode or sign is wrong") -end -if not host._emitted.meter or host._emitted.meter[1].w ~= 1500 then - error("GoodWe FTW meter decode or sign is wrong") -end - -local writes_before = host._modbus_write_attempts -if driver_command("battery", 1000, {}) ~= false then - error("GoodWe read-only command did not reject control") -end -driver_default_mode() -driver_cleanup() -if host._modbus_write_attempts ~= writes_before then - error("GoodWe read-only lifecycle attempted a write") -end diff --git a/drivers/tests/lua_harness/test_goodwe_profiles.lua b/drivers/tests/lua_harness/test_goodwe_profiles.lua deleted file mode 100644 index abd9c7ff..00000000 --- a/drivers/tests/lua_harness/test_goodwe_profiles.lua +++ /dev/null @@ -1,92 +0,0 @@ -local profile = arg[1] -local mode = arg[2] or "import-charge" -local init_mode = arg[3] or "explicit" -if not profile then error("profile is required") end - -dofile("drivers/tests/lua_harness/host_mock.lua") -host.reset() -local fixtures = dofile("drivers/tests/lua_harness/goodwe_fixtures.lua") -local fixture = fixtures[profile] -if not fixture then error("unknown fixture profile: " .. tostring(profile)) end -if mode == "export-discharge" then - if profile == "community-v1" then - fixture.registers[35132] = {0, 500} - fixture.registers[35134] = {0, 500} - fixture.registers[35136] = {0, 500} - fixture.registers[35140] = {0, 1500} - fixture.registers[35180][1] = 64336 - else - fixture.registers[35138][3] = 1500 - fixture.registers[35164][1] = 500 - fixture.registers[35164][3] = 600 - fixture.registers[35164][5] = 700 - fixture.registers[35178][3] = 64336 - end - fixture.expected.meter_w = -1500 - fixture.expected.l1_w = -500 - fixture.expected.battery_w = -1200 -elseif mode == "zero-voltage" then - if profile ~= "gw8kn-et-hk3000" then error("zero-voltage is only a GW8KN fixture") end - fixture.registers[35145][1] = 0 - fixture.registers[35145][7] = 0 - fixture.registers[35145][13] = 0 -elseif mode == "night-zero" then - if profile ~= "gw8kn-et-hk3000" then error("night-zero is only a GW8KN fixture") end - fixture.registers[35138][1] = 0 - fixture.expected.pv_w = 0 -elseif mode ~= "import-charge" then - error("unknown fixture mode: " .. mode) -end -for address, registers in pairs(fixture.registers) do - host._modbus_registers.holding[address] = registers -end - -dofile("drivers/lua/goodwe.lua") -if init_mode == "legacy-default" then - driver_init({}) -else - driver_init({profile = profile}) -end -driver_poll() - -local function close(actual, expected, name) - if actual == nil or math.abs(actual - expected) > 0.000001 then - error(string.format("%s=%s, expected=%s", name, tostring(actual), tostring(expected))) - end -end - -local expected = fixture.expected -close(host._emitted.pv[1].w, expected.pv_w, "pv.w") -close(host._emitted.meter[1].w, expected.meter_w, "meter.w") -close(host._emitted.meter[1].l1_w, expected.l1_w, "meter.l1_w") -close(host._emitted.battery[1].w, expected.battery_w, "battery.w") -close(host._emitted.battery[1].soc, expected.soc, "battery.soc") -close(host._emitted.meter[1].hz, expected.hz, "meter.hz") -close(host._emitted.meter[1].import_wh, expected.import_wh, "meter.import_wh") -close(host._emitted.meter[1].export_wh, expected.export_wh, "meter.export_wh") -if mode == "zero-voltage" then - if host._emitted.meter[1].l1_a ~= nil or host._emitted.meter[1].l2_a ~= nil or - host._emitted.meter[1].l3_a ~= nil then - error("zero voltage fabricated a phase current") - end -end - -local reads = {} -for _, call in ipairs(host._calls) do - if call.func == "modbus_read" then table.insert(reads, call.args) end -end -if #reads ~= #fixture.batches then - error(string.format("profile %s made %d reads, expected %d", profile, #reads, #fixture.batches)) -end -for index, batch in ipairs(fixture.batches) do - local read = reads[index] - if read[1] ~= batch[1] or read[2] ~= batch[2] or read[3] ~= "holding" then - error(string.format("read %d was %s/%s/%s", index, tostring(read[1]), tostring(read[2]), tostring(read[3]))) - end -end - -local writes_before = host._modbus_write_attempts -if driver_command("battery", 1000, {}) ~= false then error("read-only command was accepted") end -driver_default_mode() -driver_cleanup() -if host._modbus_write_attempts ~= writes_before then error("read-only lifecycle attempted a write") end diff --git a/drivers/tests/test_goodwe_battery_now.py b/drivers/tests/test_goodwe_battery_now.py index 554a505c..25ff22c4 100644 --- a/drivers/tests/test_goodwe_battery_now.py +++ b/drivers/tests/test_goodwe_battery_now.py @@ -145,9 +145,14 @@ def test_goodwe_zero_limit_means_not_allowed_now(): def test_goodwe_no_battery_mode_leaves_bms_figures_out(): - """Mode 0 is "no battery": the BMS block is not read and nothing is sent.""" + """Mode 0 is "no battery": the BMS block is not read and nothing is sent. + + Since 2.3.0 no battery stream goes out either (docs/WRITING-A-DRIVER.md, + "A hybrid inverter may have no battery"); the goodwe library also treats + mode 0 as "no battery". + """ out = poll(registers(mode=0)) - assert out["BATTERY"] == "true" + assert out["BATTERY"] == "false" for field in FIELDS: assert out[f"F_{field}"] == "nil", field for metric in METRICS[:-1]: diff --git a/drivers/tests/test_goodwe_map.py b/drivers/tests/test_goodwe_map.py new file mode 100644 index 00000000..cc53e141 --- /dev/null +++ b/drivers/tests/test_goodwe_map.py @@ -0,0 +1,327 @@ +"""GoodWe ET / EH: PV, battery and meter come from GoodWe's documented map. + +Up to 2.2.0 the driver read most of these values from the wrong registers +(srcfl/device-drivers#264): battery power from 35180 (the battery voltage), +battery voltage from 35178 (the BUS voltage), SoC from 35182 (the high word +of battery power), total PV from 35105 (PV1 power alone, scaled by 0.1), +grid frequency from 35113 (PV3 power), and the meter from the inverter's +own phase registers. These tests encode GoodWe's map: + +- GoodWe, "Modbus Protocol Hybrid for Energy Storage Inverters", + 2 February 2024 (manifest upstream_docs): addresses, types and scales. +- evcc's goodwe-hybrid template and the goodwe library (et.py): the same + addresses, and the signs. GoodWe counts battery discharge and meter + export as positive; the driver turns both round. + +All values are synthetic, not a capture. +""" + +import math +import struct +import subprocess +from pathlib import Path + +import pytest + +ROOT = Path(__file__).resolve().parents[2] +LUA = ROOT / "lua55" +HARNESS = ROOT / "drivers" / "tests" / "lua_harness" +DRIVER = ROOT / "drivers" / "lua" / "goodwe.lua" + +pytestmark = pytest.mark.skipif( + not LUA.exists(), reason="run make check to build ./lua55") + +PYLONTECH = 0x101 # GoodWe Table 8-33, a BMS that talks + + +def u32(value: int) -> list[int]: + value &= 0xFFFFFFFF + return [value >> 16, value & 0xFFFF] + + +def s16(value: int) -> int: + return value & 0xFFFF + + +def f32(value: float) -> list[int]: + hi, lo = struct.unpack(">HH", struct.pack(">f", value)) + return [hi, lo] + + +NAN = [0x7FC0, 0x0000] + + +def pv_block(*, p1=2800, p2=2300, p3=0, p4=0, hz_raw=5001) -> list[int]: + """35103-35123: PV1..PV4 V/A/P, PV mode, R-phase V/A/Hz.""" + return ([3500, 80] + u32(p1) # 35103 V, 35104 A, 35105-35106 W + + [3400, 70] + u32(p2) # 35107-35110 + + [0, 0] + u32(p3) # 35111-35114 + + [0, 0] + u32(p4) # 35115-35118 + + [0, 0] # 35119-35120 PV mode + + [2300, 50, hz_raw]) # 35121 V, 35122 A, 35123 Hz + + +def battery_block(*, volts_raw=5120, amps=39, watts=2000, mode=2) -> list[int]: + """35180-35184. GoodWe signs: positive current and power = discharging.""" + return [volts_raw, s16(amps)] + u32(watts) + [mode] + + +def bms_block(*, soc=76, protocol=PYLONTECH) -> list[int]: + bms = [0] * 24 + bms[7] = soc # 37007, % + bms[11] = protocol # 37011 + return bms + + +def meter_block(*, comm=1, total=1200, phases=(400, 500, 300), + export_wh=1234500.0, import_wh=6789000.0, + hz_raw=5002) -> list[int]: + """36004-36026. GoodWe signs: positive meter power = export.""" + regs = [0] * 23 + regs[0] = comm # 36004 meter communication + regs[10] = hz_raw # 36014, x 0.01 Hz + regs[11:13] = (export_wh if isinstance(export_wh, list) + else f32(export_wh)) # 36015-36016 float + regs[13:15] = (import_wh if isinstance(import_wh, list) + else f32(import_wh)) # 36017-36018 float + regs[15:17] = u32(phases[0]) # 36019-36020 S32 + regs[17:19] = u32(phases[1]) # 36021-36022 + regs[19:21] = u32(phases[2]) # 36023-36024 + regs[21:23] = u32(total) # 36025-36026 + return regs + + +def site(over: dict[int, list[int]] | None = None) -> dict[int, list[int]]: + regs = { + 35103: pv_block(), + 35191: u32(123456), # x 0.1 kWh + 35176: [455], + 35180: battery_block(), + 37000: bms_block(), + 36004: meter_block(), + 36052: [2301, 2302, 2303, 51, 62, 73], + } + regs.update(over or {}) + return regs + + +def poll(regs: dict[int, list[int]], fail: tuple[int, ...] = ()) -> dict[str, str]: + setup = "\n".join( + f"host._modbus_registers.holding[{addr}] = " + "{" + ", ".join(str(v) for v in vals) + "}" + for addr, vals in regs.items()) + setup += "\n" + "\n".join( + f'host._modbus_read_fail_addresses[{addr}] = "Illegal Data Address"' + for addr in fail) + script = f''' +package.path = "{HARNESS}/?.lua;" .. package.path +require("host_mock") +host.reset() +{setup} +dofile("{DRIVER}") +driver_init({{}}) +local ok, err = pcall(driver_poll) +if not ok then print("POLL_ERROR " .. tostring(err)) os.exit(1) end +for _, der in ipairs({{"pv", "battery", "meter"}}) do + local list = host._emitted[der] + print("EMITTED_" .. der .. " " .. tostring(list ~= nil and #list > 0)) + if list and #list > 0 then + for k, v in pairs(list[#list]) do print(der .. "." .. k .. " " .. tostring(v)) end + end +end +for name, m in pairs(host._metrics) do print("metric." .. name .. " " .. tostring(m.value)) end +''' + result = subprocess.run([str(LUA), "-e", script], + capture_output=True, text=True, cwd=ROOT) + assert result.returncode == 0, result.stdout + result.stderr + return dict(line.split(" ", 1) + for line in result.stdout.strip().splitlines() if " " in line) + + +def val(out: dict[str, str], key: str) -> float: + assert key in out, f"{key} missing from {sorted(out)}" + return float(out[key]) + + +def close(out, key, expected): + assert math.isclose(val(out, key), expected, rel_tol=1e-6, abs_tol=1e-9), \ + f"{key}={out.get(key)}, expected {expected}" + + +# ---------------------------------------------------------------- PV + +def test_pv_power_is_the_sum_of_the_four_mppt_powers(): + # 35105, 35109, 35113, 35117 are U32 watts, one per MPPT. + out = poll(site({35103: pv_block(p1=2800, p2=2300, p3=150, p4=50)})) + close(out, "pv.w", -5300) + + +def test_pv_power_uses_both_words(): + out = poll(site({35103: pv_block(p1=70000, p2=0)})) + close(out, "pv.w", -70000) + + +def test_pv_mppt_voltages_and_currents(): + out = poll(site()) + close(out, "pv.mppt1_v", 350.0) + close(out, "pv.mppt1_a", 8.0) + close(out, "pv.mppt2_v", 340.0) # 35107, not 35109 + close(out, "pv.mppt2_a", 7.0) # 35108 + close(out, "metric.pv_mppt2_v", 340.0) + + +def test_pv_lifetime_energy(): + out = poll(site()) + close(out, "pv.lifetime_wh", 12345600) # 12345.6 kWh + + +def test_grid_frequency_comes_from_35123_not_pv3_power(): + out = poll(site({35103: pv_block(p3=4000, hz_raw=4998)})) + close(out, "metric.grid_hz", 49.98) + + +def test_failed_pv_read_sends_no_pv(): + out = poll(site(), fail=(35103,)) + assert out["EMITTED_pv"] == "false" + assert "metric.pv_mppt1_v" not in out + assert "metric.grid_hz" not in out + assert out["EMITTED_meter"] == "true" # the rest still reports + + +def test_failed_pv_energy_read_leaves_only_that_out(): + out = poll(site(), fail=(35191,)) + assert "pv.lifetime_wh" not in out + close(out, "pv.w", -5100) + + +# ----------------------------------------------------------- battery + +def test_battery_discharging_is_negative(): + # GoodWe: +2000 W and +3.9 A while discharging (Table 8-9 mode 2). + out = poll(site()) + close(out, "battery.w", -2000) + close(out, "battery.a", -3.9) + close(out, "battery.v", 