From d24d8e38dcd1b89b61a9b288a4b42cb2e687d7e2 Mon Sep 17 00:00:00 2001 From: Fredrik Ahlgren Date: Sun, 22 Nov 2026 13:21:05 +0100 Subject: [PATCH 1/2] fix(alphaess, kstar): read the vendor's own register maps (1.3.0) Both drivers read addresses that no source supports, so their PV, battery and meter values were probably wrong on real hardware. alphaess follows AlphaESS's parameter address table: grid meter power at 0x0021 (S32, import positive), phase A current at 0x0017, frequency at 0x001A; battery power at 0x0126 (AlphaESS: discharge positive, so negated), voltage at 0x0100, SoC at 0x0102 (0.1 %); PV as the sum of the six string powers at 0x041F-0x0433. The grid phase voltage is no longer sent: the sources disagree on its scale. kstar reads KSTAR's input registers from 3000 (Hybrid Inverter Modbus V2.9.1): PV at 3000-3025, battery voltage, power and SoC at 3063-3066, and the grid meter at 3097-3108. KSTAR gives no signs; following ha-solarman, meter power (export positive) and battery power (discharge positive) are negated. The model at 3045 says whether the S and T phases exist. Each stream goes out only when its read answered, never as zeros, so both drivers leave the invented-number baseline. Not verified on hardware. Refs srcfl/device-drivers#257 Co-Authored-By: Claude Opus 5.5 Signed-off-by: Fredrik Ahlgren --- CHANGELOG.md | 30 +++ SUPPORT_STATUS.md | 8 +- devices.yaml | 8 +- drivers/lua/alphaess.lua | 214 ++++++++-------- drivers/lua/kstar.lua | 234 ++++++++++-------- drivers/tests/invented-number-baseline.json | 2 - .../tests/lua_harness/test_all_drivers.lua | 7 +- drivers/tests/test_alphaess_battery_now.py | 12 +- drivers/tests/test_alphaess_map.py | 166 +++++++++++++ drivers/tests/test_kstar_battery_now.py | 12 +- drivers/tests/test_kstar_map.py | 181 ++++++++++++++ index.yaml | 12 +- manifests/alphaess.yaml | 24 +- manifests/kstar.yaml | 12 +- support-status.json | 4 +- 15 files changed, 673 insertions(+), 253 deletions(-) create mode 100644 drivers/tests/test_alphaess_map.py create mode 100644 drivers/tests/test_kstar_map.py diff --git a/CHANGELOG.md b/CHANGELOG.md index 750082e..94c1d44 100644 --- a/CHANGELOG.md +++ b/CHANGELOG.md @@ -2,6 +2,36 @@ ## [Unreleased] +### alphaess 1.3.0, kstar 1.3.0 + +Both drivers read the registers their vendor's own Modbus map gives +(srcfl/device-drivers#257). Earlier releases read addresses no source +supports, so their PV, battery and meter values were probably wrong. Each +stream now goes out only when its read answered, never as zeros. Written +from the sources in each manifest's `upstream_docs`. Not yet checked on +hardware. + +- **alphaess 1.3.0** follows AlphaESS's parameter address table. Grid meter: + total power at 0x0021 (S32, positive when drawing from the grid), phase A + current at 0x0017, frequency at 0x001A. Battery: power at 0x0126, which + AlphaESS counts positive when discharging, so the driver negates it; + voltage at 0x0100 and SoC at 0x0102 (0.1 %). PV: the sum of the six string + powers at 0x041F-0x0433, with string 1 voltage and current. Earlier + releases read meter energy counters and voltages at 0x0010-0x0028 as PV, + battery and meter values. The grid phase voltage is no longer sent: the + sources disagree on its scale. 0x0111/0x0112 are still not used as live + BMS limits. Firmware on the 2020 map (protocol V1.17, meter at + 0x0000-0x0019) is not covered. +- **kstar 1.3.0** reads KSTAR's input registers (function 04H) from 3000, as + KSTAR's Hybrid Inverter Modbus V2.9.1 gives them for the KSE, BluE-S and + E-series three-phase models: PV at 3000-3025, battery voltage, power and + SoC at 3063-3066 (beside the temperatures it already read) and the grid + meter at 3097-3108. KSTAR gives no signs; following ha-solarman, the + meter power (positive when exporting) and the battery power (positive + when discharging) are negated. The model at 3045 says whether the S and + T phases exist; an unknown model sends no meter. Earlier releases read + holding registers 10-54, which no source has. + ### fronius 2.3.0 Battery power, voltage and SoC now come from the registers Fronius's GEN24 diff --git a/SUPPORT_STATUS.md b/SUPPORT_STATUS.md index d020626..13ea60f 100644 --- a/SUPPORT_STATUS.md +++ b/SUPPORT_STATUS.md @@ -20,8 +20,8 @@ Catalog source is not proof that a target can install or run a driver. | acuvim | 0.4.3 | blixt-l1 | not_assessed | — | not_recorded | not_assessed | | alfen | 1.1.1 | ftw-core | not_assessed | — | not_recorded | not_assessed | | alfen | 1.1.1 | blixt-l1 | not_assessed | — | not_recorded | not_assessed | -| alphaess | 1.2.0 | ftw-core | not_assessed | — | not_recorded | not_assessed | -| alphaess | 1.2.0 | blixt-l1 | not_assessed | — | not_recorded | not_assessed | +| alphaess | 1.3.0 | ftw-core | not_assessed | — | not_recorded | not_assessed | +| alphaess | 1.3.0 | blixt-l1 | not_assessed | — | not_recorded | not_assessed | | ambibox | 1.2.0 | ftw-core | not_assessed | — | not_recorded | not_assessed | | ambibox | 1.2.0 | blixt-l1 | not_assessed | — | not_recorded | not_assessed | | ambibox_v2x | 1.1.1 | ftw-core | not_assessed | — | not_recorded | not_assessed | @@ -90,8 +90,8 @@ Catalog source is not proof that a target can install or run a driver. | konja-261-svk | 0.4.0 | blixt-l1 | not_assessed | — | not_recorded | not_assessed | | kostal | 2.2.0 | ftw-core | not_assessed | — | not_recorded | not_assessed | | kostal | 2.2.0 | blixt-l1 | not_assessed | — | not_recorded | not_assessed | -| kstar | 1.2.0 | ftw-core | not_assessed | — | not_recorded | not_assessed | -| kstar | 1.2.0 | blixt-l1 | not_assessed | — | not_recorded | not_assessed | +| kstar | 1.3.0 | ftw-core | not_assessed | — | not_recorded | not_assessed | +| kstar | 1.3.0 | blixt-l1 | not_assessed | — | not_recorded | not_assessed | | mennekes | 1.1.1 | ftw-core | not_assessed | — | not_recorded | not_assessed | | mennekes | 1.1.1 | blixt-l1 | not_assessed | — | not_recorded | not_assessed | | myuplink | 1.2.4 | ftw-core | not_assessed | — | not_recorded | not_assessed | diff --git a/devices.yaml b/devices.yaml index 75cee1c..1ffad57 100644 --- a/devices.yaml +++ b/devices.yaml @@ -135,7 +135,7 @@ manufacturers: protocols: - protocol: modbus driver: "alphaess" - version: "1.2.0" + version: "1.3.0" ders: [pv, battery, meter] control: false firmware_versions: "" @@ -146,7 +146,7 @@ manufacturers: protocols: - protocol: modbus driver: "alphaess" - version: "1.2.0" + version: "1.3.0" ders: [pv, battery, meter] control: false firmware_versions: "" @@ -761,7 +761,7 @@ manufacturers: protocols: - protocol: modbus driver: "kstar" - version: "1.2.0" + version: "1.3.0" ders: [pv, battery, meter] control: false firmware_versions: "" @@ -772,7 +772,7 @@ manufacturers: protocols: - protocol: modbus driver: "kstar" - version: "1.2.0" + version: "1.3.0" ders: [pv, battery, meter] control: false firmware_versions: "" diff --git a/drivers/lua/alphaess.lua b/drivers/lua/alphaess.lua index 47931f4..7ace3d8 100644 --- a/drivers/lua/alphaess.lua +++ b/drivers/lua/alphaess.lua @@ -3,8 +3,21 @@ -- Register type: HOLDING (FC 0x03) -- Port: 502 -- Community tier (untested) --- Register map from AlphaESS Modbus protocol v1.30 --- Hex addresses converted to decimal +-- +-- Register map: AlphaESS "Modbus_RTU/TCP Protocol" and its "Parameter +-- address table" (protocol history up to V1.39, 2024-11-29), as published +-- in ramonvanraaij/ha-alphaess-modbus docs/. The vendor's "Household +-- Register Map" table gives the same meter (0x0010-0x0036), battery +-- (0x0100-0x0148) and inverter (0x0400-0x0452) blocks for SMILE-SP, +-- SMILE-G3 (S3.6, S5, B5, S6, S8, T4-T20), SMILE-S6-HV, SMILE-T10-HV and +-- B3/B3PLUS. evcc's alpha-ess-smile template, dxoverdy/Alpha2MQTT and +-- senalse/ha-alphaess-modbus read the same addresses; they were used for +-- addresses, types and signs only. +-- +-- Older firmware: protocol V1.17 (2020) put the grid meter at +-- 0x0000-0x0019 (total power at 0x0006) and the inverter temperature at +-- 0x0429, where V1.39 has PV4. V1.19 (2020-10-20) changed the meter table. +-- This driver follows the current map only. -- No control code has been written for this inverter yet: driver_command -- only refuses. It says read_only so FTW and the catalog tell the owner @@ -15,7 +28,7 @@ DRIVER = { id = "alphaess", name = "AlphaESS inverter", manufacturer = "AlphaESS", - version = "1.2.0", + version = "1.3.0", protocols = { "modbus" }, capabilities = { "pv", "battery", "meter" }, read_only = true, @@ -31,13 +44,21 @@ PROTOCOL = "modbus" -- marked offline. Give a register three chances, then leave it alone until -- restart. Three rather than one: a single failure is not proof, the link may -- just have been slow. +-- +-- A short reply counts as a failure: every register