diff --git a/CHANGELOG.md b/CHANGELOG.md index 96e328c..750082e 100644 --- a/CHANGELOG.md +++ b/CHANGELOG.md @@ -2,6 +2,46 @@ ## [Unreleased] +### fronius 2.3.0 + +Battery power, voltage and SoC now come from the registers Fronius's GEN24 +and Verto storage maps give them (register map bundle 1.2.7-2, float maps). +Not yet checked on hardware (srcfl/device-drivers#260). + +- **Where the battery is.** Earlier releases read model 124 at fixed + addresses that assume a model 160 with two inputs. With storage, Fronius's + model 160 has two more, for the battery, so those reads landed inside + model 160's battery blocks. The driver now reads model 160's header, + learns its length, and finds model 124 directly after it. +- **Battery power** is the charge input's DC power minus the discharge + input's (the last two blocks of model 160, "StCha" and "StDisCha"), + positive when charging. Earlier releases took it from OutWRte and InWRte + times WChaMax, which are rate setpoints and a rating, not a measurement. +- **Voltage** is the larger of the two inputs' DC voltage (before firmware + 1.31 only the active input carries it), and is left out when both read 0. + **SoC** is model 124's ChaState with its scale factor. +- **No storage, no battery.** Model 124 exists only with storage. Without it + the driver sends no battery, where earlier releases sent 0 W, 0 V and 0 %. +- **Floats.** The float decoder works on the 16-bit halves. It joined the + words into one 32-bit number first, so on 32-bit Lua every float came out + negative (FTW and Blixt L1 use 64-bit integers and were not affected). NaN + and infinity are now left out instead of sent as 0. +- **Failed reads are left out.** PV is sent only when DC power answered, and + each other PV field and metric only when its own read did. The MPPT values + come from one read of model 160, with the scale factors that go with them. + `fronius` leaves `invented-number-baseline.json` (10 to 0). +- **PV power with storage** is the sum of the MPPT blocks before the + battery blocks, as evcc's GEN24 template reads it. Fronius's map does not + say whether model 113's DC power includes the battery input, so a 3 kW + discharge could have shown as 3 kW of sun. Model 113's DC power is used + only where there is no battery input. +- **A battery fitted later is found.** While no storage model is known the + driver looks for it again every five minutes, and at once when model + 160's length changes. +- **Not changed.** In the int+SF setting model 160 starts at 40254; the + driver reads only the float maps, so it now sends no DC input or battery + values there rather than wrong ones. + ### ferroamp_modbus 2.2.2 A float that answers NaN or infinity is now left out instead of sent as 0 diff --git a/SUPPORT_STATUS.md b/SUPPORT_STATUS.md index 2948ba6..d020626 100644 --- a/SUPPORT_STATUS.md +++ b/SUPPORT_STATUS.md @@ -58,8 +58,8 @@ Catalog source is not proof that a target can install or run a driver. | ferroamp_modbus | 2.2.2 | blixt-l1 | not_assessed | — | not_recorded | not_assessed | | foxess_h3_smart | 0.10.0 | ftw-core | not_assessed | — | not_recorded | not_assessed | | foxess_h3_smart | 0.10.0 | blixt-l1 | not_assessed | — | not_recorded | not_assessed | -| fronius | 2.2.0 | ftw-core | not_assessed | — | not_recorded | not_assessed | -| fronius | 2.2.0 | blixt-l1 | not_assessed | — | not_recorded | not_assessed | +| fronius | 2.3.0 | ftw-core | not_assessed | — | not_recorded | not_assessed | +| fronius | 2.3.0 | blixt-l1 | not_assessed | — | not_recorded | not_assessed | | fronius_api | 1.0.2 | ftw-core | not_assessed | — | not_recorded | not_assessed | | fronius_api | 1.0.2 | blixt-l1 | not_assessed | — | not_recorded | not_assessed | | fronius_smart_meter | 2.1.3 | ftw-core | not_assessed | — | not_recorded | not_assessed | diff --git a/devices.yaml b/devices.yaml index 346a0c4..75cee1c 100644 --- a/devices.yaml +++ b/devices.yaml @@ -419,7 +419,7 @@ manufacturers: protocols: - protocol: modbus driver: "fronius" - version: "2.2.0" + version: "2.3.0" ders: [battery, meter, pv] control: false firmware_versions: "" @@ -430,7 +430,7 @@ manufacturers: protocols: - protocol: modbus driver: "fronius" - version: "2.2.0" + version: "2.3.0" ders: [battery, meter, pv] control: false firmware_versions: "" @@ -441,7 +441,7 @@ manufacturers: protocols: - protocol: modbus driver: "fronius" - version: "2.2.0" + version: "2.3.0" ders: [battery, meter, pv] control: false firmware_versions: "" @@ -452,7 +452,7 @@ manufacturers: protocols: - protocol: modbus driver: "fronius" - version: "2.2.0" + version: "2.3.0" ders: [battery, meter, pv] control: false firmware_versions: "" @@ -463,7 +463,7 @@ manufacturers: protocols: - protocol: modbus driver: "fronius" - version: "2.2.0" + version: "2.3.0" ders: [battery, meter, pv] control: false firmware_versions: "" @@ -496,7 +496,7 @@ manufacturers: protocols: - protocol: modbus driver: "fronius" - version: "2.2.0" + version: "2.3.0" ders: [battery, meter, pv] control: false firmware_versions: "" diff --git a/drivers/lua/fronius.lua b/drivers/lua/fronius.lua index 23ca3a4..4bc30c6 100644 --- a/drivers/lua/fronius.lua +++ b/drivers/lua/fronius.lua @@ -15,7 +15,7 @@ DRIVER = { id = "fronius", name = "Fronius GEN24", manufacturer = "Fronius", - version = "2.2.0", + version = "2.3.0", protocols = { "modbus" }, capabilities = { "pv", "battery" }, read_only = true, @@ -65,50 +65,63 @@ end -- Decode IEEE 754 single-precision float from two u16 registers, -- big-endian word order: hi = first register, lo = second. --- Treats NaN / ±Inf (SunSpec "not implemented" sentinel 0x7FC00000) as 0. +-- +-- Works on the 16-bit halves (docs/WRITING-A-DRIVER.md, "Numbers"). Earlier +-- versions joined the words into one 32-bit number and compared it with +-- 0x80000000, which is negative where Lua integers are 32 bits, so every +-- float came out negative there (the harness, and any 32-bit host). FTW and +-- Blixt L1 use 64-bit integers and were not affected. ferroamp_modbus had the +-- same fault (srcfl/device-drivers#254). +-- +-- NaN and infinity give nil. Fronius answers NaN (0x7FC00000) for a point it +-- does not support, and earlier versions turned that into 0, a reading +-- nobody took. local function decode_f32_be(hi, lo) - local bits = (hi % 0x10000) * 0x10000 + (lo % 0x10000) - if bits == 0 then return 0 end - local sign = (bits >= 0x80000000) and -1 or 1 - local exp = math.floor(bits / 0x800000) % 0x100 - local frac = bits % 0x800000 - if exp == 0xFF then return 0 end - if exp == 0 then return sign * frac * 2 ^ -149 end - return sign * (1 + frac / 0x800000) * 2 ^ (exp - 127) -end - --- A temperature from two float32 registers (high word first), or nil. --- decode_f32_be above turns NaN into 0, and Fronius answers NaN --- (0x7FC00000) for a point it does not support, so a temperature read --- through it would pass for 0 °C. It also joins the words into one 32-bit --- number first, which flips the sign on a Lua build with 32-bit integers --- (docs/WRITING-A-DRIVER.md, "Numbers"). This one works on the 16-bit --- halves, refuses NaN and infinity, and drops anything outside -40..100 °C --- ("What a battery can do now"). -local function decode_temp_f32_be(hi, lo) if hi == nil or lo == nil then return nil end hi = hi % 0x10000 lo = lo % 0x10000 local sign = 1 if hi >= 0x8000 then sign = -1; hi = hi - 0x8000 end - local exponent = math.floor(hi / 128) - local mantissa = (hi % 128) * 65536 + lo + local exponent = math.floor(hi / 0x80) + local mantissa = (hi % 0x80) * 0x10000 + lo if exponent == 0xFF then return nil end - local v if exponent == 0 then - v = sign * mantissa * 2 ^ -149 - else - v = sign * (1 + mantissa / 0x800000) * 2 ^ (exponent - 127) + if mantissa == 0 then return 0 end + return sign * mantissa * 2 ^ -149 end - if v < -40 or v > 100 then return nil end + return sign * (1 + mantissa / 0x800000) * 2 ^ (exponent - 127) +end + +-- A temperature from two float32 registers (high word first), or nil when +-- the read failed, the device has no value, or it is outside -40..100 °C +-- ("What a battery can do now"). +local function decode_temp_f32_be(hi, lo) + local v = decode_f32_be(hi, lo) + if v == nil or v < -40 or v > 100 then return nil end return v end +-- SunSpec marks a point it does not implement with 0xFFFF in a uint16 and +-- 0x8000 in a scale factor (SunSpec information model). Both give nil. +local function sunspec_sf(raw) + if raw == nil or raw == 0x8000 then return nil end + local sf = host.decode_i16(raw) + if sf < -10 or sf > 10 then return nil end + return sf +end + +local function sunspec_u16(raw, sf) + if raw == nil or sf == nil or raw == 0xFFFF then return nil end + return apply_sf(raw, sf) +end + -- Turn a Lua array of u16s into an ASCII string, trimming NULs and spaces. -local function regs_to_string(regs, count) +-- `first` is the index of the first register (default 1). +local function regs_to_string(regs, count, first) if not regs then return "" end + first = first or 1 local s = "" - for i = 1, count do + for i = first, first + count - 1 do local r = regs[i] or 0 local hi = math.floor(r / 256) local lo = r % 256 @@ -152,6 +165,107 @@ local function probe_read(addr, count, kind) return nil end +---------------------------------------------------------------------------- +-- The SunSpec model chain: MPPT inputs and storage +-- +-- Source: Fronius's register map bundle 1.2.7-2 (QR-link/0024 in the +-- manifest), the float maps for GEN24 and Verto, with and without storage, +-- and the GEN24 Modbus manual 42,0410,2649. Fronius numbers registers from 1; +-- the wire address is one lower. +-- +-- Model 160 (Multiple MPPT) starts at register 40264, wire 40263 ("start +-- address for 'float' setting: 40263"). Its length L is 8 + 20 x N, one +-- 20-register block per DC input. With storage, N counts the MPPT trackers +-- plus two blocks for the battery: "StCha" (charge) and then "StDisCha" +-- (discharge), the last two. A GEN24 has N = 4 (L = 88); a Verto with three +-- trackers has N = 5 (L = 108); without storage N is the number of trackers. +-- +-- Model 124 (Basic Storage Control) "is only available for inverters with a +-- storage solution" and follows model 160 directly. Without storage the end +-- block (0xFFFF) is there instead, and it answers, so the driver learns there +-- is no battery without a failed read. Earlier versions read model 124 at +-- fixed addresses that assume a two-input model 160, which on a GEN24 with +-- storage are inside model 160's battery blocks. +-- +-- The int+SF maps start model 160 at 40254 and use a different inverter +-- model. This driver reads the float maps only; when model 160 is not at +-- 40264 it reads no DC input or battery values rather than guess. +---------------------------------------------------------------------------- + +local MPPT_ADDR = 40263 -- wire