512.0) + close(out, "metric.battery_dc_v", 512.0) + close(out, "metric.battery_dc_a", -3.9) + + +def test_battery_charging_is_positive_and_uses_both_words(): + out = poll(site({35180: battery_block(amps=-140, watts=-70000, mode=3)})) + close(out, "battery.w", 70000) + close(out, "battery.a", 14.0) + + +def test_battery_soc_comes_from_the_bms_block(): + out = poll(site()) + close(out, "battery.soc", 0.76) # 37007, not 35182 + + +def test_no_battery_sends_no_battery(): + # 35184 = 0: "No Battery, or battery disconnected". + out = poll(site({35180: battery_block(volts_raw=0, amps=0, watts=0, mode=0)})) + assert out["EMITTED_battery"] == "false" + assert "metric.battery_dc_v" not in out + assert out["EMITTED_pv"] == "true" + + +def test_failed_battery_read_sends_no_battery(): + out = poll(site(), fail=(35180,)) + assert out["EMITTED_battery"] == "false" + assert "metric.battery_dc_v" not in out + assert "metric.battery_dc_a" not in out + + +def test_soc_left_out_without_a_talking_bms(): + out = poll(site({37000: bms_block(soc=0, protocol=0x11F)})) + assert "battery.soc" not in out + close(out, "battery.w", -2000) + + +def test_failed_bms_read_leaves_soc_out(): + out = poll(site(), fail=(37000,)) + assert "battery.soc" not in out + close(out, "battery.w", -2000) + + +# ------------------------------------------------------------- meter + +def test_meter_export_is_negative(): + out = poll(site()) + close(out, "meter.w", -1200) # 36025, GoodWe +1200 = export + close(out, "meter.l1_w", -400) + close(out, "meter.l2_w", -500) + close(out, "meter.l3_w", -300) + close(out, "metric.meter_l1_w", -400) + + +def test_meter_import_is_positive_and_uses_both_words(): + out = poll(site({36004: meter_block(total=-70000, phases=(-40000, -20000, -10000))})) + close(out, "meter.w", 70000) + close(out, "meter.l1_w", 40000) + close(out, "meter.l3_w", 10000) + + +def test_meter_frequency_and_energy(): + out = poll(site()) + close(out, "meter.hz", 50.02) # 36014 + close(out, "meter.export_wh", 1234500.0) # 36015, float Wh + close(out, "meter.import_wh", 6789000.0) # 36017, float Wh + + +def test_meter_phase_voltage_and_current(): + out = poll(site()) + close(out, "meter.l1_v", 230.1) + close(out, "meter.l3_v", 230.3) + close(out, "meter.l1_a", 5.1) + close(out, "meter.l3_a", 7.3) + close(out, "metric.meter_l2_a", 6.2) + + +def test_meter_phase_block_missing_keeps_the_rest(): + out = poll(site(), fail=(36052,)) + assert "meter.l1_v" not in out + assert "meter.l1_a" not in out + close(out, "meter.w", -1200) + + +def test_no_meter_sends_no_meter(): + # 36004 = 0: the inverter does not hear its meter. + out = poll(site({36004: meter_block(comm=0, total=0, phases=(0, 0, 0))})) + assert out["EMITTED_meter"] == "false" + assert "metric.meter_l1_w" not in out + assert out["EMITTED_pv"] == "true" + assert out["EMITTED_battery"] == "true" + + +def test_failed_meter_read_sends_no_meter(): + out = poll(site(), fail=(36004,)) + assert out["EMITTED_meter"] == "false" + + +def test_nan_energy_is_left_out(): + out = poll(site({36004: meter_block(export_wh=NAN, import_wh=NAN)})) + assert "meter.export_wh" not in out + assert "meter.import_wh" not in out + close(out, "meter.w", -1200) + + +def test_no_read_of_the_old_wrong_registers(): + """35178 (BUS voltage) and 35113 alone are gone; 35132-35141 too.""" + script = f''' +package.path = "{HARNESS}/?.lua;" .. package.path +require("host_mock") +host.reset() +dofile("{DRIVER}") +driver_init({{}}) +pcall(driver_poll) +for _, c in ipairs(host._calls) do + if c.func == "modbus_read" then print(c.args[1] .. " " .. c.args[2]) end +end +''' + result = subprocess.run([str(LUA), "-e", script], + capture_output=True, text=True, cwd=ROOT) + assert result.returncode == 0, result.stdout + result.stderr + starts = {int(line.split()[0]) for line in result.stdout.split("\n") if line} + for old in (35178, 35179, 35182, 35113, 35109, 35140, 35132, 35121, 35195, 35199): + assert old not in starts, f"still reads {old}" diff --git a/index.yaml b/index.yaml