asked for must be there, +-- or a decode further down would do arithmetic on nil. local GIVE_UP_AFTER = 3 local read_failures = {} local function probe_read(addr, count, kind) if (read_failures[addr] or 0) >= GIVE_UP_AFTER then return nil end local ok, regs = pcall(host.modbus_read, addr, count, kind) - if ok and regs and regs[1] ~= nil then + if ok and regs then + for i = 1, count do + if regs[i] == nil then ok = false break end + end + end + if ok and regs then read_failures[addr] = nil return regs end @@ -51,133 +72,102 @@ local function probe_read(addr, count, kind) return nil end +-- A cell temperature outside -40..100 C is a sentinel or a misread. +local function plausible_temp(c) + if c < -40 or c > 100 then return nil end + return c +end + function driver_init(config) host.set_make("AlphaESS") end function driver_poll() -- ---- PV ---- - - -- PV1 voltage: 0x0010=16, U16 × 0.1V - -- PV1 current: 0x0011=17, U16 × 0.1A - local pv1_regs = probe_read(16, 2, "holding") - local mppt1_v, mppt1_a = 0, 0 - if pv1_regs then - mppt1_v = pv1_regs[1] * 0.1 - mppt1_a = pv1_regs[2] * 0.1 - end - - -- PV total power: 0x0012=18, U16, W - local pvw_regs = probe_read(18, 1, "holding") - local pv_w = 0 - if pvw_regs then - pv_w = pvw_regs[1] - end - - -- Grid frequency: 0x0022=34, U16 × 0.01Hz - local hz_regs = probe_read(34, 1, "holding") - local hz = 0 - if hz_regs then - hz = hz_regs[1] * 0.01 + -- + -- 0x041D-0x0434 in one read: per string voltage (U16 x 0.1 V), current + -- (U16 x 0.1 A) and power (U32, 1 W), strings 1 to 6, four registers + -- apart. PV power is their sum. 0x0453 "Pv total power" is newer than + -- the 0x0400-0x0452 block the vendor lists for every model, so it is not + -- used. A PV meter for an AC-coupled inverter (0x00A1) is not added: + -- that inverter may have its own driver. + local pv_regs = probe_read(0x041D, 24, "holding") + if pv_regs then + local pv_w = 0 + for i = 3, 23, 4 do + pv_w = pv_w + host.decode_u32_be(pv_regs[i], pv_regs[i + 1]) + end + host.emit("pv", { + W = -pv_w, -- generation is negative (site convention) + mppt1_v = pv_regs[1] * 0.1, + mppt1_a = pv_regs[2] * 0.1, + }) end - -- Emit PV telemetry (W always negative for generation) - host.emit("pv", { - W = -pv_w, - mppt1_v = mppt1_v, - mppt1_a = mppt1_a, - }) - -- ---- Battery ---- + -- + -- 0x0100-0x0126 in one read (the "Household Battery" block): + -- 0x0100 battery voltage U16 x 0.1 V + -- 0x0102 battery SOC U16 x 0.1 % + -- 0x010D min cell temperature S16 x 0.1 C + -- 0x0110 max cell temperature S16 x 0.1 C + -- 0x0126 battery power S16, 1 W, "-: Charge, +: Discharge" + -- AlphaESS counts discharge as positive, so the power is negated here + -- (site convention: charging is positive). evcc reads it the same way. + -- senalse's map describes it as positive when charging; the vendor's + -- table, evcc and Alpha2MQTT all say the opposite. + -- + -- The block has no pack temperature, so temperature_C is left out. + -- 0x0111/0x0112 "Battery max charge/discharge current" (U16 x 0.1 A) + -- are not used as live limits: the vendor does not say they move with + -- the BMS, and Alpha2MQTT's author saw the charge value stay at 0 and + -- the discharge value at 100 A on a 50 A pack. A 0 would tell Core the + -- battery may not charge. + local bat_regs = probe_read(0x0100, 39, "holding") + if bat_regs then + local battery = { + W = -host.decode_i16(bat_regs[39]), -- 0x0126 + V = bat_regs[1] * 0.1, -- 0x0100 + } + local soc_raw = bat_regs[3] -- 0x0102 + if soc_raw <= 1000 then + battery.SoC_nom_fract = soc_raw / 1000 -- 0.1 % per bit + end + host.emit("battery", battery) - -- Battery power: 0x0020=32, I16, W (positive=charge, negative=discharge) - local bw_regs = probe_read(32, 1, "holding") - local bat_w = 0 - if bw_regs then - bat_w = host.decode_i16(bw_regs[1]) - end - - -- Battery voltage: 0x0021=33, U16 × 0.1V - local bv_regs = probe_read(33, 1, "holding") - local bat_v = 0 - if bv_regs then - bat_v = bv_regs[1] * 0.1 - end - - -- Battery SoC: 0x0024=36, U16, % - local bsoc_regs = probe_read(36, 1, "holding") - local bat_soc = 0 - if bsoc_regs then - bat_soc = bsoc_regs[1] / 100 -- percent to fraction - end - - -- Emit Battery telemetry - host.emit("battery", { - W = bat_w, - V = bat_v, - SoC_nom_fract = bat_soc, - }) - - -- Cell temperature range, for history: 0x010D=269 lowest cell, 0x0110=272 - -- highest cell, I16 x 0.1 C, in the battery block that starts at 0x0100. - -- Sources, for addresses and scales only: dxoverdy/Alpha2MQTT - -- Definitions.h and senalse/ha-alphaess-modbus docs/register_map.md. - -- Alpha2MQTT reads them as signed (Short); senalse lists uint16 x 0.1. - -- The driver decodes i16, which gives the same value for every - -- temperature at or above 0 C. A sub-zero cell read as uint16 would come - -- out near 6500 C and be dropped by the range check. - -- Both place battery power at 0x0126 and the grid meter at 0x0010..0x0021, - -- which is not what the reads above assume; that map needs its own - -- check against hardware. The block holds no pack temperature, so - -- `temperature_C` is left out. 0x0111/0x0112 (BMS max charge and - -- discharge current) are not read: Alpha2MQTT's author saw the charge - -- value stay at 0 and the discharge value at twice the pack's rating, - -- so they are not trusted as live limits. senalse describes 0x0111 as - -- the BMS's present maximum charge current (x 0.1 A); the two sources - -- disagree, and hardware has to settle it before Core relies on it. - local cell_regs = probe_read(269, 4, "holding") - if cell_regs then - local low_c = host.decode_i16(cell_regs[1]) * 0.1 - local high_c = host.decode_i16(cell_regs[4]) * 0.1 - if low_c >= -40 and low_c <= 100 then + local low_c = plausible_temp(host.decode_i16(bat_regs[14]) * 0.1) -- 0x010D + local high_c = plausible_temp(host.decode_i16(bat_regs[17]) * 0.1) -- 0x0110 + if low_c ~= nil then host.emit_metric("battery_cell_temp_min_c", low_c) end - if high_c >= -40 and high_c <= 100 then + if high_c ~= nil then host.emit_metric("battery_cell_temp_max_c", high_c) end end -- ---- Meter ---- - - -- Phase voltage: 0x0026=38, U16 × 0.1V - local lv_regs = probe_read(38, 1, "holding") - local l1_v = 0 - if lv_regs then - l1_v = lv_regs[1] * 0.1 - end - - -- Phase current: 0x0027=39, U16 × 0.1A - local la_regs = probe_read(39, 1, "holding") - local l1_a = 0 - if la_regs then - l1_a = la_regs[1] * 0.1 + -- + -- 0x0017-0x0022 in one read (the grid meter's running data): + -- 0x0017 current of A phase S16 x 0.1 A + -- 0x001A grid frequency U16 x 0.01 Hz + -- 0x0021 total active power S32, 1 W + -- Total power is positive when drawing from the grid and negative when + -- feeding it (Alpha2MQTT: "Minus = feeding, Positive = drawing"; evcc + -- and senalse read it the same way), which is the site convention, so it + -- is passed through. The vendor's table gives no sign. + -- + -- Phase voltage (0x0014) is left out: the vendor says 1 V per bit, + -- Alpha2MQTT's author read 2421 for 242.1 V, and the sources do not + -- agree on the scale. + local m_regs = probe_read(0x0017, 12, "holding") + if m_regs then + host.emit("meter", { + W = host.decode_i32_be(m_regs[11], m_regs[12]), -- 0x0021 + L1_A = host.decode_i16(m_regs[1]) * 0.1, -- 0x0017 + Hz = m_regs[4] * 0.01, -- 0x001A + }) end - -- Grid power: 0x0028=40, I16, W (positive=import) - local mw_regs = probe_read(40, 1, "holding") - local meter_w = 0 - if mw_regs then - meter_w = host.decode_i16(mw_regs[1]) - end - - -- Emit Meter telemetry - host.emit("meter", { - W = meter_w, - L1_V = l1_v, - L1_A = l1_a, - Hz = hz, - }) - return 5000 end diff --git a/drivers/lua/kstar.lua b/drivers/lua/kstar.lua index e63fb42..dd22cc1 100644 --- a/drivers/lua/kstar.lua +++ b/drivers/lua/kstar.lua @@ -1,8 +1,18 @@ -- KSTAR KSE Series Inverter Driver -- Emits: PV, Battery, Meter --- Register type: HOLDING (FC 0x03) +-- Register type: INPUT (FC 0x04) -- Port: 502 -- Community tier (untested) +-- +-- Register map: KSTAR "Hybrid Inverter MODBUS RS485 Communication Protocol" +-- V2.9.1 (2024-07-21, document SFT-KSE-001), table 3.1 "Inverter basic +-- information", read-only input registers from 3000. Its model table +-- (3.1.5) covers the KSE single-phase models, the BluE-S 3680D/5000D/6000D +-- (and M1) and the E8KT/E10KT/E12KT three-phase models. Signs, which the +-- vendor does not state, are taken from davidrapan/ha-solarman +-- kstar_hybrid.yaml; addresses and scales agree with it and with +-- StephanJoubert/home_assistant_solarman kstar_hybrid.yaml (written from +-- V2.5). No code was copied. -- No control code has been written for this inverter yet: driver_command -- only refuses. It says read_only so FTW and the catalog tell the owner @@ -13,7 +23,7 @@ DRIVER = { id = "kstar", name = "KSTAR