address of model 160's ID +local MAX_READ = 125 -- registers in one Modbus read + +local mppt_len = nil -- L of model 160, from its header +local mppt_missing = false -- model 160 is not where the float map puts it +local storage_addr = nil -- wire address of model 124's ID, with storage +local storage_checked = false +local mppt_logged = false + +-- A battery fitted after the driver started changes the chain: model 160 +-- grows by the two battery blocks and model 124 appears after it. So while +-- no storage model is known the driver looks again every five minutes, and +-- at once when model 160's own length no longer matches. That costs two +-- short reads every five minutes on an inverter without a battery. +local RECHECK_MS = 5 * 60 * 1000 +local checked_at = nil + +local function forget_models() + mppt_len = nil + mppt_missing = false + storage_addr = nil + storage_checked = false + checked_at = nil +end + +local function find_models() + if storage_addr == nil and checked_at ~= nil + and host.millis() - checked_at >= RECHECK_MS then + forget_models() + end + if mppt_len == nil and not mppt_missing then + local hdr = probe_read(MPPT_ADDR, 2, "holding") + if hdr == nil or hdr[2] == nil then + -- A model 160 that never answers is treated as absent. + if (read_failures[MPPT_ADDR] or 0) >= GIVE_UP_AFTER then + mppt_missing = true + checked_at = host.millis() + end + return + end + local len = hdr[2] + if hdr[1] == 160 and len >= 28 and (len - 8) % 20 == 0 + and len + 2 <= MAX_READ then + mppt_len = len + else + mppt_missing = true + checked_at = host.millis() + if not mppt_logged then + mppt_logged = true + host.log("info", string.format( + "Fronius: register 40264 holds model %d, not 160; reading no " .. + "DC input or battery values (is Modbus set to 'float'?)", hdr[1])) + end + return + end + end + if mppt_len ~= nil and not storage_checked then + local addr = MPPT_ADDR + 2 + mppt_len + local nxt = probe_read(addr, 2, "holding") + if nxt == nil or nxt[2] == nil then return end + storage_checked = true + checked_at = host.millis() + if nxt[1] == 124 and nxt[2] == 24 then storage_addr = addr end + end +end + +-- Offsets within one read of model 160 (index 1 = its ID). Module k's block +-- starts at index 11 + 20 x (k - 1): ID, IDStr (8 registers), DCA, DCV, DCW. +local function module_base(k) return 11 + 20 * (k - 1) end + +local function module_name(regs, k) + return regs_to_string(regs, 8, module_base(k) + 1) +end + function driver_init(config) host.set_make("Fronius") end @@ -174,53 +288,26 @@ function driver_poll() end end - -- ---------------------------------------------------------------- SFs - -- Scale factors live in separate i16 registers. - - local rated_w_sf = 0 - local rwsf_regs = probe_read(40135, 1, "holding") - if rwsf_regs then rated_w_sf = host.decode_i16(rwsf_regs[1]) end - - local mppt_a_sf = 0 - local masf_regs = probe_read(40265, 1, "holding") - if masf_regs then mppt_a_sf = host.decode_i16(masf_regs[1]) end - - local mppt_v_sf = 0 - local mvsf_regs = probe_read(40266, 1, "holding") - if mvsf_regs then mppt_v_sf = host.decode_i16(mvsf_regs[1]) end - - local max_charge_sf = 0 - local mcsf_regs = probe_read(40331, 1, "holding") - if mcsf_regs then max_charge_sf = host.decode_i16(mcsf_regs[1]) end - - local soc_sf = 0 - local socsf_regs = probe_read(40335, 1, "holding") - if socsf_regs then soc_sf = host.decode_i16(socsf_regs[1]) end - - local bat_v_sf = 0 - local bvsf_regs = probe_read(40337, 1, "holding") - if bvsf_regs then bat_v_sf = host.decode_i16(bvsf_regs[1]) end - - local charge_rate_sf = 0 - local crsf_regs = probe_read(40338, 1, "holding") - if crsf_regs then charge_rate_sf = host.decode_i16(crsf_regs[1]) end + find_models() -- ---------------------------------------------------------------- PV - -- Inverter/AC values are SunSpec F32 BE pairs. + -- Inverter/AC values are SunSpec F32 BE pairs (model 113). - local ac_w = 0 + local ac_w = nil local acw_regs = probe_read(40091, 2, "holding") if acw_regs then ac_w = decode_f32_be(acw_regs[1], acw_regs[2]) end - local hz = 0 + local hz = nil local hz_regs = probe_read(40093, 2, "holding") if hz_regs then hz = decode_f32_be(hz_regs[1], hz_regs[2]) end - local lifetime_wh = 0 + local lifetime_wh = nil local le_regs = probe_read(40101, 2, "holding") if le_regs then lifetime_wh = decode_f32_be(le_regs[1], le_regs[2]) end - local dc_w = 0 + -- DCW, model 113 "DC Power". Used for PV only without a battery input + -- (see "PV power" below). + local dc_w = nil local dcw_regs = probe_read(40107, 2, "holding") if dcw_regs then dc_w = decode_f32_be(dcw_regs[1], dcw_regs[2]) end @@ -234,29 +321,79 @@ function driver_poll() local temp_regs = probe_read(40109, 2, "holding") if temp_regs then cabinet_c = decode_temp_f32_be(temp_regs[1], temp_regs[2]) end - -- Rated W: 40134, U16 raw × 10^rated_w_sf - local rated_w = 0 - local rw_regs = probe_read(40134, 1, "holding") - if rw_regs then rated_w = apply_sf(rw_regs[1], rated_w_sf) end - - -- MPPT1 A/V: 40282-40283, U16 each - local mppt1_a, mppt1_v = 0, 0 - local m1_regs = probe_read(40282, 2, "holding") - if m1_regs then - mppt1_a = apply_sf(m1_regs[1], mppt_a_sf) - mppt1_v = apply_sf(m1_regs[2], mppt_v_sf) + -- Rated W: WRtg and WRtg_SF, model 120 registers 40135-40136, one read. + local rated_w = nil + local rw_regs = probe_read(40134, 2, "holding") + if rw_regs then rated_w = sunspec_u16(rw_regs[1], sunspec_sf(rw_regs[2])) end + + -- Model 160 in one read, so the auto-scaled factors (DCA_SF, DCV_SF, + -- DCW_SF) come with the values they scale. MPPT 1 and 2 are the first + -- two blocks in every float map. + local mppt = nil + if mppt_len ~= nil then + mppt = probe_read(MPPT_ADDR, 2 + mppt_len, "holding") + if mppt and mppt[1] == 160 and mppt[2] ~= mppt_len then + -- Model 160 changed length, for example a battery was fitted: + -- find the chain again on the next poll. + forget_models() + mppt = nil + elseif mppt and (mppt[1] ~= 160 or mppt[2 + mppt_len] == nil) then + mppt = nil + end + end + + local mppt1_v, mppt1_a, mppt2_v, mppt2_a + local dca_sf, dcv_sf, dcw_sf, modules + if mppt then + dca_sf = sunspec_sf(mppt[3]) + dcv_sf = sunspec_sf(mppt[4]) + dcw_sf = sunspec_sf(mppt[5]) + modules = mppt[9] + if modules ~= nil and 8 + 20 * modules ~= mppt_len then modules = nil end + if modules ~= nil and modules >= 1 then + mppt1_a = sunspec_u16(mppt[module_base(1) + 9], dca_sf) + mppt1_v = sunspec_u16(mppt[module_base(1) + 10], dcv_sf) + end + if modules ~= nil and modules >= 2 then + mppt2_a = sunspec_u16(mppt[module_base(2) + 9], dca_sf) + mppt2_v = sunspec_u16(mppt[module_base(2) + 10], dcv_sf) + end + end + + -- The battery blocks: the last two of model 160, named "StCha" and + -- "StDisCha" in both storage maps. The names are checked, so a layout + -- the driver does not know gives no battery blocks. + local cha, dis = nil, nil + if mppt and modules ~= nil and modules >= 3 + and module_name(mppt, modules - 1):sub(1, 5) == "StCha" + and module_name(mppt, modules):sub(1, 8) == "StDisCha" then + cha, dis = modules - 1, modules end - -- MPPT2 A/V: 40302-40303, U16 each - local mppt2_a, mppt2_v = 0, 0 - local m2_regs = probe_read(40302, 2, "holding") - if m2_regs then - mppt2_a = apply_sf(m2_regs[1], mppt_a_sf) - mppt2_v = apply_sf(m2_regs[2], mppt_v_sf) + -- PV power. Fronius's map does not say whether model 113's DC power + -- includes the battery input, and evcc's fronius-gen24 template sums + -- the MPPT blocks instead. So with storage PV is the sum of the MPPT + -- blocks before the battery blocks; a 3 kW discharge then cannot show + -- as 3 kW of sun. Model 113's DC power is used only where there is no + -- battery input: no storage model after model 160, or a model 160 with + -- no battery blocks. With storage and no readable battery blocks, PV is + -- left out for that poll. + local pv_dc_w = nil + if cha ~= nil then + local sum = 0 + for k = 1, cha - 1 do + local w = sunspec_u16(mppt[module_base(k) + 11], dcw_sf) + if w == nil then sum = nil; break end + sum = sum + w + end + pv_dc_w = sum + elseif storage_addr == nil and (mppt_missing or storage_checked + or (mppt and modules ~= nil)) then + pv_dc_w = dc_w end -- Per-phase AC current: 40073, 40075, 40077 (F32 BE pairs) - local l1_a, l2_a, l3_a = 0, 0, 0 + local l1_a, l2_a, l3_a = nil, nil, nil local l1a_regs = probe_read(40073, 2, "holding") if l1a_regs then l1_a = decode_f32_be(l1a_regs[1], l1a_regs[2]) end local l2a_regs = probe_read(40075, 2, "holding") @@ -265,7 +402,7 @@ function driver_poll() if l3a_regs then l3_a = decode_f32_be(l3a_regs[1], l3a_regs[2]) end -- Per-phase AC voltage: 40085, 40087, 40089 (F32 BE pairs) - local l1_v, l2_v, l3_v = 0, 0, 0 + local l1_v, l2_v, l3_v = nil, nil, nil local l1v_regs = probe_read(40085, 2, "holding") if l1v_regs then l1_v = decode_f32_be(l1v_regs[1], l1v_regs[2]) end local l2v_regs = probe_read(40087, 2, "holding") @@ -273,96 +410,84 @@ function driver_poll() local l3v_regs = probe_read(40089, 2, "holding") if l3v_regs then l3_v = decode_f32_be(l3v_regs[1], l3v_regs[2]) end - -- Emit PV (dc_w magnitude → negative for generation, per site convention) - host.emit("pv", { - w = -dc_w, - mppt1_v = mppt1_v, - mppt1_a = mppt1_a, - mppt2_v = mppt2_v, - mppt2_a = mppt2_a, - lifetime_wh = lifetime_wh, - temp_c = cabinet_c, - rated_w = rated_w, - }) + -- Emit PV (DC power magnitude → negative for generation, per site + -- convention). DC power is PV's defining value: without it there is no + -- PV reading. Each other field is left out when it did not answer. + if pv_dc_w ~= nil then + host.emit("pv", { + w = -pv_dc_w, + mppt1_v = mppt1_v, + mppt1_a = mppt1_a, + mppt2_v = mppt2_v, + mppt2_a = mppt2_a, + lifetime_wh = lifetime_wh, + temp_c = cabinet_c, + rated_w = rated_w, + }) + end -- Diagnostics: long-format TS DB - host.emit_metric("pv_mppt1_v", mppt1_v) - host.emit_metric("pv_mppt1_a", mppt1_a) - host.emit_metric("pv_mppt2_v", mppt2_v) - host.emit_metric("pv_mppt2_a", mppt2_a) + if mppt1_v ~= nil then host.emit_metric("pv_mppt1_v", mppt1_v) end + if mppt1_a ~= nil then host.emit_metric("pv_mppt1_a", mppt1_a) end + if mppt2_v ~= nil then host.emit_metric("pv_mppt2_v", mppt2_v) end + if mppt2_a ~= nil then host.emit_metric("pv_mppt2_a", mppt2_a) end if cabinet_c ~= nil then host.emit_metric("inverter_temp_c", cabinet_c) end - host.emit_metric("grid_hz", hz) + if hz ~= nil then host.emit_metric("grid_hz", hz) end -- ----------------------------------------------------------- Battery -- - -- Fronius's GEN24 Modbus maps carry no battery temperature and no live - -- charge or discharge limit. Model 124 has no temperature point, and the - -- per-module Tmp in model 160 is "not supported". WChaMax is "Setpoint - -- for maximum charge", which the GEN24 manual defines as - -- max(MaxChaRte, MaxDisChaRte), the nameplate rates of model 120; it does - -- not move with