diff --git a/CHANGELOG.md b/CHANGELOG.md index 4a1092b..5766b57 100644 --- a/CHANGELOG.md +++ b/CHANGELOG.md @@ -2,6 +2,29 @@ ## [Unreleased] +### growatt 2.2.2 + +A failed read no longer becomes 0 (docs/WRITING-A-DRIVER.md, "Never +fabricate"). Up to 2.2.1 every PV, battery and meter value started at 0, so a +read that did not answer sent 0 W, 0 V or 0 % SoC. A 0 W meter looks like a +site in balance, a 0 % SoC like an empty pack. + +- Each field comes only from a read that answered with every register asked + for; metrics likewise. +- PV goes out only when its power (1-2) answers, and the meter only when its + power (1015-1016) answers. So a failed power read also drops that + stream's energy counter and its MPPT or phase values for that poll; the + phase values still reach history as metrics. +- The battery follows "A hybrid inverter may have no battery": each field + only from a read that answered, and the stream when what answered shows a + battery. Its power needs both 1009 and 1011, since either alone is not the + net. + +This is the never-fabricate half of srcfl/device-drivers#263. Which +registers the meter should read is srcfl/device-drivers#271 and is not +changed here. growatt leaves `drivers/tests/invented-number-baseline.json`. +Not yet checked on hardware. + ### victron 2.2.1, ferroamp_modbus 2.2.1 A failed read no longer sends 0 on the meter and PV streams diff --git a/SUPPORT_STATUS.md b/SUPPORT_STATUS.md index dc99dfc..66cbb06 100644 --- a/SUPPORT_STATUS.md +++ b/SUPPORT_STATUS.md @@ -70,8 +70,8 @@ Catalog source is not proof that a target can install or run a driver. | goe_http | 1.1.0 | blixt-l1 | not_assessed | — | not_recorded | not_assessed | | goodwe | 2.2.0 | ftw-core | not_assessed | — | not_recorded | not_assessed | | goodwe | 2.2.0 | blixt-l1 | not_assessed | — | not_recorded | not_assessed | -| growatt | 2.2.1 | ftw-core | not_assessed | — | not_recorded | not_assessed | -| growatt | 2.2.1 | blixt-l1 | not_assessed | — | not_recorded | not_assessed | +| growatt | 2.2.2 | ftw-core | not_assessed | — | not_recorded | not_assessed | +| growatt | 2.2.2 | blixt-l1 | not_assessed | — | not_recorded | not_assessed | | hardybarth | 1.1.1 | ftw-core | not_assessed | — | not_recorded | not_assessed | | hardybarth | 1.1.1 | blixt-l1 | not_assessed | — | not_recorded | not_assessed | | heishamon | 0.8.1 | ftw-core | not_assessed | — | not_recorded | not_assessed | diff --git a/devices.yaml b/devices.yaml index 8adce80..36fe113 100644 --- a/devices.yaml +++ b/devices.yaml @@ -522,7 +522,7 @@ manufacturers: protocols: - protocol: modbus driver: "growatt" - version: "2.2.1" + version: "2.2.2" ders: [pv, battery, meter] control: false firmware_versions: "" @@ -533,7 +533,7 @@ manufacturers: protocols: - protocol: modbus driver: "growatt" - version: "2.2.1" + version: "2.2.2" ders: [pv, battery, meter] control: false firmware_versions: "" @@ -544,7 +544,7 @@ manufacturers: protocols: - protocol: modbus driver: "growatt" - version: "2.2.1" + version: "2.2.2" ders: [pv, battery, meter] control: false firmware_versions: "" @@ -555,7 +555,7 @@ manufacturers: protocols: - protocol: modbus driver: "growatt" - version: "2.2.1" + version: "2.2.2" ders: [pv, battery, meter] control: false firmware_versions: "" @@ -566,7 +566,7 @@ manufacturers: protocols: - protocol: modbus driver: "growatt" - version: "2.2.1" + version: "2.2.2" ders: [pv, battery, meter] control: false firmware_versions: "" @@ -577,7 +577,7 @@ manufacturers: protocols: - protocol: modbus driver: "growatt" - version: "2.2.1" + version: "2.2.2" ders: [pv, battery, meter] control: false firmware_versions: "" diff --git a/drivers/lua/growatt.lua b/drivers/lua/growatt.lua index 6dc7b4f..fe2dca7 100644 --- a/drivers/lua/growatt.lua +++ b/drivers/lua/growatt.lua @@ -21,7 +21,7 @@ DRIVER = { id = "growatt", name = "Growatt hybrid inverter", manufacturer = "Growatt", - version = "2.2.1", + version = "2.2.2", protocols = { "modbus" }, capabilities = { "meter", "pv", "battery" }, read_only = true, @@ -95,6 +95,14 @@ local function plausible_temp(c) return c end +-- A read that answered with every register asked for, or nil. A shorter +-- reply would leave a missing word for the decoders to misread. +local function read_input(addr, count) + local regs = probe_read(addr, count, "input") + if regs and regs[count] ~= nil then return regs end + return nil +end + ---------------------------------------------------------------------------- -- Initialization ---------------------------------------------------------------------------- @@ -109,59 +117,53 @@ end ---------------------------------------------------------------------------- function driver_poll() + -- A read that failed is left out, never sent as 0 (docs/WRITING-A-DRIVER.md, + -- "Never fabricate"): 0 W looks like a site in balance, 0 % SoC like an + -- empty pack. Each field comes only from a read that answered with every + -- register asked for, and PV and meter go out only with their power. + -- ---- PV ---- + local pv = {} + -- PV total power: 1-2, U32 BE × 0.1 W - local pvw_regs = probe_read(1, 2, "input") - local pv_w = 0 + local pvw_regs = read_input(1, 2) if pvw_regs then - pv_w = host.decode_u32_be(pvw_regs[1], pvw_regs[2]) * 0.1 + pv.w = -host.decode_u32_be(pvw_regs[1], pvw_regs[2]) * 0.1 -- generation is negative end -- PV1 V/A: 3-4, U16 × 0.1 V, U16 × 0.1 A - local m1_regs = probe_read(3, 2, "input") - local mppt1_v, mppt1_a = 0, 0 + local m1_regs = read_input(3, 2) if m1_regs then - mppt1_v = m1_regs[1] * 0.1 - mppt1_a = m1_regs[2] * 0.1 + pv.mppt1_v = m1_regs[1] * 0.1 + pv.mppt1_a = m1_regs[2] * 0.1 end -- PV2 V/A: 7-8, U16 × 0.1 V, U16 × 0.1 A - local m2_regs = probe_read(7, 2, "input") - local mppt2_v, mppt2_a = 0, 0 + local m2_regs = read_input(7, 2) if m2_regs then - mppt2_v = m2_regs[1] * 0.1 - mppt2_a = m2_regs[2] * 0.1 + pv.mppt2_v = m2_regs[1] * 0.1 + pv.mppt2_a = m2_regs[2] * 0.1 end -- Grid frequency: 37, U16 × 0.01 Hz - local hz_regs = probe_read(37, 1, "input") - local hz = 0 + local hz_regs = read_input(37, 1) + local hz if hz_regs then hz = hz_regs[1] * 0.01 + host.emit_metric("grid_hz", hz) end -- Total PV lifetime energy: 91-92, U32 BE × 0.1 kWh → × 1000 for Wh - local pvgen_regs = probe_read(91, 2, "input") - local pv_gen_wh = 0 + local pvgen_regs = read_input(91, 2) if pvgen_regs then - pv_gen_wh = host.decode_u32_be(pvgen_regs[1], pvgen_regs[2]) * 0.1 * 1000 + pv.lifetime_wh = host.decode_u32_be(pvgen_regs[1], pvgen_regs[2]) * 0.1 * 1000 end - -- Emit PV telemetry (site convention: generation is negative). - host.emit("pv", { - w = -pv_w, - mppt1_v = mppt1_v, - mppt1_a = mppt1_a, - mppt2_v = mppt2_v, - mppt2_a = mppt2_a, - lifetime_wh = pv_gen_wh, - }) - host.emit_metric("pv_mppt1_v", mppt1_v) - host.emit_metric("pv_mppt1_a", mppt1_a) - host.emit_metric("pv_mppt2_v", mppt2_v) - host.emit_metric("pv_mppt2_a", mppt2_a) - host.emit_metric("grid_hz", hz) + if pv.w ~= nil then host.emit("pv", pv) end + for _, name in ipairs({ "mppt1_v", "mppt1_a", "mppt2_v", "mppt2_a" }) do + if pv[name] ~= nil then host.emit_metric("pv_" .. name, pv[name]) end + end -- ---- Battery ---- @@ -171,37 +173,30 @@ function driver_poll() -- Growatt-Local-Modbus maps them the same way. Up to 2.2.0 this driver -- read them the other way round and showed charging as discharging -- (srcfl/device-drivers#263). - local bdisw_regs = probe_read(1009, 2, "input") - local bat_discharge_w = 0 + local bdisw_regs = read_input(1009, 2) + local bat_discharge_w if bdisw_regs then bat_discharge_w = host.decode_u32_be(bdisw_regs[1], bdisw_regs[2]) * 0.1 end - local bchgw_regs = probe_read(1011, 2, "input") - local bat_charge_w = 0 + local bchgw_regs = read_input(1011, 2) + local bat_charge_w if bchgw_regs then bat_charge_w = host.decode_u32_be(bchgw_regs[1], bchgw_regs[2]) * 0.1 end - -- Net battery power: positive = charging, negative = discharging (site convention). - local bat_w = bat_charge_w - bat_discharge_w - -- Battery voltage: 1013, U16 × 0.1 V - local bv_regs = probe_read(1013, 1, "input") - local bat_v = 0 - if bv_regs then - bat_v = bv_regs[1] * 0.1 - end + local bv_regs = read_input(1013, 1) + local bat_v + if bv_regs then bat_v = bv_regs[1] * 0.1 end -- Battery SoC: 1014, U16, percent → 0-1 fraction - local bsoc_regs = probe_read(1014, 1, "input") - local bat_soc = 0 - if bsoc_regs then - bat_soc = bsoc_regs[1] / 100 - end + local bsoc_regs = read_input(1014, 1) + local bat_soc + if bsoc_regs then bat_soc = bsoc_regs[1] / 100 end -- Battery temperature: 1040, U16 × 0.1 °C - local btemp_regs = probe_read(1040, 1, "input") + local btemp_regs = read_input(1040, 1) local bat_temp if btemp_regs then bat_temp = plausible_temp(btemp_regs[1] * 0.1) @@ -213,22 +208,29 @@ function driver_poll() -- terminal voltage and/or SoC above 0 even at rest, so treat all-zero -- battery readings as "no battery present" and skip the emit. -- see srcfl/ftw#1669 - local has_battery = bat_v > 0 or bat_soc > 0 or bat_charge_w > 0 or bat_discharge_w > 0 + -- Only a read that answered can show a battery (docs/WRITING-A-DRIVER.md, + -- "A hybrid inverter may have no battery"). + local function above_zero(v) return v ~= nil and v > 0 end + local has_battery = above_zero(bat_v) or above_zero(bat_soc) + or above_zero(bat_charge_w) or above_zero(bat_discharge_w) if has_battery then - host.emit("battery", { - w = bat_w, - v = bat_v, - soc = bat_soc, - temp_c = bat_temp, - }) - host.emit_metric("battery_dc_v", bat_v) + local battery = { v = bat_v, soc = bat_soc, temp_c = bat_temp } + -- Net power needs both registers: either alone is not the net. + -- Positive = charging, negative = discharging (site convention). + if bat_charge_w ~= nil and bat_discharge_w ~= nil then + battery.w = bat_charge_w - bat_discharge_w + end + host.emit("battery", battery) + if bat_v ~= nil then + host.emit_metric("battery_dc_v", bat_v) + end if bat_temp ~= nil then