inverter", manufacturer = "KSTAR", - version = "1.2.0", + version = "1.3.0", protocols = { "modbus" }, capabilities = { "pv", "battery", "meter" }, read_only = true, @@ -28,13 +38,21 @@ PROTOCOL = "modbus" -- nothing at all, which is worse than reporting one field less. So stop asking -- once a register has proved it is not there. Three tries, because one failure -- proves nothing -- the link may just have been slow. +-- +-- A short reply counts as a failure: every register asked for must be there, +-- or a decode further down would do arithmetic on nil. local GIVE_UP_AFTER = 3 local read_failures = {} local function probe_read(addr, count, kind) if (read_failures[addr] or 0) >= GIVE_UP_AFTER then return nil end local ok, regs = pcall(host.modbus_read, addr, count, kind) - if ok and regs and regs[1] ~= nil then + if ok and regs then + for i = 1, count do + if regs[i] == nil then ok = false break end + end + end + if ok and regs then read_failures[addr] = nil return regs end @@ -48,121 +66,131 @@ local function probe_read(addr, count, kind) return nil end +local function plausible_temp(c) + if c < -40 or c > 100 then return nil end + return c +end + +-- Inverter model, input 3045, KSTAR table 3.1.5: 0x00-0x1F are the +-- single-phase KSE and BluE-S models, 0x20-0x2F the three-phase ones. The +-- S and T phase meter registers (3101-3108) are "only for three phase +-- model". The model does not change, so it is read until it answers once. +-- nil until known; "single", "three", or "unknown" for a code outside the +-- table. +local phases = nil + +local function detect_phases() + if phases ~= nil then return phases end + local regs = probe_read(3045, 1, "input") + if not regs then return nil end + local code = regs[1] + if code <= 0x1F then + phases = "single" + elseif code <= 0x2F then + phases = "three" + else + phases = "unknown" + host.log("warn", string.format( + "KSTAR: inverter model code 0x%02X is not in KSTAR's model table; " .. + "grid meter left out", code)) + end + return phases +end + function driver_init(config) host.set_make("KSTAR") end function driver_poll() -- ---- PV ---- - - -- PV1 voltage: 28, U16 × 0.1V; PV1 current: 29, U16 × 0.1A - local pv1_regs = probe_read(28, 2, "holding") - local mppt1_v, mppt1_a = 0, 0 - if pv1_regs then - mppt1_v = pv1_regs[1] * 0.1 - mppt1_a = pv1_regs[2] * 0.1 + -- + -- 3000-3025 in one read: + -- 3000 PV1 input voltage U16 x 0.1 V + -- 3012 PV1 input current S16 x 0.01 A + -- 3024 PV1 input power S16, 1 W + -- 3025 PV2 input power S16, 1 W + local pv_regs = probe_read(3000, 26, "input") + if pv_regs then + local pv_w = host.decode_i16(pv_regs[25]) + host.decode_i16(pv_regs[26]) + host.emit("pv", { + W = -pv_w, -- generation is negative (site convention) + mppt1_v = pv_regs[1] * 0.1, + mppt1_a = host.decode_i16(pv_regs[13]) * 0.01, + }) end - -- PV power: 30, U16, W - local pvw_regs = probe_read(30, 1, "holding") - local pv_w = 0 - if pvw_regs then - pv_w = pvw_regs[1] - end - - -- Grid frequency: 18, U16 × 0.01Hz - local hz_regs = probe_read(18, 1, "holding") - local hz = 0 - if hz_regs then - hz = hz_regs[1] * 0.01 - end - - -- Emit PV telemetry (W always negative for generation) - host.emit("pv", { - W = -pv_w, - mppt1_v = mppt1_v, - mppt1_a = mppt1_a, - }) - -- ---- Battery ---- - - -- Battery power: 50, I16, W (positive=charge, negative=discharge) - local bw_regs = probe_read(50, 1, "holding") - local bat_w = 0 - if bw_regs then - bat_w = host.decode_i16(bw_regs[1]) - end - - -- Battery SoC: 54, U16, % - local bsoc_regs = probe_read(54, 1, "holding") - local bat_soc = 0 - if bsoc_regs then - bat_soc = bsoc_regs[1] / 100 -- percent to fraction - end - - -- Temperatures: INPUT registers 3055..3067 in one read. 3055 is the - -- inverter radiator, 3067 the battery; both I16 x 0.1 C. Source, for - -- addresses and scales only: davidrapan/ha-solarman - -- inverter_definitions/kstar_hybrid.yaml, written from KSTAR's Hybrid - -- Inverter Modbus V2.9.1 (2024-07-21). That map puts every reading in - -- input registers 3000 and up, not in the holding registers read above; - -- those need their own check against hardware. 3056 is the battery - -- converter's heatsink, not the battery, and is not used. The map has - -- no live BMS charge or discharge limit: 3078/3079 are percent - -- settings. - local temp_regs = probe_read(3055, 13, "input") - local bat_temp_c, inverter_c = nil, nil - if temp_regs then - local c = host.decode_i16(temp_regs[13]) * 0.1 - if c >= -40 and c <= 100 then bat_temp_c = c end - c = host.decode_i16(temp_regs[1]) * 0.1 - if c >= -40 and c <= 100 then inverter_c = c end - end - - -- Emit Battery telemetry - host.emit("battery", { - W = bat_w, - SoC_nom_fract = bat_soc, - temperature_C = bat_temp_c, - }) - if bat_temp_c ~= nil then - host.emit_metric("battery_temp_c", bat_temp_c) - end - if inverter_c ~= nil then - host.emit_metric("inverter_temp_c", inverter_c) + -- + -- 3055-3067 in one read: + -- 3055 inverter radiator temperature S16 x 0.1 C + -- 3063 battery voltage U16 x 0.01 V + -- 3065 battery charge/discharge power S16, 1 W + -- 3066 battery SOC U16 x 0.1 % + -- 3067 battery temperature S16 x 0.1 C + -- 3056 is the battery converter's heatsink, not the battery, and is not + -- used. KSTAR does not give the sign of 3065. ha-solarman's KSTAR + -- profile counts it as power into the DC bus (its "Power losses" sensor + -- is PV + battery - inverter output), so positive is discharging, and + -- the driver negates it (site convention: charging is positive). + -- + -- 3070/3071 BAT_CHG_LIMIT_CURR / BAT_DISCHG_LIMIT_CURR (1 A) are not + -- sent as available power: the map does not say whether they come from + -- the BMS or move with it. 3078/3079 are percent settings. + local bat_regs = probe_read(3055, 13, "input") + if bat_regs then + local battery = { + W = -host.decode_i16(bat_regs[11]), -- 3065 + V = bat_regs[9] * 0.01, -- 3063 + } + local soc_raw = bat_regs[12] -- 3066 + if soc_raw <= 1000 then + battery.SoC_nom_fract = soc_raw / 1000 + end + local bat_temp_c = plausible_temp(host.decode_i16(bat_regs[13]) * 0.1) -- 3067 + battery.temperature_C = bat_temp_c + host.emit("battery", battery) + if bat_temp_c ~= nil then + host.emit_metric("battery_temp_c", bat_temp_c) + end + local inverter_c = plausible_temp(host.decode_i16(bat_regs[1]) * 0.1) -- 3055 + if inverter_c ~= nil then + host.emit_metric("inverter_temp_c", inverter_c) + end end -- ---- Meter ---- - - -- Grid power: 22, I16, W (positive=import) - local mw_regs = probe_read(22, 1, "holding") - local meter_w = 0 - if mw_regs then - meter_w = host.decode_i16(mw_regs[1]) - end - - -- Phase voltage: 10, U16 × 0.1V - local lv_regs = probe_read(10, 1, "holding") - local l1_v = 0 - if lv_regs then - l1_v = lv_regs[1] * 0.1 + -- + -- 3097-3108, four registers per phase (R, S, T): + -- 3097 grid voltage U16 x 0.1 V + -- 3098 grid frequency U16 x 0.01 Hz + -- 3099 meter current S16 x 0.001 A + -- 3100 meter power S16, 1 W + -- KSTAR does not give the sign of the meter power. ha-solarman negates + -- it "to match standard behavior of the other inverters" (import + -- positive), and an owner there reported the raw value negative while + -- importing. So the raw value is positive when exporting, and the + -- driver negates it. The current is sent as read; its sign is not + -- documented. + local p = detect_phases() + local m_regs = nil + if p == "single" then + m_regs = probe_read(3097, 4, "input") + elseif p == "three" then + m_regs = probe_read(3097, 12, "input") end - - -- Phase current: 11, U16 × 0.1A - local la_regs = probe_read(11, 1, "holding") - local l1_a = 0 - if la_regs then - l1_a = la_regs[1] * 0.1 + if m_regs then + local w = host.decode_i16(m_regs[4]) + if p == "three" then + w = w + host.decode_i16(m_regs[8]) + host.decode_i16(m_regs[12]) + end + host.emit("meter", { + W = -w, + L1_V = m_regs[1] * 0.1, + L1_A = host.decode_i16(m_regs[3]) * 0.001, + Hz = m_regs[2] * 0.01, + }) end - -- Emit Meter telemetry - host.emit("meter", { - W = meter_w, - L1_V = l1_v, - L1_A = l1_a, - Hz = hz, - }) - return 5000 end diff --git a/drivers/tests/invented-number-baseline.json b/drivers/tests/invented-number-baseline.json index 935e481..6ecec62 100644 --- a/drivers/tests/invented-number-baseline.json +++ b/drivers/tests/invented-number-baseline.json @@ -14,7 +14,6 @@ "abb_meter": 13, "acrel": 13, "acuvim": 8, - "alphaess": 10, "atmoce": 13, "carlo_gavazzi": 13, "chint": 13, @@ -26,7 +25,6 @@ "hello": 3, "janitza": 13, "kostal": 21, - "kstar": 9, "schneider_meter": 13, "siemens_pac": 13, "sigenergy": 5, diff --git a/drivers/tests/lua_harness/test_all_drivers.lua b/drivers/tests/lua_harness/test_all_drivers.lua index d1a2e1f..9e0322a 100644 --- a/drivers/tests/lua_harness/test_all_drivers.lua +++ b/drivers/tests/lua_harness/test_all_drivers.lua @@ -147,6 +147,9 @@ local function setup_modbus_data(driver_name) -- the driver reads the full hybrid map. String models report another code. input[4999] = 0x0E0E holding[4999] = 0x0E0E + -- KSTAR inverter model, input 3045: 0x00 is the single-phase KSE-2K, + -- so the driver knows which meter phases the device has. + input[3045] = 0x00 -- Sungrow status reg 13000 = 0 (not discharging) input[13000] = 0 holding[13000] = 0 @@ -186,6 +189,8 @@ local function setup_modbus_data(driver_name) -- *0.1/100 pattern 13022, -- Sungrow 37004, -- Huawei + 3066, -- KSTAR (input) + 258, -- AlphaESS (0x0102) } for _, a in ipairs(soc_50_addrs) do holding[a] = 50 @@ -296,8 +301,6 @@ local function setup_modbus_data(driver_name) 28, -- SolaX 33139, -- Solis 11038, -- FoxESS - 54, -- KSTAR - 36, -- AlphaESS 4248, -- unused by current SAJ map; harmless 1014, -- Growatt } diff --git a/drivers/tests/test_alphaess_battery_now.py b/drivers/tests/test_alphaess_battery_now.py index d5a55a4..7df53e8 100644 --- a/drivers/tests/test_alphaess_battery_now.py +++ b/drivers/tests/test_alphaess_battery_now.py @@ -4,8 +4,9 @@ highest (0x0110) cell temperature, I16 x 0.1 °C. They go to history as battery_cell_temp_min_c and battery_cell_temp_max_c. The block has no pack temperature, so `temperature_C` stays out of the battery stream, and the BMS -current registers 0x0111/0x0112 are not read: one integration's author saw -them stay at values that cannot be live limits. +current registers 0x0111/0x0112 are not used: one integration's author saw +them stay at values that cannot be live limits. The driver reads the block +0x0100-0x0126 in one go, so a failed read leaves all of it out. """ from __future__ import annotations @@ -86,14 +87,15 @@ def test_alphaess_reports_cell_temperature_range(): assert "battery.temperature_C" not in out assert "battery.temp_c" not in out assert "battery.available_charge_W" not in out - assert "reads.holding:273" not in out - assert "reads.holding:274" not in out + assert "battery.available_discharge_W" not in out + assert "metric.battery_charge_limit_a" not in out def test_alphaess_failed_cell_temperature_read_is_left_out(): - out = run({269: i16(-50), 272: 312}, fail=(269,)) + out = run({269: i16(-50), 272: 312}, fail=(0x0100,)) assert "metric.battery_cell_temp_min_c" not in out assert "metric.battery_cell_temp_max_c" not in out + assert not any(k.startswith("battery.") for k in out) def test_alphaess_out_of_range_cell_temperature_is_dropped(): diff --git a/drivers/tests/test_alphaess_map.py b/drivers/tests/test_alphaess_map.py new file mode 100644 index 0000000..f32277b --- /dev/null +++ b/drivers/tests/test_alphaess_map.py @@ -0,0 +1,166 @@ +"""AlphaESS reads the registers its own Modbus map gives, with the site's signs. + +AlphaESS's "Parameter address table" (protocol history up to V1.39) puts: + +- the grid meter's current of A phase at 0x0017 (S16 x 0.1 A), frequency at + 0x001A (U16 x 0.01 Hz) and total active power at 0x0021 (S32, 1 W), + positive when drawing from the grid (Alpha2MQTT, evcc, senalse); +- battery voltage at 0x0100 (x 0.1 V), SoC at 0x0102 (x 0.1 %) and battery + power at 0x0126 (S16, 1 W, "-: Charge, +: Discharge"); +- PV string voltage, current and power (U32) for strings 1 to 6 at + 0x041D-0x0434, four registers apart. + +Earlier releases read 0x0010-0x0028 as PV, battery and meter. In the +vendor's map those are grid meter energy counters, voltages and powers. +Each stream is sent only when its read answered, never as zeros. +""" + +from __future__ import annotations + +import subprocess +from pathlib import Path + +import pytest + +ROOT = Path(__file__).resolve().parents[2] +LUA = ROOT / "lua55" +HARNESS = ROOT / "drivers" / "tests" / "lua_harness" +DRIVER = ROOT / "drivers" / "lua" / "alphaess.lua" + +pytestmark = pytest.mark.skipif( + not LUA.exists(), reason="run make check to build ./lua55") + +REPORT = ''' +local function dump(prefix, t) + if not t then return end + for k, v in pairs(t) do + if type(v) ~= "table" then print(prefix .. k .. " " .. tostring(v)) end + end +end +local function last(t) return t and t[#t] or nil end +for _, der in ipairs({"pv", "battery", "meter"}) do + dump(der .. ".", last(host._emitted[der])) +end +for name, m in pairs(host._metrics) do + print("metric." .. name .. " " .. tostring(m.value)) +end +for _, c in ipairs(host._calls) do + if c.func == "modbus_read" then + print("read." .. tostring(c.args[3]) .. ":" .. tostring(c.args[1]) .. " " .. tostring(c.args[2])) + end +end +''' + + +def u16(value: int) -> int: + return value & 0xFFFF + + +def i32(value: int) -> tuple[int, int]: + raw = value & 0xFFFFFFFF + return raw >> 16, raw & 0xFFFF + + +def run(registers: dict[int, int], fail: tuple[int, ...] = (), + short: dict[int, int] | None = None) -> dict[str, str]: + lines = [f"host._modbus_registers.holding[{a}] = {v}" for a, v in registers.items()] + lines += [f'host._modbus_read_fail_addresses[{a}] = "Illegal Data Address"' for a in fail] + lines += [f"host._modbus_read_short_counts[{a}] = {n}" for a, n in (short or {}).items()] + script = ( + f'package.path = "{HARNESS}/?.lua;" .. package.path\n' + 'require("host_mock")\n' + "host.reset()\n" + + "\n".join(lines) + "\n" + f'dofile("{DRIVER}")\n' + "driver_init({})\n" + "local ok, err = pcall(driver_poll)\n" + 'if not ok then print("POLL_ERROR " .. tostring(err)) os.exit(1) end\n' + + REPORT) + result = subprocess.run([str(LUA), "-e", script], + capture_output=True, text=True, cwd=ROOT) + assert result.returncode == 0, result.stdout + result.stderr + return dict(line.split(" ", 1) + for line in result.stdout.strip().splitlines() if " " in line) + + +def num(out: dict[str, str], key: str) -> float: + assert key in out, f"{key} missing from {sorted(out)}" + return float(out[key]) + + +def meter_regs(total_w: int) -> dict[int, int]: + hi, lo = i32(total_w) + return {0x0017: u16(52), 0x001A: 5001, 0x0021: hi, 0x0022: lo} + + +@pytest.mark.parametrize("raw_w", [2300, -1500]) +def test_meter_power_is_total_active_power_at_0x0021(raw_w): + # Positive is drawing from the grid, the site convention: passed through. + out = run(meter_regs(raw_w)) + assert num(out, "meter.W") == raw_w + assert num(out, "meter.L1_A") == pytest.approx(5.2) + assert num(out, "meter.Hz") == pytest.approx(50.01) + # The sources disagree on the phase voltage's scale, so it is left out. + assert "meter.L1_V" not in out + assert out["read.holding:23"] == "12" + + +def test_meter_left_out_when_its_read_fails(): + out = run(meter_regs(2300), fail=(0x0017,)) + assert not any(k.startswith("meter.") for k in out) + + +@pytest.mark.parametrize("raw, site_w", [(-2000, 2000), (1500, -1500)]) +def test_battery_power_at_0x0126_with_site_sign(raw, site_w): + # AlphaESS: "-: Charge, +: Discharge". Site: charging is positive. + out = run({0x0100: 5120, 0x0102: 875, 0x0126: u16(raw)}) + assert num(out, "battery.W") == site_w + assert num(out, "battery.V") == pytest.approx(512.0) + assert num(out, "battery.SoC_nom_fract") == pytest.approx(0.875) + assert out["read.holding:256"] == "39" + + +def test_battery_soc_out_of_range_is_left_out(): + out = run({0x0100: 5120, 0x0102: 1001, 0x0126: 0}) + assert "battery.SoC_nom_fract" not in out + assert num(out, "battery.W") == 0 + + +def test_battery_left_out_when_its_read_fails(): + out = run({0x0100: 5120, 0x0102: 875, 0x0126: u16(-2000)}, fail=(0x0100,)) + assert not any(k.startswith("battery.") for k in out) + + +def test_battery_short_reply_is_a_failed_read(): + out = run({0x0100: 5120, 0x0102: 875, 0x0126: u16(-2000)}, short={0x0100: 10}) + assert not any(k.startswith("battery.") for k in out) + + +def test_pv_power_is_the_sum_of_the_string_powers(): + regs = { + 0x041D: 3500, 0x041E: 82, # PV1 350.0 V, 8.2 A + 0x041F: 0, 0x0420: 2870, # PV1 2870 W + 0x0423: 0, 0x0424: 1200, # PV2 1200 W + 0x042B: 1, 0x042C: 0, # PV4 65536 W: the high word counts + } + out = run(regs) + assert num(out, "pv.W") == -(2870 + 1200 + 65536) + assert num(out, "pv.mppt1_v") == pytest.approx(350.0) + assert num(out, "pv.mppt1_a") == pytest.approx(8.2) + assert out["read.holding:1053"] == "24" + + +def test_pv_left_out_when_its_read_fails(): + out = run({0x041D: 3500, 0x041F: 0, 0x0420: 2870}, fail=(0x041D,)) + assert not any(k.startswith("pv.") for k in out) + + +def test_nothing_is_sent_when_every_read_fails(): + out = run({}, fail=(0x0017, 0x0100, 0x041D)) + assert not any(k.split(".")