the BMS, so it is not sent as available_charge_W. Nor is - -- there a grid import/export headroom point (model 122 WAval is "not - -- supported"). + -- Only with storage, which model 124 following model 160 proves. -- - -- NOTE, not changed here: the fixed model-124 addresses below assume a - -- two-module model 160. Fronius's own GEN24 storage maps (register map - -- bundle 1.2.7-2) add two storage modules to model 160 and put WChaMax - -- at register 40356 (float) or 40346 (int+SF), and the manual says to - -- find each model by walking the chain rather than by fixed address. - -- InBatV is "not supported" there, and OutWRte/InWRte are setpoints, not - -- measured rates. - - -- Max charge power: 40315, U16 raw × 10^max_charge_sf - local max_charge_w = 0 - local maxchg_regs = probe_read(40315, 1, "holding") - if maxchg_regs then - max_charge_w = apply_sf(maxchg_regs[1], max_charge_sf) - end - - -- Battery SoC: 40321, U16 raw (percent), convert to 0..1 fraction - local bat_soc = 0 - local bsoc_regs = probe_read(40321, 1, "holding") - if bsoc_regs then - bat_soc = apply_sf(bsoc_regs[1], soc_sf) / 100 - end - - -- Battery voltage: 40323, U16 raw × 10^bat_v_sf - local bat_v = 0 - local batv_regs = probe_read(40323, 1, "holding") - if batv_regs then - bat_v = apply_sf(batv_regs[1], bat_v_sf) - end - - -- Discharge rate % (I16): 40325 - local discharge_rate = 0 - local dis_regs = probe_read(40325, 1, "holding") - if dis_regs then - discharge_rate = apply_sf(host.decode_i16(dis_regs[1]), charge_rate_sf) - end + -- Power and voltage come from the two battery blocks of model 160 (see + -- above). Fronius sets the charge block to 0 + -- while the battery discharges and the discharge block to 0 while it + -- charges, so battery W = charge DCW - discharge DCW, positive charging + -- (site convention; evcc's fronius-gen24 template reads it the same + -- way). Both blocks carry the battery port's voltage since firmware + -- 1.31; up to 1.30 only the active one did, so the driver takes the + -- larger, and leaves the voltage out when both are 0. + -- + -- SoC is model 124's ChaState (offset 8) x 10^ChaState_SF (offset 22), + -- in percent: "Estimated_Capacity_Remaining [Wh] / + -- Estimated_Capacity_Maximum [Wh]" (GEN24 manual). + -- + -- Earlier versions took battery power from OutWRte / InWRte times + -- WChaMax. Those are the owner's charge and discharge rate setpoints + -- (WChaMax is max(MaxChaRte, MaxDisChaRte), a rating), not a measurement. + -- + -- Fronius's maps carry no battery temperature and no live charge or + -- discharge limit: model 124 has no temperature point, the battery + -- blocks' Tmp is "not supported", InBatV is "not supported", and model + -- 122's WAval (grid headroom) is "not supported". So none is sent. + + local bat_w, bat_v, bat_soc = nil, nil, nil + if storage_addr ~= nil then + if cha ~= nil then + local cha_w = sunspec_u16(mppt[module_base(cha) + 11], dcw_sf) + local dis_w = sunspec_u16(mppt[module_base(dis) + 11], dcw_sf) + if cha_w ~= nil and dis_w ~= nil then bat_w = cha_w - dis_w end + local cha_v = sunspec_u16(mppt[module_base(cha) + 10], dcv_sf) + local dis_v = sunspec_u16(mppt[module_base(dis) + 10], dcv_sf) + local v = math.max(cha_v or 0, dis_v or 0) + if v > 0 then bat_v = v end + end - -- Charge rate % (I16): 40326 - local charge_rate = 0 - local chg_regs = probe_read(40326, 1, "holding") - if chg_regs then - charge_rate = apply_sf(host.decode_i16(chg_regs[1]), charge_rate_sf) + local st = probe_read(storage_addr, 23, "holding") + if st and st[1] == 124 and st[23] ~= nil then + local pct = sunspec_u16(st[9], sunspec_sf(st[23])) + if pct ~= nil and pct >= 0 and pct <= 100 then bat_soc = pct / 100 end + end end - -- Site convention: positive W = charging, negative W = discharging. - -- Fronius reports direction as two separate percent rates + max power. - local bat_w = 0 - if discharge_rate > 0 then - bat_w = -(discharge_rate / 100) * max_charge_w - elseif charge_rate > 0 then - bat_w = (charge_rate / 100) * max_charge_w + if bat_w ~= nil or bat_v ~= nil or bat_soc ~= nil then + host.emit("battery", { + w = bat_w, + v = bat_v, + soc = bat_soc, + }) end - - host.emit("battery", { - w = bat_w, - v = bat_v, - soc = bat_soc, - }) - host.emit_metric("battery_dc_v", bat_v) + if bat_v ~= nil then host.emit_metric("battery_dc_v", bat_v) end -- NOTE: This driver does NOT emit meter telemetry. A Fronius inverter is -- NOT a grid meter — its AC output represents inverter production, not the @@ -392,4 +517,5 @@ end function driver_cleanup() sn_read = false + forget_models() end diff --git a/drivers/tests/invented-number-baseline.json b/drivers/tests/invented-number-baseline.json index 1aa5f20..935e481 100644 --- a/drivers/tests/invented-number-baseline.json +++ b/drivers/tests/invented-number-baseline.json @@ -23,7 +23,6 @@ "ctek_hybrid": 9, "ctek_v2": 9, "deye": 26, - "fronius": 10, "hello": 3, "janitza": 13, "kostal": 21, diff --git a/drivers/tests/test_fronius_storage_map.py b/drivers/tests/test_fronius_storage_map.py new file mode 100644 index 0000000..983dbad --- /dev/null +++ b/drivers/tests/test_fronius_storage_map.py @@ -0,0 +1,402 @@ +"""Fronius reads the battery where Fronius's GEN24 and Verto storage maps put it. + +Source: Fronius's register map bundle 1.2.7-2 (www.fronius.com/QR-link/0024, +linked from the GEN24 Modbus manual 42,0410,2649), the float maps with +storage. Fronius numbers registers from 