index 54fef3cf..aa42d476 100644 --- a/index.yaml +++ b/index.yaml @@ -299,15 +299,15 @@ drivers: size_bytes: 17091 sha256: "f289d0ba9fbb7a20e48ba26d0c93c44af541cb4cc3fb62576a6a4e1fb21fe002" - name: "goodwe" - version: "2.2.0" + version: "2.3.0" tier: community protocol: modbus connectivity: local setup: [bridge] ders: [pv, battery, meter] control: false - size_bytes: 14972 - sha256: "2bd0ddc5df2754bf8e807aea05529d59809ef65282f4a55a5823e481339be363" + size_bytes: 16335 + sha256: "ffe3786034938b0ccc6cac76b1bcd64f28f2f6466877a2e5d9496b737fa8b39e" - name: "growatt" version: "2.2.2" tier: community diff --git a/manifests/goodwe.yaml b/manifests/goodwe.yaml index 6faca3c7..ef8b7d43 100644 --- a/manifests/goodwe.yaml +++ b/manifests/goodwe.yaml @@ -1,5 +1,5 @@ name: "goodwe" -version: "2.2.0" +version: "2.3.0" tier: community author: "frekes81 and Sourceful contributors" protocol: modbus @@ -17,13 +17,17 @@ upstream_docs: title: "goodwe library ET/EH register map" kind: register_map url_stability: volatile + - url: "https://raw.githubusercontent.com/evcc-io/evcc/master/templates/definition/meter/goodwe-hybrid.yaml" + title: "evcc goodwe-hybrid template (ET/EH/BH/BT register use and signs)" + kind: register_map + url_stability: volatile min_host_version: "1.10.0-beta.1" -size_bytes: 14972 +size_bytes: 16335 dkb_id: "" -sha256: "2bd0ddc5df2754bf8e807aea05529d59809ef65282f4a55a5823e481339be363" +sha256: "ffe3786034938b0ccc6cac76b1bcd64f28f2f6466877a2e5d9496b737fa8b39e" signature: "" bytecode_sha256: "" bytecode_signature: "" bytecode_size: 0 -changelog: "Report BMS pack temperature, charge and discharge limits and cell temperatures from GoodWe's 37000 block; drop the invented 0 C." +changelog: "Read PV, battery and meter from the registers in GoodWe's own map (srcfl/device-drivers#264); send no battery when 35184 says none and no meter when the inverter does not hear one." diff --git a/support-status.json b/support-status.json index dbeae8b9..b6a7eb8a 100644 --- a/support-status.json +++ b/support-status.json @@ -674,7 +674,7 @@ }, { "catalog_source": true, - "catalog_version": "2.2.0", + "catalog_version": "2.3.0", "driver_id": "goodwe", "targets": { "blixt-l1": { From 3026bac075c96894158783454dfc6f175fe1d633 Mon Sep 17 00:00:00 2001 From: Fredrik Ahlgren Date: Sun, 22 Nov 2026 13:42:07 +0100 Subject: [PATCH 2/2] fix(goodwe): gate meter power on ARM firmware; no-value sentinels GoodWe's map puts meter power at 36019-36041 only above ARM firmware version 9 (35019). On older firmware those registers would read 0 and the driver would send a confident 0 W site meter. No source gives the sign of the older 36005-36008, so the driver now reads 35019 once and sends no meter on ARM 9 or older, or while the version is unknown. PV power and energy of 0xFFFFFFFF (evcc's uint32 "no value") are left out, and an MPPT without a value adds nothing to PV power. SoC above 100 % (0xFFFF) is left out. The THIRD_PARTY_NOTICES entry for the removed gw8kn-et-hk3000 profile is dropped, since no file derives from it any more. Refs srcfl/device-drivers#264 Co-Authored-By: Claude Opus 5.5 Signed-off-by: Fredrik Ahlgren --- CHANGELOG.md | 14 ++++-- THIRD_PARTY_NOTICES.md | 28 ----------- drivers/lua/goodwe.lua | 56 ++++++++++++++++++---- drivers/tests/test_goodwe_map.py | 80 ++++++++++++++++++++++++++++++-- index.yaml | 4 +- manifests/goodwe.yaml | 4 +- 6 files changed, 139 insertions(+), 47 deletions(-) diff --git a/CHANGELOG.md b/CHANGELOG.md index bcf2441b..96e328ca 100644 --- a/CHANGELOG.md +++ b/CHANGELOG.md @@ -151,13 +151,19 @@ checked on hardware. does not hear its meter. - **Never fabricate.** A read that fails is left out, never sent as 0. The driver is clean in `invented-number-baseline.json` (was 23 fields). -- **Not handled.** GoodWe's map points ARM firmware 9 and older at - 36005-36008 for meter power. The driver reads the newer registers, as - evcc does, and does not read the firmware version. +- **Old firmware.