[0] in ("pv", "battery", "meter") for k in out) + + +def test_old_map_registers_are_not_read(): + out = run({}) + for addr in (16, 18, 32, 33, 34, 36, 38, 39, 40): + assert f"read.holding:{addr}" not in out, addr diff --git a/drivers/tests/test_kstar_battery_now.py b/drivers/tests/test_kstar_battery_now.py index e56cded..5f07461 100644 --- a/drivers/tests/test_kstar_battery_now.py +++ b/drivers/tests/test_kstar_battery_now.py @@ -2,9 +2,11 @@ KSTAR's hybrid Modbus map (V2.9.1, as read by ha-solarman) holds the inverter radiator temperature in input register 3055 and the battery temperature in -3067, both I16 x 0.1 °C. The driver reads 3055..3067 in one go. A failed read -or a value outside -40..100 °C is left out, never sent as zero. The map has -no live BMS limit, so no `available_*` field is sent. +3067, both I16 x 0.1 °C. The driver reads 3055..3067 in one go, together +with the battery's voltage, power and SoC. A failed read or a value outside +-40..100 °C is left out, never sent as zero. The map does not say that its +charge and discharge current limits come from the BMS, so no `available_*` +field is sent. """ from __future__ import annotations @@ -93,8 +95,8 @@ def test_kstar_failed_temperature_read_is_left_out(): assert "battery.temp_c" not in out assert "metric.battery_temp_c" not in out assert "metric.inverter_temp_c" not in out - # The battery stream itself still goes out. - assert "battery.W" in out + # The whole block failed, so nothing from it goes out. + assert not any(k.startswith("battery.") for k in out) def test_kstar_out_of_range_temperature_is_dropped(): diff --git a/drivers/tests/test_kstar_map.py b/drivers/tests/test_kstar_map.py new file mode 100644 index 0000000..63e4f2c --- /dev/null +++ b/drivers/tests/test_kstar_map.py @@ -0,0 +1,181 @@ +"""KSTAR reads the input registers its own Modbus map gives, with the site's signs. + +KSTAR's Hybrid Inverter Modbus V2.9.1 (table 3.1, function 04H) puts: + +- PV1 voltage at 3000 (x 0.1 V), PV1 current at 3012 (S16 x 0.01 A), PV1 and + PV2 power at 3024 and 3025 (S16, 1 W); +- the inverter model at 3045 (table 3.1.5: 0x00-0x1F single phase, + 0x20-0x2F three phase); +- battery voltage at 3063 (x 0.01 V), power at 3065 (S16, 1 W) and SoC at + 3066 (x 0.1 %); +- per phase grid voltage, frequency, meter current and meter power at + 3097-3100 (R), 3101-3104 (S) and 3105-3108 (T), S and T "only for three + phase model". + +KSTAR gives no signs. ha-solarman negates the meter power to make import +positive, and counts battery power as power into the DC bus (positive while +discharging). The driver turns both into site signs. Earlier releases read +holding registers 10-54, which no source has. +""" + +from __future__ import annotations + +import subprocess +from pathlib import Path + +import pytest + +ROOT = Path(__file__).resolve().parents[2] +LUA = ROOT / "lua55" +HARNESS = ROOT / "drivers" / "tests" / "lua_harness" +DRIVER = ROOT / "drivers" / "lua" / "kstar.lua" + +pytestmark = pytest.mark.skipif( + not LUA.exists(), reason="run make check to build ./lua55") + +REPORT = ''' +local function dump(prefix, t) + if not t then return end + for k, v in pairs(t) do + if type(v) ~= "table" then print(prefix .. k .. " " .. tostring(v)) end + end +end +local function last(t) return t and t[#t] or nil end +for _, der in ipairs({"pv", "battery", "meter"}) do + dump(der .. ".", last(host._emitted[der])) +end +for name, m in pairs(host._metrics) do + print("metric." .. name .. " " .. tostring(m.value)) +end +local calls = {} +for _, c in ipairs(host._calls) do + if c.func == "modbus_read" then + local key = tostring(c.args[3]) .. ":" .. tostring(c.args[1]) + print("read." .. key .. " " .. tostring(c.args[2])) + calls[key] = (calls[key] or 0) + 1 + end +end +for key, n in pairs(calls) do print("calls." .. key .. " " .. n) end +''' + +SINGLE = 0x04 # KSE-5K-048S +THREE = 0x21 # E8KT + + +def u16(value: int) -> int: + return value & 0xFFFF + + +def run(registers: dict[int, int], fail: tuple[int, ...] = (), + polls: int = 1) -> dict[str, str]: + lines = [f"host._modbus_registers.input[{a}] = {v}" for a, v in registers.items()] + lines += [f'host._modbus_read_fail_addresses[{a}] = "Illegal Data Address"' for a in fail] + script = ( + f'package.path = "{HARNESS}/?.lua;" .. package.path\n' + 'require("host_mock")\n' + "host.reset()\n" + + "\n".join(lines) + "\n" + f'dofile("{DRIVER}")\n' + "driver_init({})\n" + f"for _ = 1, {polls} do\n" + " local ok, err = pcall(driver_poll)\n" + ' if not ok then print("POLL_ERROR " .. tostring(err)) os.exit(1) end\n' + "end\n" + + REPORT) + result = subprocess.run([str(LUA), "-e", script], + capture_output=True, text=True, cwd=ROOT) + assert result.returncode == 0, result.stdout + result.stderr + return dict(line.split(" ", 1) + for line in result.stdout.strip().splitlines() if " " in line) + + +def num(out: dict[str, str], key: str) -> float: + assert key in out, f"{key} missing from {sorted(out)}" + return float(out[key]) + + +def meter_regs(model: int, r_w: int, s_w: int = 0, t_w: int = 0) -> dict[int, int]: + return { + 3045: model, + 3097: 2304, 3098: 4998, 3099: u16(-5230), 3100: u16(r_w), + 3104: u16(s_w), 3108: u16(t_w), + } + + +@pytest.mark.parametrize("raw, site_w", [(1800, -1800), (-950, 950)]) +def test_single_phase_meter_power_with_site_sign(raw, site_w): + # KSTAR's raw meter power is positive when exporting; site: import positive. + out = run(meter_regs(SINGLE, raw, s_w=999, t_w=999)) + assert num(out, "meter.W") == site_w + assert num(out, "meter.L1_V") == pytest.approx(230.4) + assert num(out, "meter.Hz") == pytest.approx(49.98) + assert num(out, "meter.L1_A") == pytest.approx(-5.23) + # Single phase: only R is read; S and T are not summed in. + assert out["read.input:3097"] == "4" + + +def test_three_phase_meter_sums_the_phases(): + out = run(meter_regs(THREE, -500, -600, -700)) + assert num(out, "meter.W") == 1800 + assert out["read.input:3097"] == "12" + + +def test_unknown_model_sends_no_meter(): + out = run(meter_regs(0x40, 1800)) + assert not any(k.startswith("meter.") for k in out) + assert "read.input:3097" not in out + + +def test_model_read_failure_sends_no_meter_but_keeps_the_rest(): + regs = meter_regs(SINGLE, 1800) + regs.update({3063: 5230, 3065: 0, 3066: 500, 3024: 100, 3025: 0}) + out = run(regs, fail=(3045,)) + assert not any(k.startswith("meter.") for k in out) + assert "battery.W" in out + assert "pv.W" in out + + +def test_model_is_read_once(): + out = run(meter_regs(SINGLE, 1800), polls=3) + assert out["calls.input:3045"] == "1" + assert out["calls.input:3097"] == "3" + assert num(out, "meter.W") == -1800 + + +def test_meter_left_out_when_its_read_fails(): + out = run(meter_regs(SINGLE, 1800), fail=(3097,)) + assert not any(k.startswith("meter.") for k in out) + + +@pytest.mark.parametrize("raw, site_w", [(-2500, 2500), (1200, -1200)]) +def test_battery_power_at_3065_with_site_sign(raw, site_w): + # Raw positive is power into the DC bus (discharging); site: charging positive. + out = run({3063: 5230, 3065: u16(raw), 3066: 643, 3067: 215}) + assert num(out, "battery.W") == site_w + assert num(out, "battery.V") == pytest.approx(52.30) + assert num(out, "battery.SoC_nom_fract") == pytest.approx(0.643) + assert num(out, "battery.temperature_C") == pytest.approx(21.5) + assert out["read.input:3055"] == "13" + + +def test_battery_soc_out_of_range_is_left_out(): + out = run({3063: 5230, 3065: 0, 3066: 1001}) + assert "battery.SoC_nom_fract" not in out + + +def test_pv_reads_input_registers_from_3000(): + out = run({3000: 3805, 3012: 921, 3024: 2100, 3025: 1350}) + assert num(out, "pv.W") == -3450 + assert num(out, "pv.mppt1_v") == pytest.approx(380.5) + assert num(out, "pv.mppt1_a") == pytest.approx(9.21) + assert out["read.input:3000"] == "26" + + +def test_pv_left_out_when_its_read_fails(): + out = run({3000: 3805, 3024: 2100}, fail=(3000,)) + assert not any(k.startswith("pv.") for k in out) + + +def test_no_holding_registers_are_read(): + out = run(meter_regs(SINGLE, 1800)) + assert not any(k.startswith("read.holding:") for k in out) diff --git a/index.yaml b/index.yaml index 762fd25..3da2c58 100644 --- a/index.yaml +++ b/index.yaml @@ -75,14 +75,14 @@ drivers: size_bytes: 23895 sha256: "e38da421ba6e5d3ceed2e9c6b7fdd620537b34e63ca48da14ac1e42080b133d0" - name: "alphaess" - version: "1.2.0" + version: "1.3.0" tier: community protocol: modbus connectivity: local ders: [pv, battery, meter] control: false - size_bytes: 6394 - sha256: "f1bf71b8f0a1e1e76c416f84e8f1bd7b08cb84f31fbb249a7c85921a7159a74d" + size_bytes: 7450 + sha256: "49cd62736e64e798f9b23fa634c9a0d3cb8768d3429aa08727f7021ee2b5fc91" - name: "ambibox" version: "1.2.0" tier: core @@ -403,14 +403,14 @@ drivers: size_bytes: 17688 sha256: "a5ea16a0f5a3315487384589589e14a3c0ef0407339997a0251dc5b50039008e" - name: "kstar" - version: "1.2.0" + version: "1.3.0" tier: community protocol: modbus connectivity: local ders: [pv, battery, meter] control: false - size_bytes: 5508 - sha256: "1855663dd2c8f2a1c08eda1cd6af06f9f3391df0900b29a654c89229216d635f" + size_bytes: 7749 + sha256: "c9273b026ec6ec2457e17d2a5c709babd566ee376be225dfbd82a9803b6086d3" - name: "mennekes" version: "1.1.1" tier: community diff --git a/manifests/alphaess.yaml b/manifests/alphaess.yaml index 0d7ef07..99dc34a 100644 --- a/manifests/alphaess.yaml +++ b/manifests/alphaess.yaml @@ -1,5 +1,5 @@ name: "alphaess" -version: "1.2.0" +version: "1.3.0" tier: community author: "Sourceful Labs AB" protocol: modbus @@ -22,6 +22,22 @@ tested_devices: notes: "Community driver, untested" min_driver_version: "1.0.0" upstream_docs: + - url: "https://raw.githubusercontent.com/ramonvanraaij/ha-alphaess-modbus/main/docs/alphaess_modbus_register_parameter_list.pdf" + title: "AlphaESS Modbus parameter address table (household meter, battery and inverter blocks), copy in ramonvanraaij/ha-alphaess-modbus" + kind: register_map + url_stability: stable + - url: "https://raw.githubusercontent.com/ramonvanraaij/ha-alphaess-modbus/main/docs/alphaess_modbus_register_map_table.pdf" + title: "AlphaESS Household Register Map: register blocks per model, copy in ramonvanraaij/ha-alphaess-modbus" + kind: register_map + url_stability: stable + - url: "https://raw.githubusercontent.com/ramonvanraaij/ha-alphaess-modbus/main/docs/alphaess_modbus_protocol.pdf" + title: "AlphaESS Modbus_RTU/TCP Protocol, version history to V1.39, copy in ramonvanraaij/ha-alphaess-modbus" + kind: changelog + url_stability: stable + - url: "https://raw.githubusercontent.com/evcc-io/evcc/master/templates/definition/meter/alpha-ess-smile.yaml" + title: "evcc alpha-ess-smile template (grid, PV and battery registers and signs)" + kind: other + url_stability: stable - url: "https://raw.githubusercontent.com/dxoverdy/Alpha2MQTT/master/Alpha2MQTT/Definitions.h" title: "dxoverdy/Alpha2MQTT AlphaESS register definitions (battery block 0x0100-0x0130)" kind: register_map @@ -31,12 +47,12 @@ upstream_docs: kind: register_map url_stability: stable min_host_version: "2.0.0" -size_bytes: 6394 +size_bytes: 7450 dkb_id: "" -sha256: "f1bf71b8f0a1e1e76c416f84e8f1bd7b08cb84f31fbb249a7c85921a7159a74d" +sha256: "49cd62736e64e798f9b23fa634c9a0d3cb8768d3429aa08727f7021ee2b5fc91" signature: "" bytecode_sha256: "" bytecode_signature: "" bytecode_size: 0 -changelog: "" +changelog: "Read the grid meter, battery and PV from the registers in AlphaESS's current Modbus map, with site signs; send nothing for a read that failed." diff --git a/manifests/kstar.yaml b/manifests/kstar.yaml index 9290f56..f0ff81f 100644 --- a/manifests/kstar.yaml +++ b/manifests/kstar.yaml @@ -1,5 +1,5 @@ name: "kstar" -version: "1.2.0" +version: "1.3.0" tier: community author: "Sourceful Labs AB" protocol: modbus @@ -22,17 +22,21 @@ tested_devices: notes: "Community driver, untested" min_driver_version: "1.0.0" upstream_docs: + - url: "https://github.com/user-attachments/files/17555061/KSTAR.Hybrid.Inverter.Modbus.V2.9.1_2024.07.21.pdf" + title: "KSTAR Hybrid Inverter MODBUS RS485 Communication Protocol V2.9.1 (2024-07-21), from KSTAR support, attached to davidrapan/ha-solarman" + kind: register_map + url_stability: unknown - url: "https://raw.githubusercontent.com/davidrapan/ha-solarman/main/custom_components/solarman/inverter_definitions/kstar_hybrid.yaml" title: "davidrapan/ha-solarman KSTAR hybrid inverter register definitions (from KSTAR Hybrid Inverter Modbus V2.9.1)" kind: register_map url_stability: stable min_host_version: "2.0.0" -size_bytes: 5508 +size_bytes: 7749 dkb_id: "" -sha256: "1855663dd2c8f2a1c08eda1cd6af06f9f3391df0900b29a654c89229216d635f" +sha256: "c9273b026ec6ec2457e17d2a5c709babd566ee376be225dfbd82a9803b6086d3" signature: "" bytecode_sha256: "" bytecode_signature: "" bytecode_size: 0 -changelog: "" +changelog: "Read PV, battery and grid meter from KSTAR's input registers from 3000, with site signs; send nothing for a read that failed." diff --git a/support-status.json b/support-status.json index 4499dfb..a7d14b0 100644 --- a/support-status.json +++ b/support-status.json @@ -170,7 +170,7 @@ }, { "catalog_source": true, - "catalog_version": "1.2.0", + "catalog_version": "1.3.0", "driver_id": "alphaess", "targets": { "blixt-l1": { @@ -905,7 +905,7 @@ }, { "catalog_source": true, - "catalog_version": "1.2.0", + "catalog_version": "1.3.0", "driver_id": "kstar", "targets": { "blixt-l1": { From a429e8e87d4ad0a697d4bcb2fdf6a685ea113eae Mon Sep 17 00:00:00 2001 From: Fredrik Ahlgren Date: Sun, 22 Nov 2026 13:42:56 +0100 Subject: [PATCH 2/2] fix(alphaess, kstar): gate the battery, meter map and model codes Review fixes for the 1.3.0 map change. - Both: battery voltage and SoC both 0 means no pack is connected, so the battery stream and battery metrics are left out instead of an empty pack (docs/WRITING-A-DRIVER.md, "A hybrid inverter may have no battery"). KSTAR's inverter temperature still goes out. - alphaess: the current meter map and PV strings 4 to 6 are used only once 0x074E (Protocol Version, in the System info block that V1.20 added) answers. Its value is not used; it read 0 on a real system. Firmware where it never answers gets PV strings 1 to 3 and no meter. - kstar: only the model codes KSTAR's table 3.1.5 names (0-9, 11, 12, 14, 15, 17, 18 single phase; 32-34 three phase) get a meter; reserved codes get none. - Neither map has a flag that says a grid meter is fitted, so the meter is still sent without one; the code and CHANGELOG say 0 W is then ambiguous. Not verified on hardware. Refs srcfl/device-drivers#257 Co-Authored-By: Claude Opus 5.5 Signed-off-by: Fredrik Ahlgren --- CHANGELOG.md | 16 +++-- drivers/lua/alphaess.lua | 63 ++++++++++++++++--- drivers/lua/kstar.lua | 71 ++++++++++++++++------ drivers/tests/test_alphaess_battery_now.py | 6 +- drivers/tests/test_alphaess_map.py | 59 ++++++++++++++++-- drivers/tests/test_kstar_battery_now.py | 4 +- drivers/tests/test_kstar_map.py | 31 +++++++++- index.yaml | 8 +-- manifests/alphaess.yaml | 4 +- manifests/kstar.yaml | 4 +- 10 files changed, 215 insertions(+), 51 deletions(-) diff --git a/CHANGELOG.md b/CHANGELOG.md index 94c1d44..ba3afd0 100644 --- a/CHANGELOG.md +++ b/CHANGELOG.md @@ -20,8 +20,10 @@ hardware. releases read meter energy counters and voltages at 0x0010-0x0028 as PV, battery and meter values. The grid phase voltage is no longer sent: the sources disagree on its scale. 0x0111/0x0112 are still not used as live - BMS limits. Firmware on the 2020 map (protocol V1.17, meter at - 0x0000-0x0019) is not covered. + BMS limits. The meter and PV strings 4 to 6 are read only once 0x074E + (Protocol Version, in the System info block V1.20 added) answers; firmware + on the 2020 map (V1.17, meter at 0x0000-0x0019) gets PV strings 1 to 3 + and no meter. - **kstar 1.3.0** reads KSTAR's input registers (function 04H) from 3000, as KSTAR's Hybrid Inverter Modbus V2.9.1 gives them for the KSE, BluE-S and E-series three-phase models: PV at 3000-3025, battery voltage, power and @@ -29,8 +31,14 @@ hardware. meter at 3097-3108. KSTAR gives no signs; following ha-solarman, the meter power (positive when exporting) and the battery power (positive when discharging) are negated. The model at 3045 says whether the S and - T phases exist; an unknown model sends no meter. Earlier releases read - holding registers 10-54, which no source has. + T phases exist; a code KSTAR's model table does not name sends no meter. + Earlier releases read holding registers 10-54, which no source has. + +In both drivers, battery voltage and SoC both 0 means no pack is connected, +so the battery stream is left out rather than sent as an empty pack. +Neither vendor map has a flag that says a grid meter is fitted, so with no +meter both drivers send whatever the meter registers hold: 0 W there cannot +be told from a balanced site. ### fronius 2.3.0 diff --git a/drivers/lua/alphaess.lua b/drivers/lua/alphaess.lua index 7ace3d8..7e9dfc5 100644 --- a/drivers/lua/alphaess.lua +++ b/drivers/lua/alphaess.lua @@ -16,8 +16,10 @@ -- -- Older firmware: protocol V1.17 (2020) put the grid meter at -- 0x0000-0x0019 (total power at 0x0006) and the inverter temperature at --- 0x0429, where V1.39 has PV4. V1.19 (2020-10-20) changed the meter table. --- This driver follows the current map only. +-- 0x0429, where V1.39 has PV4. V1.19 (2020-10-20) changed the meter table +-- and V1.20 (2020-10-25) added the System info block, 0x0740-0x074E. The +-- driver uses the current meter and PV strings 4 to 6 only once 0x074E +-- answers (see detect_map below). -- No control code has been written for this inverter yet: driver_command -- only refuses. It says read_only so FTW and the catalog tell the owner @@ -78,23 +80,50 @@ local function plausible_temp(c) return c end +-- Which map the firmware speaks. 