1, so the wire address is one lower. + +* Model 160 (MPPT) starts at register 40264, wire 40263. Its length is + 8 + 20 x N. With storage, N counts the trackers plus two inputs for the + battery, "StCha" (charge) and "StDisCha" (discharge), the last two blocks. + A GEN24 has N = 4 (L = 88), a Verto with three trackers N = 5 (L = 108). +* Model 124 (storage) follows model 160 directly, and only with storage. + ChaState is at offset 8 and ChaState_SF at offset 22. +* Battery power is the charge input's DCW minus the discharge input's DCW + (Fronius sets the idle one to 0; evcc's fronius-gen24 template reads it + the same way). Battery voltage is the inputs' DCV: since firmware 1.31 + both carry it, before that only the active one did. +* With storage, PV power is the sum of the MPPT blocks before the battery + blocks, as evcc reads it: Fronius does not say whether model 113's DC + power includes the battery input. Without storage it is model 113's DC + power, as before. +* While no storage model is known, the driver looks again every five + minutes, and at once when model 160's length changes. + +Earlier releases read model 124 at fixed addresses that assume a two-input +model 160, so on a GEN24 with storage they landed in model 160's battery +blocks, and they took battery power from the OutWRte / InWRte setpoints. +They also sent a battery at 0 W, 0 V and 0 % on an inverter with none, and +their float decoder flipped the sign of every float on 32-bit Lua, which the +harness uses. +""" + +import struct +import subprocess +from pathlib import Path + +import pytest + +ROOT = Path(__file__).resolve().parents[2] +LUA = ROOT / "lua55" +HARNESS = ROOT / "drivers" / "tests" / "lua_harness" +DRIVER = ROOT / "drivers" / "lua" / "fronius.lua" + +pytestmark = pytest.mark.skipif( + not LUA.exists(), reason="run make check to build ./lua55") + +MPPT = 40263 # wire address of model 160's ID (register 40264) +NAN = (0x7FC0, 0x0000) + + +def u16(value: int) -> int: + return value & 0xFFFF + + +def text(s: str) -> list[int]: + raw = s.encode().ljust(16, b"\0") + return [raw[i] * 256 + raw[i + 1] for i in range(0, 16, 2)] + + +def site(trackers: int = 2, storage: bool = True, *, dca_sf=-2, dcv_sf=-1, + dcw_sf=0, cha=(0, 0, 0), dis=(0, 0, 0), soc_raw=5000, soc_sf=-2, + mppt1=(850, 3512), mppt2=(420, 3300), tracker_w=None, + names=None) -> dict[int, int]: + """Registers of a Fronius float map, keyed by wire address. + + cha / dis are (DCA, DCV, DCW) raw values for the storage inputs; + tracker_w the raw DCW of each MPPT tracker (0 when not given). + """ + n = trackers + (2 if storage else 0) + length = 8 + 20 * n + regs: dict[int, int] = { + MPPT: 160, MPPT + 1: length, + MPPT + 2: u16(dca_sf), MPPT + 3: u16(dcv_sf), MPPT + 4: u16(dcw_sf), + MPPT + 5: 0, MPPT + 8: n, + } + if names is None: + names = [f"MPPT {k}" for k in range(1, trackers + 1)] + if storage: + names += [f"StCha {trackers + 1}", f"StDisCha {trackers + 2}"] + values = [mppt1, mppt2] + [(0, 0)] * (trackers - 2) + tracker_w = list(tracker_w or [0] * trackers) + for k in range(1, n + 1): + base = MPPT + 10 + 20 * (k - 1) + regs[base] = k + for i, word in enumerate(text(names[k - 1])): + regs[base + 1 + i] = word + if k <= trackers: + dca, dcv = values[k - 1] + regs[base + 9], regs[base + 10] = dca, dcv + regs[base + 11] = tracker_w[k - 1] + else: + regs[base + 9], regs[base + 10], regs[base + 11] = ( + cha if k == trackers + 1 else dis) + nxt = MPPT + 2 + length + if storage: + regs[nxt], regs[nxt + 1] = 124, 24 + regs[nxt + 8] = soc_raw + regs[nxt + 22] = u16(soc_sf) + regs[nxt + 26] = 0xFFFF # end block + else: + regs[nxt], regs[nxt + 1] = 0xFFFF, 0 + return regs + + +def _poll(registers: dict, fail: tuple = (), polls: int = 1) -> dict[str, str]: + return _run([(registers, 0, polls)], fail) + + +def _run(phases: list, fail: tuple = ()) -> dict[str, str]: + """Each phase: (registers, ms to advance the clock first, polls).""" + failing = "\n".join( + f'host._modbus_read_fail_addresses[{addr}] = "Illegal Data Address"' + for addr in fail) + steps = [] + for registers, advance_ms, polls in phases: + setup = "\n".join( + f"host._modbus_registers.holding[{addr}] = {val}" + for addr, val in registers.items()) + steps.append(f''' +host._modbus_registers.holding = {{}} +{setup} +host._millis_counter = host._millis_counter + {advance_ms} +for _ = 1, {polls} do + host._emitted = {{}} + host._metrics = {{}} + local ok, err = pcall(driver_poll) + if not ok then print("POLL_ERROR " .. tostring(err)) os.exit(1) end +end +''') + body = "\n".join(steps) + script = f''' +package.path = "{HARNESS}/?.lua;" .. package.path +require("host_mock") +host.reset() +{failing} +dofile("{DRIVER}") +driver_init({{}}) +{body} +for _, der in ipairs({{"battery", "pv", "meter"}}) do + local list = host._emitted[der] + if list and #list > 0 then + print(der .. " emitted") + for k, v in pairs(list[#list]) do print(der .. "." .. k .. " " .. tostring(v)) end + end +end +for name, m in pairs(host._metrics) do print("metric." .. name .. " " .. tostring(m.value)) end +local reads = {{}} +for _, c in ipairs(host._calls) do + if c.func == "modbus_read" then reads[#reads + 1] = c.args[1] .. ":" .. c.args[2] end +end +print("reads " .. table.concat(reads, ",")) +''' + result = subprocess.run([str(LUA), "-e", script], + capture_output=True, text=True, cwd=ROOT) + assert result.returncode == 0, result.stdout + result.stderr + return