** GoodWe's map puts meter power at 36019-36041 only + above ARM firmware version 9 (35019, read once), and at 36005-36008 + before that. No source gives the sign of the old registers, so on ARM 9 + or older, or while the version is unknown, no meter is sent rather than + a 0 W one. +- **No-value sentinels.** A PV power or PV energy of 0xFFFFFFFF (as evcc + reads them) is left out, and an MPPT without a value adds nothing to PV + power. A SoC above 100 % (0xFFFF) is left out. - **Tests.** `test_goodwe_map.py` encodes the map. The four Lua files under `drivers/tests/lua_harness/` for the `community-v1` and `gw8kn-et-hk3000` profiles are removed: no test ran them, and the driver lost those - profiles in #27. + profiles in #27. So is the `THIRD_PARTY_NOTICES.md` entry for the + `gw8kn-et-hk3000` profile, since no file derives from it any more. ### goodwe 2.2.0, solis 2.2.0, sofar 2.2.0, solax 1.2.0, saj 1.3.0, growatt 2.2.0, solinteg 1.2.0 diff --git a/THIRD_PARTY_NOTICES.md b/THIRD_PARTY_NOTICES.md index ea5bf4dc..6ab7fa33 100644 --- a/THIRD_PARTY_NOTICES.md +++ b/THIRD_PARTY_NOTICES.md @@ -4,31 +4,3 @@ Copyright © 1994–2024 Lua.org, PUC-Rio. Lua is distributed under the MIT license. The full notice is retained at the end of `tools/lua55-src/lua.h`. - -## GoodWe GW8KN-ET register profile - -The `gw8kn-et-hk3000` register profile in `drivers/lua/goodwe.lua` derives from -`srcfl/hugin-drivers/drivers/goodwe_et.lua` at commit -`3125960a80b5237e3a5ac609963ddb1302367938`. frekes81 contributed the source. - -MIT License - -Copyright (c) 2026 Sourceful Labs - -Permission is hereby granted, free of charge, to any person obtaining a copy -of this software and associated documentation files (the "Software"), to deal -in the Software without restriction, including without limitation the rights -to use, copy, modify, merge, publish, distribute, sublicense, and/or sell -copies of the Software, and to permit persons to whom the Software is -furnished to do so, subject to the following conditions: - -The above copyright notice and this permission notice shall be included in all -copies or substantial portions of the Software. - -THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR -IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY, -FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL THE -AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER -LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM, -OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE -SOFTWARE. diff --git a/drivers/lua/goodwe.lua b/drivers/lua/goodwe.lua index d6b64a0e..5076935f 100644 --- a/drivers/lua/goodwe.lua +++ b/drivers/lua/goodwe.lua @@ -92,6 +92,9 @@ end -- 35184 battery 1 mode: 0 no battery or disconnected, 1 standby, -- 2 discharging, 3 charging (Table 8-9) -- 35191-35192 PV energy total, U32 x 0.1 kWh +-- 35019 ARM firmware version, U16, read once (device info block) +-- 0xFFFFFFFF in a U32 power or energy means "no value" (evcc reads these +-- as uint32 with that sentinel); it is left out, never added. -- Meter block, from the meter the inverter reads (36000 and up): -- 36004 meter communication, 1 OK, 0 failed -- 36014 meter frequency, U16 x 0.01 Hz @@ -112,10 +115,11 @@ end -- own phase registers at 35121-35141. -- -- Known limits, left for a field report: --- * GoodWe's table says to read 36019-36041 when the ARM firmware is --- above version 9, and the older 36005-36008 (S16) before that. The --- driver reads the newer ones, as evcc does for every ET model, and --- does not read the firmware version. +-- * GoodWe's table says to read 36019-36041 when the ARM firmware +-- (35019) is above version 9, and 36005-36008 (S16) before that. On +-- older firmware 36019 and up would read 0, which looks like a site in +-- balance. No source gives the sign of 36005-36008, so on ARM 9 or +-- older, or while the version is unknown, no meter is sent. -- * 36052-36057 are listed in GoodWe's February 2024 table. The goodwe -- library reads them only on newer units, so on an older one the read -- may fail; it is given up