0x074E "Protocol Version" is in the +-- System info block that V1.20 added; the vendor's model table lists it for +-- every model. Its value is not used: Alpha2MQTT's register dump from a +-- real system shows it as 0. So the gate is whether it answers at all. +-- nil while asking; "current" once it answered; "old" after it failed +-- GIVE_UP_AFTER times. A firmware between V1.20 and V1.22, which changed the +-- inverter block again, cannot be told apart from a later one. +local map_version = nil + +local function detect_map() + if map_version ~= nil then return map_version end + if probe_read(0x074E, 1, "holding") then + map_version = "current" + elseif (read_failures[0x074E] or 0) >= GIVE_UP_AFTER then + map_version = "old" + host.log("warn", "AlphaESS: register 0x074E does not answer, so this " .. + "firmware predates protocol V1.20; grid meter and PV strings 4-6 " .. + "left out") + end + return map_version +end + function driver_init(config) host.set_make("AlphaESS") end function driver_poll() + local map = detect_map() + -- ---- PV ---- -- -- 0x041D-0x0434 in one read: per string voltage (U16 x 0.1 V), current -- (U16 x 0.1 A) and power (U32, 1 W), strings 1 to 6, four registers - -- apart. PV power is their sum. 0x0453 "Pv total power" is newer than - -- the 0x0400-0x0452 block the vendor lists for every model, so it is not - -- used. A PV meter for an AC-coupled inverter (0x00A1) is not added: - -- that inverter may have its own driver. - local pv_regs = probe_read(0x041D, 24, "holding") + -- apart. PV power is their sum. Strings 1 to 3 (0x041D-0x0428) sit in + -- the same place in V1.17; until the current map is confirmed only they + -- are read. 0x0453 "Pv total power" is newer than the 0x0400-0x0452 + -- block the vendor lists for every model, so it is not used. A PV meter + -- for an AC-coupled inverter (0x00A1) is not added: that inverter may + -- have its own driver. + local pv_count = (map == "current") and 24 or 12 + local pv_regs = probe_read(0x041D, pv_count, "holding") if pv_regs then local pv_w = 0 - for i = 3, 23, 4 do + for i = 3, pv_count - 1, 4 do pv_w = pv_w + host.decode_u32_be(pv_regs[i], pv_regs[i + 1]) end host.emit("pv", { @@ -123,7 +152,14 @@ function driver_poll() -- the BMS, and Alpha2MQTT's author saw the charge value stay at 0 and -- the discharge value at 100 A on a 50 A pack. A 0 would tell Core the -- battery may not charge. + -- + -- Voltage and SoC both 0 means no pack is connected, not an empty one + -- (docs/WRITING-A-DRIVER.md, "A hybrid inverter may have no battery"): + -- the battery stream and its metrics are left out. local bat_regs = probe_read(0x0100, 39, "holding") + if bat_regs and bat_regs[1] == 0 and bat_regs[3] == 0 then + bat_regs = nil + end if bat_regs then local battery = { W = -host.decode_i16(bat_regs[39]), -- 0x0126 @@ -159,7 +195,16 @@ function driver_poll() -- Phase voltage (0x0014) is left out: the vendor says 1 V per bit, -- Alpha2MQTT's author read 2421 for 242.1 V, and the sources do not -- agree on the scale. - local m_regs = probe_read(0x0017, 12, "holding") + -- + -- The map has no flag that says a meter is fitted. 0x0000 "Grid Meter + -- CT Enable" read 0 on a working system in Alpha2MQTT's dump, and + -- 0x0806 "Meter CT Select" only says CT or meter. So with no meter the + -- driver sends whatever these registers hold, and 0 W cannot be told + -- from a balanced site. Read only on the current map (see detect_map). + local m_regs = nil + if map == "current" then + m_regs = probe_read(0x0017, 12, "holding") + end if m_regs then host.emit("meter", { W = host.decode_i32_be(m_regs[11], m_regs[12]), -- 0x0021 diff --git a/drivers/lua/kstar.lua b/drivers/lua/kstar.lua index dd22cc1..83485ba 100644 --- a/drivers/lua/kstar.lua +++ b/drivers/lua/kstar.lua @@ -71,28 +71,46 @@ local function plausible_temp(c) return c end --- Inverter model, input 3045, KSTAR table 3.1.5: 0x00-0x1F are the --- single-phase KSE and BluE-S models, 0x20-0x2F the three-phase ones. The --- S and T phase meter registers (3101-3108) are "only for three phase --- model". The model does not change, so it is read until it answers once. --- nil until known; "single", "three", or "unknown" for a code outside the --- table. +-- Inverter model, input 3045, KSTAR table 3.1.5. Only the codes the table +-- names are used; the rest are marked "reserve", and a reserved code gets no +-- meter rather than a guess. The S and T phase meter registers (3101-3108) +-- are "only for three phase model". The model does not change, so it is read +-- until it answers once. +local MODEL_PHASES = { + [0] = "single", -- KSE-2K-048S + [1] = "single", -- KSE-3K-048S + [2] = "single", -- KSE-3.6K-048S + [3] = "single", -- KSE-4.6K-048S + [4] = "single", -- KSE-5K-048S + [5] = "single", -- KSE-3.6K-048 + [6] = "single", -- KSE-4.6K-048 + [7] = "single", -- KSE-5K-048 + [8] = "single", -- KSE-6K-048 + [9] = "single", -- BluE-S 3680D + [11] = "single", -- BluE-S 5000D + [12] = "single", -- BluE-S 6000D + [14] = "single", -- KSE-3K-048S M1 + [15] = "single", -- BluE-S 3680D M1 + [17] = "single", -- BluE-S 5000D M1 + [18] = "single", -- BluE-S 6000D M1 + [32] = "three", -- E10KT + [33] = "three", -- E8KT + [34] = "three", -- E12KT +} + +-- nil until known; "single", "three", or "unknown" for a code the table +-- does not name. local phases = nil local function detect_phases() if phases ~= nil then return phases end local regs = probe_read(3045, 1, "input") if not regs then return nil end - local code = regs[1] - if code <= 0x1F then - phases = "single" - elseif code <= 0x2F then - phases = "three" - else - phases = "unknown" + phases = MODEL_PHASES[regs[1]] or "unknown" + if phases == "unknown" then host.log("warn", string.format( - "KSTAR: inverter model code 0x%02X is not in KSTAR's model table; " .. - "grid meter left out", code)) + "KSTAR: inverter model code %d is not named in KSTAR's model " .. + "table; grid meter left out", regs[1])) end return phases end @@ -136,7 +154,21 @@ function driver_poll() -- 3070/3071 BAT_CHG_LIMIT_CURR / BAT_DISCHG_LIMIT_CURR (1 A) are not -- sent as available power: the map does not say whether they come from -- the BMS or move with it. 3078/3079 are percent settings. + -- + -- Voltage and SoC both 0 means no pack is connected, not an empty one + -- (docs/WRITING-A-DRIVER.md, "A hybrid inverter may have no battery"): + -- the battery stream and the battery temperature are left out. The + -- inverter temperature in the same read still goes out. local bat_regs = probe_read(3055, 13, "input") + if bat_regs then + local inverter_c = plausible_temp(host.decode_i16(bat_regs[1]) * 0.1) -- 3055 + if inverter_c ~= nil then + host.emit_metric("inverter_temp_c", inverter_c) + end + if bat_regs[9] == 0 and bat_regs[12] == 0 then -- 3063, 3066 + bat_regs = nil + end + end if bat_regs then local battery = { W = -host.decode_i16(bat_regs[11]), -- 3065 @@ -152,10 +184,6 @@ function driver_poll() if bat_temp_c ~= nil then host.emit_metric("battery_temp_c", bat_temp_c) end - local inverter_c = plausible_temp(host.decode_i16(bat_regs[1]) * 0.1) -- 3055 - if inverter_c ~= nil then - host.emit_metric("inverter_temp_c", inverter_c) - end end -- ---- Meter ---- @@ -171,6 +199,11 @@ function driver_poll() -- importing. So the raw value is positive when exporting, and the -- driver negates it. The current is sent as read; its sign is not -- documented. + -- + -- The map has no flag that says a meter or CT is fitted (3264 "CT Or + -- Meter" only says which, and the alarm table has no meter fault). So + -- with none fitted the driver sends whatever these registers hold, and + -- 0 W cannot be told from a balanced site. local p = detect_phases() local m_regs = nil if p == "single" then diff --git a/drivers/tests/test_alphaess_battery_now.py b/drivers/tests/test_alphaess_battery_now.py index 7df53e8..180555e 100644 --- a/drivers/tests/test_alphaess_battery_now.py +++ b/drivers/tests/test_alphaess_battery_now.py @@ -81,7 +81,7 @@ def num(out: dict[str, str], key: str) -> float: def test_alphaess_reports_cell_temperature_range(): - out = run({269: i16(-50), 272: 312}) + out = run({0x0100: 5120, 269: i16(-50), 272: 312}) assert num(out, "metric.battery_cell_temp_min_c") == pytest.approx(-5.0, abs=1e-3) assert num(out, "metric.battery_cell_temp_max_c") == pytest.approx(31.2, abs=1e-3) assert "battery.temperature_C" not in out @@ -92,13 +92,13 @@ def test_alphaess_reports_cell_temperature_range(): def test_alphaess_failed_cell_temperature_read_is_left_out(): - out = run({269: i16(-50), 272: 312}, fail=(0x0100,)) + out = run({0x0100: 5120, 269: i16(-50), 272: 312}, fail=(0x0100,)) assert "metric.battery_cell_temp_min_c" not in out assert "metric.battery_cell_temp_max_c" not in out assert not any(k.startswith("battery.") for k in out) def test_alphaess_out_of_range_cell_temperature_is_dropped(): - out = run({269: i16(-500), 