dict(line.split(" ", 1) + for line in result.stdout.strip().splitlines() if " " in line) + + +def test_gen24_charging(): + # DCW_SF 0: 1234 W into the battery. DCV_SF -1: 52.3 V. ChaState 65.43 %. + out = _poll(site(cha=(2360, 523, 1234), dis=(0, 523, 0), soc_raw=6543)) + assert float(out["battery.w"]) == pytest.approx(1234) + assert float(out["battery.v"]) == pytest.approx(52.3) + assert float(out["battery.soc"]) == pytest.approx(0.6543) + assert float(out["metric.battery_dc_v"]) == pytest.approx(52.3) + + +def test_gen24_discharging_is_negative(): + out = _poll(site(dcw_sf=-1, cha=(0, 518, 0), dis=(4800, 518, 25000))) + assert float(out["battery.w"]) == pytest.approx(-2500) + assert float(out["battery.v"]) == pytest.approx(51.8) + + +def test_gen24_old_firmware_voltage_on_the_active_input_only(): + # Up to firmware 1.30 the idle input's DCV is 0 as well. + out = _poll(site(cha=(0, 0, 0), dis=(1000, 510, 500))) + assert float(out["battery.v"]) == pytest.approx(51.0) + assert float(out["battery.w"]) == pytest.approx(-500) + + +def test_gen24_idle_old_firmware_leaves_voltage_out(): + # Both inputs at 0 V means neither is active, not a 0 V battery. + out = _poll(site(cha=(0, 0, 0), dis=(0, 0, 0))) + assert "battery.v" not in out + assert "metric.battery_dc_v" not in out + assert float(out["battery.w"]) == 0 + assert float(out["battery.soc"]) == pytest.approx(0.5) + + +def test_verto_three_trackers_and_storage(): + # Verto: N = 5, model 124 at register 40374 (wire 40373). + regs = site(trackers=3, cha=(0, 0, 0), dis=(0, 0, 0), soc_raw=8000) + regs.update({MPPT + 10 + 20 * 3 + 9: 1500, MPPT + 10 + 20 * 3 + 10: 530, + MPPT + 10 + 20 * 3 + 11: 800}) + assert regs[40373] == 124 + out = _poll(regs) + assert float(out["battery.w"]) == pytest.approx(800) + assert float(out["battery.v"]) == pytest.approx(53.0) + assert float(out["battery.soc"]) == pytest.approx(0.8) + + +def test_mppt_values_from_the_model_160_block(): + out = _poll(site(mppt1=(850, 3512), mppt2=(420, 3300))) + assert float(out["pv.mppt1_a"]) == pytest.approx(8.5) + assert float(out["pv.mppt1_v"]) == pytest.approx(351.2) + assert float(out["pv.mppt2_a"]) == pytest.approx(4.2) + assert float(out["pv.mppt2_v"]) == pytest.approx(330.0) + + +def test_no_storage_sends_no_battery(): + out = _poll(site(storage=False), polls=3) + assert "battery" not in out + assert "metric.battery_dc_v" not in out + assert float(out["pv.mppt1_v"]) == pytest.approx(351.2) + + +def test_no_storage_reads_nothing_past_the_end_block(): + # The register after model 160 is the end block there (wire 40313), + # which answers, so the driver learns there is no battery without + # reading past the end of the map, where a real inverter answers with + # an exception. + out = _poll(site(storage=False), polls=3) + assert "battery" not in out + for read in out["reads"].split(","): + addr, count = (int(x) for x in read.split(":")) + assert addr + count <= 40315, f"read {count} registers at {addr}" + + +def test_model_124_does_not_answer(): + out = _poll(site(cha=(0, 520, 900)), fail=(40353,), polls=4) + assert "battery" not in out + + +def test_soc_not_implemented_leaves_soc_out(): + for regs in (site(cha=(0, 520, 900), soc_raw=0xFFFF), + site(cha=(0, 520, 900), soc_sf=-32768)): + out = _poll(regs) + assert "battery.soc" not in out + assert float(out["battery.w"]) == pytest.approx(900) + + +def test_soc_out_of_range_is_dropped(): + out = _poll(site(cha=(0, 520, 900), soc_raw=10001)) + assert "battery.soc" not in out + + +def test_storage_inputs_not_named_as_documented(): + names = ["MPPT 1", "MPPT 2", "MPPT 3", "MPPT 4"] + out = _poll(site(cha=(0, 520, 900), names=names)) + assert "battery.w" not in out + assert "battery.v" not in out + assert float(out["battery.soc"]) == pytest.approx(0.5) + + +def test_model_160_not_where_the_float_map_puts_it(): + # The int+SF maps start model 160 at register 40254; at 40264 there is + # something else. The driver reads no DC input or battery values then. + regs = site() + regs[MPPT] = 0 + out = _poll(regs) + assert "battery" not in out + assert not any(k.startswith("pv.mppt") for k in out) + + +def test_model_160_does_not_answer(): + out = _poll(site(), fail=(MPPT,), polls=4) + assert "battery" not in out + assert not any(k.startswith("pv.mppt") for k in out) + + +def test_old_addresses_are_not_read(): + # Main read WChaMax at wire 40315, ChaState at 40321, InBatV at 40323 and + # OutWRte / InWRte at 40325 / 40326 with scale factors at 40331-40338. + regs = site(cha=(0, 520, 900)) + out = _poll(regs, fail=(40315, 40321, 40323, 40325, 40326, + 40331, 40335, 40337, 40338)) + assert float(out["battery.w"]) == pytest.approx(900) + assert float(out["battery.soc"]) == pytest.approx(0.5) + + +def test_float_values_keep_their_sign(): + # 6000.0 W DC, 50.0 Hz, 12345678 Wh. Main's decoder joined the words into + # one 32-bit number and compared it with 0x80000000, which is negative on + # 32-bit Lua, so every float came out negative here. + regs = site(storage=False) + regs.update({40107: 0x45BB, 40108: 0x8000, # DCW 6000.0 + 40093: 0x4248, 40094: 0x0000, # Hz 50.0 + 40101: 0x4B3C, 40102: 0x614E}) # WH 12345678.0 + out = _poll(regs) + assert float(out["pv.w"]) == pytest.approx(-6000) + assert float(out["metric.grid_hz"]) == pytest.approx(50.0) + assert float(out["pv.lifetime_wh"]) == pytest.approx(12345678) + + +def test_float_nan_is_left_out_not_sent_as_zero(): + regs = site(storage=False) + regs.update({40107: NAN[0], 40108: NAN[1], + 40093: NAN[0], 40094: NAN[1], + 40101: NAN[0], 40102: NAN[1]}) + out = _poll(regs) + assert "pv" not in out # DC power is PV's defining value + assert "metric.grid_hz" not in out + + +def test_failed_pv_reads_are_left_out(): + out = _poll(site(), fail=(40101, 40093, 40134)) + assert "pv.lifetime_wh" not in out + assert "pv.rated_w" not in out + assert "metric.grid_hz" not in out + assert "pv.w" in out + + +def test_rated_power_with_its_scale_factor(): + regs = site() + regs.update({40134: 1000, 40135: 1}) # WRtg 1000 x 10^1 + out = _poll(regs) + assert float(out["pv.rated_w"]) == pytest.approx(10000) + + +DCW_113 = 40107 # model 113 DC power, float32 + + +def f32(value: float) -> tuple[int, int]: + word = struct.unpack(">I", struct.pack(">f", value))[0] + return word >> 16, word & 0xFFFF + + +def with_dcw(regs: dict, watts: float) -> dict: + regs[DCW_113], regs[DCW_113 + 1] = f32(watts) + return regs + + +def test_pv_with_storage_is_the_mppt_sum(): + # 2500 W of sun and a 3000 W discharge. Model 113's DC power may hold + # both; PV comes from the MPPT blocks before the battery blocks. + regs = with_dcw(site(tracker_w=(1500, 1000), dis=(5800, 518, 3000)), 5500.0) + out = _poll(regs) + assert float(out["pv.w"]) == pytest.approx(-2500) + assert float(out["battery.w"]) == pytest.approx(-3000) + + +def test_pv_with_storage_uses_the_scale_factor(): + regs = with_dcw(site(dcw_sf=-1, tracker_w=(15000, 10000)), 9999.0) + out = _poll(regs) + assert float(out["pv.w"]) == pytest.approx(-2500) + + +def test_verto_pv_sums_three_trackers(): + regs = with_dcw(site(trackers=3, tracker_w=(1000, 800, 600)), 9999.0) + out = _poll(regs) + assert float(out["pv.w"]) == pytest.approx(-2400) + + +def test_pv_without_storage_uses_model_113(): + regs = with_dcw(site(storage=False, tracker_w=(1500, 1000)), 4000.0) + out = _poll(regs) + assert float(out["pv.w"]) == pytest.approx(-4000) + + +def test_pv_tracker_not_implemented_leaves_pv_out(): + regs = with_dcw(site(tracker_w=(1500, 0xFFFF)), 4000.0) + out = _poll(regs) + assert "pv" not in out + + +def test_pv_left_out_with_storage_but_no_battery_blocks(): + names = ["MPPT 1", "MPPT 2", "MPPT 3", "MPPT 4"] + regs = with_dcw(site(tracker_w=(1500, 1000), names=names), 5500.0) + out = _poll(regs) + assert "pv" not in out + assert float(out["battery.soc"]) == pytest.approx(0.5) + + +def test_battery_fitted_later_is_found(): + # Without a battery model 160 has two blocks. Once one is fitted it has + # four and model 124 follows; the driver sees the new length and looks + # again. + before = with_dcw(site(storage=False), 4000.0) + after = with_dcw(site(tracker_w=(1500, 1000), cha=(1000, 520, 700)), 3200.0) + out = _run([(before, 0, 2), (after, 0, 2)]) + assert float(out["battery.w"]) == pytest.approx(700) + assert float(out["pv.w"]) == pytest.approx(-2500) + + +def _storage_model_appears(advance_ms: int) -> dict[str, str]: + # Model 160 already has its battery blocks, but model 124 is not there + # yet (the end block is), as before a battery is commissioned. + before = site(cha=(0, 520, 700)) + before[40353], before[40354] = 0xFFFF, 0 + after = site(cha=(0, 520, 700)) + return _run([(before, 0, 1), (after, advance_ms, 1)]) + + +def test_storage_model_is_looked_for_again_after_five_minutes(): + out = _storage_model_appears(5 * 60 * 1000) + assert float(out["battery.soc"]) == pytest.approx(0.5) + assert float(out["battery.w"]) == pytest.approx(700) + + +def test_storage_model_is_not_looked_for_on_every_poll(): + out = _storage_model_appears(60 * 1000) + assert "battery" not in out diff --git a/index.yaml b/index.yaml index 6672d7e..762fd25 100644 --- a/index.yaml +++ b/index.yaml @@ -252,14 +252,14 @@ drivers: size_bytes: 43733 sha256: "c7b3ce58731031340a76c21f15fb87cddb4b6a2cb6ac4320b39f748cf7eae9e9" - name: "fronius" - version: "2.2.0" + version: "2.3.0" tier: core protocol: modbus connectivity: local ders: [battery, meter, pv] control: false - size_bytes: 15342 - sha256: "c277eee7c0e829b6f385648109ae0fe1dd4dd0d7d0cd1015e4df07b12e84f58f" + size_bytes: 21704 + sha256: "63472dda17a0ed32c167dadb4ecf02f032bf4fb2e648df046a56de818124d16c" - name: "fronius_api" version: "1.0.2" tier: community diff --git a/manifests/fronius.yaml b/manifests/fronius.yaml index e2b4cf9..7d2b3b4 100644 --- a/manifests/fronius.yaml +++ b/manifests/fronius.yaml @@ -1,5 +1,5 @@ name: "fronius" -version: "2.2.0" +version: "2.3.0" tier: core author: "Sourceful Labs AB" protocol: modbus @@ -59,12 +59,12 @@ upstream_docs: kind: register_map url_stability: stable min_host_version: "2.0.0" -size_bytes: 15342 +size_bytes: 21704 dkb_id: "fronius_symo_gen24" -sha256: "c277eee7c0e829b6f385648109ae0fe1dd4dd0d7d0cd1015e4df07b12e84f58f" +sha256: "63472dda17a0ed32c167dadb4ecf02f032bf4fb2e648df046a56de818124d16c" signature: "" bytecode_sha256: "" bytecode_signature: "" bytecode_size: 0 -changelog: "" +changelog: "Read battery power, voltage and SoC where the GEN24 and Verto storage maps put them, take PV from the MPPT inputs when a battery is fitted, send no battery without storage, and decode floats correctly on 32-bit Lua." diff --git a/support-status.json b/support-status.json index b6a7eb8..4499dfb 100644 --- a/support-status.json +++ b/support-status.json @@ -569,7 +569,7 @@ }, { "catalog_source": true, - "catalog_version": "2.2.0", + "catalog_version": "2.3.0", "driver_id": "fronius", "targets": { "blixt-l1": {