after three tries and the rest of the meter @@ -190,6 +194,12 @@ local function u32(hi, lo) return (hi % 0x10000) * 0x10000 + (lo % 0x10000) end +-- A U32 power or energy, or nil for the 0xFFFFFFFF "no value" sentinel. +local function u32_value(hi, lo) + if hi % 0x10000 == 0xFFFF and lo % 0x10000 == 0xFFFF then return nil end + return u32(hi, lo) +end + local function s32(hi, lo) hi = hi % 0x10000 lo = lo % 0x10000 @@ -248,8 +258,14 @@ local function poll_pv() local regs = probe_read(35103, 21, "holding") if not regs or regs[21] == nil then return end - local pv_w = u32(regs[3], regs[4]) + u32(regs[7], regs[8]) - + u32(regs[11], regs[12]) + u32(regs[15], regs[16]) + -- PV1..PV4 power at 35105, 35109, 35113, 35117. An MPPT without a + -- value adds nothing; with no value at all there is no PV reading. + local pv_w = nil + for _, i in ipairs({3, 7, 11, 15}) do + local w = u32_value(regs[i], regs[i + 1]) + if w ~= nil then pv_w = (pv_w or 0) + w end + end + if pv_w == nil then return end local mppt1_v, mppt1_a = regs[1] * 0.1, regs[2] * 0.1 local mppt2_v, mppt2_a = regs[5] * 0.1, regs[6] * 0.1 local hz = regs[21] * 0.01 @@ -257,7 +273,8 @@ local function poll_pv() local lifetime_wh = nil local energy = probe_read(35191, 2, "holding") if energy and energy[2] ~= nil then - lifetime_wh = u32(energy[1], energy[2]) * 100 -- 0.1 kWh + local tenths_kwh = u32_value(energy[1], energy[2]) + if tenths_kwh ~= nil then lifetime_wh = tenths_kwh * 100 end end host.emit("pv", { @@ -300,7 +317,9 @@ local function poll_battery() end if bms_regs then - battery.soc = bms_regs[8] / 100 -- 37007 + if bms_regs[8] <= 100 then -- 37007 + battery.soc = bms_regs[8] / 100 -- 0xFFFF: no value + end local bat_temp = goodwe_temp(bms_regs[4]) -- 37003 if bat_temp ~= nil then @@ -337,7 +356,28 @@ local function poll_battery() host.emit_metric("battery_dc_a", amps) end +-- ARM firmware version (35019), read once. nil until it answers. +local arm_version = nil +local old_firmware_logged = false + local function poll_meter() + if arm_version == nil then + local fw = probe_read(35019, 1, "holding") + if fw and fw[1] ~= nil then arm_version = fw[1] end + end + -- Meter power sits at 36019-36026 only above ARM version 9 (see the + -- top of this file). Older or unknown firmware: no meter. + if arm_version == nil then return end + if arm_version <= 9 then + if not old_firmware_logged then + old_firmware_logged = true + host.log("info", string.format( + "GoodWe: ARM firmware %d keeps meter power at 36005-36008, " .. + "whose sign no source gives; no meter is sent", arm_version)) + end + return + end + -- 36004-36026 in one read. Without the meter (36004 not 1) the -- inverter has no grid reading to give, so no meter is sent. local regs = probe_read(36004, 23, "holding") diff --git a/drivers/tests/test_goodwe_map.py b/drivers/tests/test_goodwe_map.py index cc53e141..27b74010 100644 --- a/drivers/tests/test_goodwe_map.py +++ b/drivers/tests/test_goodwe_map.py @@ -98,6 +98,7 @@ def site(over: dict[int, list[int]] | None = None) -> dict[int, list[int]]: 35176: [455], 35180: battery_block(), 37000: bms_block(), + 35019: [19], # ARM firmware version 36004: meter_block(), 36052: [2301, 2302, 2303, 51, 62, 73], } @@ -105,7 +106,8 @@ def site(over: dict[int, list[int]] | None = None) -> dict[int, list[int]]: return regs -def poll(regs: dict[int, list[int]], fail: tuple[int, ...] = ()) -> dict[str, str]: +def poll(regs: dict[int, list[int]], fail: tuple[int, ...] = (), + polls: int = 1) -> dict[str, str]: setup = "\n".join( f"host._modbus_registers.holding[{addr}] = " "{" + ", ".join(str(v) for v in vals) + "}" @@ -120,8 +122,17 @@ def poll(regs: dict[int, list[int]], fail: tuple[int, ...] = ()) -> dict[str, st {setup} dofile("{DRIVER}") driver_init({{}}) -local ok, err = pcall(driver_poll) -if not ok then print("POLL_ERROR " .. tostring(err)) os.exit(1) end +for i = 1, {polls} do + host._emitted = {{}} + host._metrics = {{}} + local ok, err = pcall(driver_poll) + if not ok then print("POLL_ERROR " .. tostring(err)) os.exit(1) end +end +local reads = {{}} +for _, c in ipairs(host._calls) do + if c.func == "modbus_read" then reads[#reads + 1] = tostring(c.args[1]) end +end +print("READS " .. table.concat(reads, ",")) for _, der in ipairs({{"pv", "battery", "meter"}}) do local list = host._emitted[der] print("EMITTED_" .. der .. " " .. tostring(list ~= nil and #list > 0)) @@ -180,6 +191,26 @@ def test_grid_frequency_comes_from_35123_not_pv3_power(): close(out, "metric.grid_hz", 49.98) +def test_pv_mppt_without_a_value_is_left_out_of_the_sum(): + # 0xFFFFFFFF is "no value" (evcc reads these as uint32 with that + # sentinel). An unused PV3/PV4 must not add 4.3 GW. + out = poll(site({35103: pv_block(p1=2800, p2=2300, + p3=0xFFFFFFFF, p4=0xFFFFFFFF)})) + close(out, "pv.w", -5100) + + +def test_no_pv_power_at_all_sends_no_pv(): + nan = 0xFFFFFFFF + out = poll(site({35103: pv_block(p1=nan, p2=nan, p3=nan, p4=nan)})) + assert out["EMITTED_pv"] == "false" + + +def test_pv_lifetime_energy_without_a_value_is_left_out(): + out = poll(site({35191: [0xFFFF, 0xFFFF]})) + assert "pv.lifetime_wh" not in out + close(out, "pv.w", -5100) + + def test_failed_pv_read_sends_no_pv(): out = poll(site(), fail=(35103,)) assert out["EMITTED_pv"] == "false" @@ -238,6 +269,13 @@ def test_soc_left_out_without_a_talking_bms(): close(out, "battery.w", -2000) +@pytest.mark.parametrize("raw", [0xFFFF, 101]) +def test_soc_without_a_value_is_left_out(raw): + out = poll(site({37000: bms_block(soc=raw)})) + assert "battery.soc" not in out + close(out, "battery.w", -2000) + + def test_failed_bms_read_leaves_soc_out(): out = poll(site(), fail=(37000,)) assert "battery.soc" not in out @@ -285,6 +323,42 @@ def test_meter_phase_block_missing_keeps_the_rest(): close(out, "meter.w", -1200) +def test_arm_firmware_9_sends_no_meter(): + """ARM 9 and older keep meter power at 36005-36008, not 36019-36041. + + GoodWe's table says to use 36019-36041 only above ARM version 9 (35019). + On older firmware 36019+ would read 0 and look like a balanced site. + No source gives the sign of the old registers, so no meter is sent. + """ + out = poll(site({35019: [9]})) + assert out["EMITTED_meter"] == "false" + assert "metric.meter_l1_w" not in out + assert "36004" not in out["READS"].split(",") + assert out["EMITTED_pv"] == "true" + + +def test_arm_firmware_10_sends_the_meter(): + out = poll(site({35019: [10]})) + close(out, "meter.w", -1200) + + +def test_unknown_arm_firmware_sends_no_meter(): + out = poll(site(), fail=(35019,)) + assert out["EMITTED_meter"] == "false" + assert out["EMITTED_battery"] == "true" + + +def test_arm_firmware_is_read_once(): + out = poll(site(), polls=3) + assert out["READS"].split(",").count("35019") == 1 + close(out, "meter.w", -1200) + + +def test_arm_firmware_read_gives_up_after_three_tries(): + out = poll(site(), fail=(35019,), polls=6) + assert out["READS"].split(",").count("35019") == 3 + + def test_no_meter_sends_no_meter(): # 36004 = 0: the inverter does not hear its meter. out = poll(site({36004: meter_block(comm=0, total=0, phases=(0, 0, 0))})) diff --git a/index.yaml b/index.yaml index aa42d476..6672d7e3 100644 --- a/index.yaml +++ b/index.yaml @@ -306,8 +306,8 @@ drivers: setup: [bridge] ders: [pv, battery, meter] control: false - size_bytes: 16335 - sha256: "ffe3786034938b0ccc6cac76b1bcd64f28f2f6466877a2e5d9496b737fa8b39e" + size_bytes: 18014 + sha256: "2c38be160885144bf9baf1ab7f481de9f84bc38e22a5a9e9ba11991e4bdb1637" - name: "growatt" version: "2.2.2" tier: community diff --git a/manifests/goodwe.yaml b/manifests/goodwe.yaml index ef8b7d43..854b5bb0 100644 --- a/manifests/goodwe.yaml +++ b/manifests/goodwe.yaml @@ -22,9 +22,9 @@ upstream_docs: kind: register_map url_stability: volatile min_host_version: "1.10.0-beta.1" -size_bytes: 16335 +size_bytes: 18014 dkb_id: "" -sha256: "ffe3786034938b0ccc6cac76b1bcd64f28f2f6466877a2e5d9496b737fa8b39e" +sha256: "2c38be160885144bf9baf1ab7f481de9f84bc38e22a5a9e9ba11991e4bdb1637" signature: "" bytecode_sha256: ""