host.emit_metric("battery_temp_c", bat_temp) end -- Max / min cell temperature from the BMS: 1114-1115, U16 × 0.1 °C. - local cell_regs = probe_read(1114, 2, "input") - if cell_regs and cell_regs[2] ~= nil then + local cell_regs = read_input(1114, 2) + if cell_regs then local cell_max = plausible_temp(cell_regs[1] * 0.1) local cell_min = plausible_temp(cell_regs[2] * 0.1) if cell_max ~= nil then @@ -241,7 +243,7 @@ function driver_poll() end -- Inverter temperature: 93, U16 × 0.1 °C - local itemp_regs = probe_read(93, 1, "input") + local itemp_regs = read_input(93, 1) if itemp_regs then local inv_temp = plausible_temp(itemp_regs[1] * 0.1) if inv_temp ~= nil then @@ -250,85 +252,46 @@ function driver_poll() end -- ---- Meter ---- + -- Which registers these should be is srcfl/device-drivers#271; this + -- release only stops a failed read from becoming 0. + + local meter = { hz = hz } -- Meter total power: 1015-1016, I32 BE × 0.1 W -- Growatt sign: positive = import (matches site convention). - local mw_regs = probe_read(1015, 2, "input") - local meter_w = 0 + local mw_regs = read_input(1015, 2) if mw_regs then - meter_w = host.decode_i32_be(mw_regs[1], mw_regs[2]) * 0.1 + meter.w = host.decode_i32_be(mw_regs[1], mw_regs[2]) * 0.1 end -- Per-phase voltages: L1=38, L2=42, L3=46, U16 × 0.1 V - local lv1_regs = probe_read(38, 1, "input") - local l1_v = 0 - if lv1_regs then - l1_v = lv1_regs[1] * 0.1 - end - - local lv2_regs = probe_read(42, 1, "input") - local l2_v = 0 - if lv2_regs then - l2_v = lv2_regs[1] * 0.1 - end - - local lv3_regs = probe_read(46, 1, "input") - local l3_v = 0 - if lv3_regs then - l3_v = lv3_regs[1] * 0.1 - end - -- Per-phase currents: L1=39, L2=43, L3=47, U16 × 0.1 A - local la1_regs = probe_read(39, 1, "input") - local l1_a = 0 - if la1_regs then - l1_a = la1_regs[1] * 0.1 - end - - local la2_regs = probe_read(43, 1, "input") - local l2_a = 0 - if la2_regs then - l2_a = la2_regs[1] * 0.1 - end - - local la3_regs = probe_read(47, 1, "input") - local l3_a = 0 - if la3_regs then - l3_a = la3_regs[1] * 0.1 + for phase, addr in ipairs({ 38, 42, 46 }) do + local v_regs = read_input(addr, 1) + if v_regs then meter["l" .. phase .. "_v"] = v_regs[1] * 0.1 end + local a_regs = read_input(addr + 1, 1) + if a_regs then meter["l" .. phase .. "_a"] = a_regs[1] * 0.1 end end -- Total import energy: 1021-1022, U32 BE × 0.1 kWh → × 1000 for Wh - local imp_regs = probe_read(1021, 2, "input") - local import_wh = 0 + local imp_regs = read_input(1021, 2) if imp_regs then - import_wh = host.decode_u32_be(imp_regs[1], imp_regs[2]) * 0.1 * 1000 + meter.import_wh = host.decode_u32_be(imp_regs[1], imp_regs[2]) * 0.1 * 1000 end -- Total export energy: 1029-1030, U32 BE × 0.1 kWh → × 1000 for Wh - local exp_regs = probe_read(1029, 2, "input") - local export_wh = 0 + local exp_regs = read_input(1029, 2) if exp_regs then - export_wh = host.decode_u32_be(exp_regs[1], exp_regs[2]) * 0.1 * 1000 + meter.export_wh = host.decode_u32_be(exp_regs[1], exp_regs[2]) * 0.1 * 1000 end - host.emit("meter", { - w = meter_w, - l1_v = l1_v, - l2_v = l2_v, - l3_v = l3_v, - l1_a = l1_a, - l2_a = l2_a, - l3_a = l3_a, - hz = hz, - import_wh = import_wh, - export_wh = export_wh, - }) - host.emit_metric("meter_l1_v", l1_v) - host.emit_metric("meter_l2_v", l2_v) - host.emit_metric("meter_l3_v", l3_v) - host.emit_metric("meter_l1_a", l1_a) - host.emit_metric("meter_l2_a", l2_a) - host.emit_metric("meter_l3_a", l3_a) + if meter.w ~= nil then host.emit("meter", meter) end + for phase = 1, 3 do + for _, unit in ipairs({ "v", "a" }) do + local name = "l" .. phase .. "_" .. unit + if meter[name] ~= nil then host.emit_metric("meter_" .. name, meter[name]) end + end + end return 5000 end diff --git a/drivers/tests/invented-number-baseline.json b/drivers/tests/invented-number-baseline.json index 1a12bb2..3bf2d05 100644 --- a/drivers/tests/invented-number-baseline.json +++ b/drivers/tests/invented-number-baseline.json @@ -25,7 +25,6 @@ "deye": 26, "fronius": 10, "goodwe": 23, - "growatt": 16, "hello": 3, "janitza": 13, "kostal": 21, diff --git a/drivers/tests/test_growatt_never_fabricate.py b/drivers/tests/test_growatt_never_fabricate.py new file mode 100644 index 0000000..0800be4 --- /dev/null +++ b/drivers/tests/test_growatt_never_fabricate.py @@ -0,0 +1,226 @@ +"""Growatt: a read that failed is left out, never sent as 0. + +docs/WRITING-A-DRIVER.md, "Never fabricate": a field that did not answer is +left out, and a stream whose defining reading did not answer is not emitted. +Up to 2.2.1 this driver started every PV, battery and meter value at 0, so a +failed read became 0 W, 0 V or 0 % SoC. A 0 W meter looks like a site in +balance; a 0 % SoC like an empty pack. + +The battery follows "A hybrid inverter may have no battery": each field +comes only from a read that answered, and the stream goes out when what +answered shows a battery. Its power needs both 1009 (discharge) and 1011 +(charge). + +This is the never-fabricate half of srcfl/device-drivers#263. Which +registers the meter should read is srcfl/device-drivers#271; the addresses +here are the driver's current ones. The values are synthetic, not a capture. +""" + +import subprocess +from pathlib import Path + +import pytest + +ROOT = Path(__file__).resolve().parents[2] +LUA = ROOT / "lua55" +HARNESS = ROOT / "drivers" / "tests" / "lua_harness" +DRIVER = ROOT / "drivers" / "lua" / "growatt.lua" + +pytestmark = pytest.mark.skipif( + not LUA.exists(), reason="run make check to build ./lua55") + +REGISTERS = { + 1: [0, 41000], # PV power 4100 W + 3: [3500, 62], # MPPT1 350.0 V, 6.2 A + 7: [3400, 55], # MPPT2 340.0 V, 5.5 A + 37: [5001], # 50.01 Hz + 38: [2310], 39: [52], # L1 231.0 V, 5.2 A + 42: [2290], 43: [41], # L2 229.0 V, 4.1 A + 46: [2300], 47: [33], # L3 230.0 V, 3.3 A + 91: [0, 123456], # PV lifetime 12345.6 kWh + 93: [387], # inverter 38.7 C + 1009: [0, 0], # Pdischarge1 0 W + 1011: [0, 15000], # Pcharge1 1500 W + 1013: [520], # 52.0 V + 1014: [64], # 64 % + 1015: [0, 4500], # meter 450 W import + 1021: [0, 51000], # import counter + 1029: [0, 22000], # export counter + 1040: [212], # battery 21.2 C + 1114: [230, 198], # cells 23.0 / 19.8 C +} + +STREAMS = { + "pv": ["w", "mppt1_v", "mppt1_a", "mppt2_v", "mppt2_a", "lifetime_wh"], + "battery": ["w", "v", "soc", "temp_c"], + "meter": ["w", "l1_v", "l2_v", "l3_v", "l1_a", "l2_a", "l3_a", "hz", + "import_wh", "export_wh"], +} +METRICS = ["pv_mppt1_v", "pv_mppt2_v", "pv_mppt2_a", "grid_hz", "battery_dc_v", + "meter_l1_v", "meter_l2_v", "meter_l2_a", "meter_l3_a"] + + +def _lua_list(values) -> str: + return "{" + ", ".join(str(v) for