272: 1500}) + out = run({0x0100: 5120, 269: i16(-500), 272: 1500}) assert "metric.battery_cell_temp_min_c" not in out assert "metric.battery_cell_temp_max_c" not in out diff --git a/drivers/tests/test_alphaess_map.py b/drivers/tests/test_alphaess_map.py index f32277b..1a1dfe1 100644 --- a/drivers/tests/test_alphaess_map.py +++ b/drivers/tests/test_alphaess_map.py @@ -13,6 +13,12 @@ Earlier releases read 0x0010-0x0028 as PV, battery and meter. In the vendor's map those are grid meter energy counters, voltages and powers. Each stream is sent only when its read answered, never as zeros. + +AlphaESS's protocol V1.17 (2020) had the meter at 0x0000-0x0019 and only +three PV strings. V1.19 changed the meter table and V1.20 added the System +info block (0x0740-0x074E). The driver uses the current meter and strings +4 to 6 only when 0x074E (Protocol Version) answers. Its value is not used: +it read 0 on a real system (Alpha2MQTT's register dump). """ from __future__ import annotations @@ -44,11 +50,15 @@ for name, m in pairs(host._metrics) do print("metric." .. name .. " " .. tostring(m.value)) end +local calls = {} for _, c in ipairs(host._calls) do if c.func == "modbus_read" then - print("read." .. tostring(c.args[3]) .. ":" .. tostring(c.args[1]) .. " " .. tostring(c.args[2])) + local key = tostring(c.args[3]) .. ":" .. tostring(c.args[1]) + print("read." .. key .. " " .. tostring(c.args[2])) + calls[key] = (calls[key] or 0) + 1 end end +for key, n in pairs(calls) do print("calls." .. key .. " " .. n) end ''' @@ -62,7 +72,7 @@ def i32(value: int) -> tuple[int, int]: def run(registers: dict[int, int], fail: tuple[int, ...] = (), - short: dict[int, int] | None = None) -> dict[str, str]: + short: dict[int, int] | None = None, polls: int = 1) -> dict[str, str]: lines = [f"host._modbus_registers.holding[{a}] = {v}" for a, v in registers.items()] lines += [f'host._modbus_read_fail_addresses[{a}] = "Illegal Data Address"' for a in fail] lines += [f"host._modbus_read_short_counts[{a}] = {n}" for a, n in (short or {}).items()] @@ -73,8 +83,10 @@ def run(registers: dict[int, int], fail: tuple[int, ...] = (), + "\n".join(lines) + "\n" f'dofile("{DRIVER}")\n' "driver_init({})\n" - "local ok, err = pcall(driver_poll)\n" - 'if not ok then print("POLL_ERROR " .. tostring(err)) os.exit(1) end\n' + f"for _ = 1, {polls} do\n" + " local ok, err = pcall(driver_poll)\n" + ' if not ok then print("POLL_ERROR " .. tostring(err)) os.exit(1) end\n' + "end\n" + REPORT) result = subprocess.run([str(LUA), "-e", script], capture_output=True, text=True, cwd=ROOT) @@ -164,3 +176,42 @@ def test_old_map_registers_are_not_read(): out = run({}) for addr in (16, 18, 32, 33, 34, 36, 38, 39, 40): assert f"read.holding:{addr}" not in out, addr + + +def test_no_battery_sends_no_battery_stream(): + # Voltage and SoC both 0: no pack on the DC bus, not an empty one. + out = run({0x0100: 0, 0x0102: 0, 0x0126: 0, 0x010D: 0, 0x0110: 0}) + assert not any(k.startswith("battery.") for k in out) + assert "metric.battery_cell_temp_min_c" not in out + assert "metric.battery_cell_temp_max_c" not in out + assert "pv.W" in out + + +def test_empty_pack_with_a_voltage_is_still_sent(): + out = run({0x0100: 4600, 0x0102: 0, 0x0126: 0}) + assert num(out, "battery.SoC_nom_fract") == 0 + assert num(out, "battery.V") == pytest.approx(460.0) + + +def test_current_map_is_confirmed_once_by_the_protocol_version_register(): + out = run(meter_regs(2300), polls=3) + assert out["calls.holding:1870"] == "1" # 0x074E + assert out["calls.holding:23"] == "3" + assert num(out, "meter.W") == 2300 + + +def test_old_firmware_without_system_info_gets_no_meter_and_three_strings(): + regs = meter_regs(2300) + regs.update({0x041D: 3500, 0x041E: 82, 0x041F: 0, 0x0420: 2870, + 0x0429: 250, 0x042B: 1, 0x042C: 0, + 0x0100: 5120, 0x0102: 875, 0x0126: 0}) + out = run(regs, fail=(0x074E,), polls=5) + assert not any(k.startswith("meter.") for k in out) + assert "read.holding:23" not in out + # PV1-PV3 sit where they always have; 0x0429 was the inverter + # temperature in V1.17, so strings 4 to 6 are not read. + assert out["read.holding:1053"] == "12" + assert num(out, "pv.W") == -2870 + assert "battery.W" in out + # The probe is bounded: three tries, then left alone. + assert out["calls.holding:1870"] == "3" diff --git a/drivers/tests/test_kstar_battery_now.py b/drivers/tests/test_kstar_battery_now.py index 5f07461..0b25fd5 100644 --- a/drivers/tests/test_kstar_battery_now.py +++ b/drivers/tests/test_kstar_battery_now.py @@ -81,7 +81,7 @@ def num(out: dict[str, str], key: str) -> float: def test_kstar_reports_battery_and_inverter_temperature(): - out = run({3055: 455, 3067: i16(-50)}) + out = run({3055: 455, 3063: 5230, 3067: i16(-50)}) assert num(out, "battery.temperature_C") == pytest.approx(-5.0, abs=1e-3) assert num(out, "metric.battery_temp_c") == pytest.approx(-5.0, abs=1e-3) assert num(out, "metric.inverter_temp_c") == pytest.approx(45.5, abs=1e-3) @@ -100,7 +100,7 @@ def test_kstar_failed_temperature_read_is_left_out(): def test_kstar_out_of_range_temperature_is_dropped(): - out = run({3055: 455, 3067: 1500}) + out = run({3055: 455, 3063: 5230, 3067: 1500}) assert "battery.temperature_C" not in out assert "metric.battery_temp_c" not in out assert num(out, "metric.inverter_temp_c") == pytest.approx(45.5, abs=1e-3) diff --git a/drivers/tests/test_kstar_map.py b/drivers/tests/test_kstar_map.py index 63e4f2c..8297d60 100644 --- a/drivers/tests/test_kstar_map.py +++ b/drivers/tests/test_kstar_map.py @@ -120,12 +120,39 @@ def test_three_phase_meter_sums_the_phases(): assert out["read.input:3097"] == "12" -def test_unknown_model_sends_no_meter(): - out = run(meter_regs(0x40, 1800)) +@pytest.mark.parametrize("code", [10, 13, 16, 19, 31, 35, 47, 0x40]) +def test_unlisted_model_sends_no_meter(code): + # Table 3.1.5 marks 10, 13, 16, 19-31 and 35-47 "reserve". + out = run(meter_regs(code, 1800)) assert not any(k.startswith("meter.") for k in out) assert "read.input:3097" not in out +@pytest.mark.parametrize("code, count", [ + (0, "4"), (9, "4"), (11, "4"), (14, "4"), (18, "4"), + (32, "12"), (33, "12"), (34, "12"), +]) +def test_listed_models_read_their_phases(code, count): + out = run(meter_regs(code, 1800)) + assert out["read.input:3097"] == count + assert "meter.W" in out + + +def test_no_battery_sends_no_battery_stream(): + # Voltage and SoC both 0: no pack, not an empty one. + out = run({3055: 455, 3063: 0, 3065: 0, 3066: 0, 3067: 0}) + assert not any(k.startswith("battery.") for k in out) + assert "metric.battery_temp_c" not in out + # The inverter's own temperature is not the battery's. + assert num(out, "metric.inverter_temp_c") == pytest.approx(45.5) + + +def test_empty_pack_with_a_voltage_is_still_sent(): + out = run({3063: 4610, 3065: 0, 3066: 0}) + assert num(out, "battery.SoC_nom_fract") == 0 + assert num(out, "battery.V") == pytest.approx(46.10) + + def test_model_read_failure_sends_no_meter_but_keeps_the_rest(): regs = meter_regs(SINGLE, 1800) regs.update({3063: 5230, 3065: 0, 3066: 500, 3024: 100, 3025: 0}) diff --git a/index.yaml b/index.yaml index 3da2c58..6facac3 100644 --- a/index.yaml +++ b/index.yaml @@ -81,8 +81,8 @@ drivers: connectivity: local ders: [pv, battery, meter] control: false - size_bytes: 7450 - sha256: "49cd62736e64e798f9b23fa634c9a0d3cb8768d3429aa08727f7021ee2b5fc91" + size_bytes: 9564 + sha256: "ad6de3206098e063f6e2344b35a4ff836c20d69549777aaf6a9b3c68eca4545d" - name: "ambibox" version: "1.2.0" tier: core @@ -409,8 +409,8 @@ drivers: connectivity: local ders: [pv, battery, meter] control: false - size_bytes: 7749 - sha256: "c9273b026ec6ec2457e17d2a5c709babd566ee376be225dfbd82a9803b6086d3" + size_bytes: 9159 + sha256: "b13d4a0e1d8a7a41e0f3fd175c60159b1324273c066167cf7903fc0a73c521d0" - name: "mennekes" version: "1.1.1" tier: community diff --git a/manifests/alphaess.yaml b/manifests/alphaess.yaml index 99dc34a..acd24e9 100644 --- a/manifests/alphaess.yaml +++ b/manifests/alphaess.yaml @@ -47,9 +47,9 @@ upstream_docs: kind: register_map url_stability: stable min_host_version: "2.0.0" -size_bytes: 7450 +size_bytes: 9564 dkb_id: "" -sha256: "49cd62736e64e798f9b23fa634c9a0d3cb8768d3429aa08727f7021ee2b5fc91" +sha256: "ad6de3206098e063f6e2344b35a4ff836c20d69549777aaf6a9b3c68eca4545d" signature: "" bytecode_sha256: "" diff --git a/manifests/kstar.yaml b/manifests/kstar.yaml index f0ff81f..6a0232a 100644 --- a/manifests/kstar.yaml +++ b/manifests/kstar.yaml @@ -31,9 +31,9 @@ upstream_docs: kind: register_map url_stability: stable min_host_version: "2.0.0" -size_bytes: 7749 +size_bytes: 9159 dkb_id: "" -sha256: "c9273b026ec6ec2457e17d2a5c709babd566ee376be225dfbd82a9803b6086d3" +sha256: "b13d4a0e1d8a7a41e0f3fd175c60159b1324273c066167cf7903fc0a73c521d0" signature: "" bytecode_sha256: ""