v in values) + "}" + + +def poll(fail: tuple[int, ...] = (), regs: dict | None = None, + short: dict[int, int] | None = None) -> dict[str, str]: + """Poll once. `fail` addresses raise; `short` maps an address to how + many registers its reply carries.""" + regs = REGISTERS if regs is None else regs + setup = "\n".join( + f"host._modbus_registers.input[{addr}] = {_lua_list(vals)}" + for addr, vals in regs.items()) + setup += "\n" + "\n".join( + f'host._modbus_read_fail_addresses[{addr}] = "Illegal Data Address"' + for addr in fail) + setup += "\n" + "\n".join( + f"host._modbus_read_short_counts[{addr}] = {count}" + for addr, count in (short or {}).items()) + body = "" + for stream, fields in STREAMS.items(): + body += "do\n" + ( + f'local s = host._emitted.{stream} and host._emitted.{stream}[1]\n' + f'print("{stream} " .. tostring(s ~= nil))\n') + for field in fields: + body += f'print("{stream}.{field} " .. tostring(s and s.{field}))\n' + body += "end\n" + for name in METRICS: + body += (f'do local m = host._metrics["{name}"] ' + f'print("metric.{name} " .. tostring(m and m.value)) end\n') + script = f''' +package.path = "{HARNESS}/?.lua;" .. package.path +require("host_mock") +host.reset() +{setup} +dofile("{DRIVER}") +driver_init({{}}) +local ok, err = pcall(driver_poll) +if not ok then print("POLL_ERROR " .. tostring(err)) os.exit(1) end +{body} +''' + result = subprocess.run([str(LUA), "-e", script], + capture_output=True, text=True, cwd=ROOT) + assert result.returncode == 0, result.stdout + result.stderr + return dict(line.split(" ", 1) + for line in result.stdout.strip().splitlines() if " " in line) + + +def num(out: dict[str, str], key: str) -> float: + assert out[key] != "nil", f"{key} left out" + return float(out[key]) + + +def test_growatt_all_answer(): + out = poll() + assert num(out, "pv.w") == pytest.approx(-4100) + assert num(out, "pv.mppt2_a") == pytest.approx(5.5) + assert num(out, "battery.w") == pytest.approx(1500) + assert num(out, "battery.soc") == pytest.approx(0.64) + assert num(out, "meter.w") == pytest.approx(450) + assert num(out, "meter.hz") == pytest.approx(50.01) + assert num(out, "metric.meter_l2_v") == pytest.approx(229) + + +def test_growatt_no_pv_reading_without_pv_power(): + out = poll(fail=(1,)) + assert out["pv"] == "false" + assert out["meter"] == "true" + + +def test_growatt_failed_mppt_read_is_left_out(): + out = poll(fail=(7,)) + assert num(out, "pv.w") == pytest.approx(-4100) + assert num(out, "pv.mppt1_v") == pytest.approx(350) + assert out["pv.mppt2_v"] == "nil" + assert out["pv.mppt2_a"] == "nil" + assert out["metric.pv_mppt2_v"] == "nil" + assert out["metric.pv_mppt2_a"] == "nil" + + +def test_growatt_failed_lifetime_read_is_left_out(): + out = poll(fail=(91,)) + assert num(out, "pv.w") == pytest.approx(-4100) + assert out["pv.lifetime_wh"] == "nil" + + +def test_growatt_no_meter_reading_without_meter_power(): + # 0 W from a failed read looks like a site in balance. + out = poll(fail=(1015,)) + assert out["meter"] == "false" + assert out["pv"] == "true" + + +def test_growatt_failed_phase_and_frequency_reads_are_left_out(): + out = poll(fail=(42, 43, 37)) + assert num(out, "meter.w") == pytest.approx(450) + assert num(out, "meter.l1_v") == pytest.approx(231) + assert out["meter.l2_v"] == "nil" + assert out["meter.l2_a"] == "nil" + assert out["meter.hz"] == "nil" + assert out["metric.meter_l2_v"] == "nil" + assert out["metric.meter_l2_a"] == "nil" + assert out["metric.grid_hz"] == "nil" + assert num(out, "metric.meter_l3_a") == pytest.approx(3.3) + + +def test_growatt_failed_energy_counters_are_left_out(): + out = poll(fail=(1021, 1029)) + assert out["meter.import_wh"] == "nil" + assert out["meter.export_wh"] == "nil" + + +def test_growatt_failed_soc_read_is_left_out(): + # 0 % SoC from a failed read looks like an empty pack. + out = poll(fail=(1014,)) + assert out["battery"] == "true" + assert out["battery.soc"] == "nil" + assert num(out, "battery.v") == pytest.approx(52.0) + + +def test_growatt_failed_voltage_read_is_left_out(): + out = poll(fail=(1013,)) + assert out["battery"] == "true" + assert out["battery.v"] == "nil" + assert out["metric.battery_dc_v"] == "nil" + assert num(out, "battery.soc") == pytest.approx(0.64) + + +def test_growatt_battery_power_needs_both_registers(): + # Charge alone is not the net power: discharge did not answer. + out = poll(fail=(1009,)) + assert out["battery"] == "true" + assert out["battery.w"] == "nil" + out = poll(fail=(1011,)) + assert out["battery.w"] == "nil" + + +def test_growatt_battery_without_power_reads(): + # Neither 1009 nor 1011 answered, but voltage and SoC did: the battery + # goes out without w ("A hybrid inverter may have no battery"). + out = poll(fail=(1009, 1011)) + assert out["battery"] == "true" + assert out["battery.w"] == "nil" + assert num(out, "battery.v") == pytest.approx(52.0) + assert num(out, "battery.soc") == pytest.approx(0.64) + + +def test_growatt_short_reply_is_left_out(): + # One word back for a two-word read: the missing word must not decode + # as part of a number. + out = poll(short={1: 1, 1015: 1, 91: 1, 1011: 1}) + assert out["pv"] == "false" + assert out["meter"] == "false" + assert out["battery"] == "true" + assert out["battery.w"] == "nil" + assert num(out, "battery.soc") == pytest.approx(0.64) + + +def test_growatt_nothing_answers_sends_nothing(): + out = poll(fail=tuple(REGISTERS)) + assert out["pv"] == "false" + assert out["battery"] == "false" + assert out["meter"] == "false" + for name in METRICS: + assert out[f"metric.{name}"] == "nil", name diff --git a/index.yaml b/index.yaml index 3f7c523..11369da 100644 --- a/index.yaml +++ b/index.yaml @@ -309,14 +309,14 @@ drivers: size_bytes: 14972 sha256: "2bd0ddc5df2754bf8e807aea05529d59809ef65282f4a55a5823e481339be363" - name: "growatt" - version: "2.2.1" + version: "2.2.2" tier: community protocol: modbus connectivity: local ders: [pv, battery, meter] control: false - size_bytes: 12137 - sha256: "ce2cf6f114d832adc3708c825cf7224589b3c04f098ba5ac694018b3a3dc839b" + size_bytes: 11978 + sha256: "6e9bee48e0d1e851922b3d9fc6b29dcd3649f5cf4da5f5a4050c05969a7c06e8" - name: "hardybarth" version: "1.1.1" tier: community diff --git a/manifests/growatt.yaml b/manifests/growatt.yaml index afe36e9..182152a 100644 --- a/manifests/growatt.yaml +++ b/manifests/growatt.yaml @@ -1,5 +1,5 @@ name: "growatt" -version: "2.2.1" +version: "2.2.2" tier: community author: "Sourceful Labs AB" protocol: modbus @@ -59,12 +59,12 @@ upstream_docs: kind: register_map url_stability: volatile min_host_version: "2.0.0" -size_bytes: 12137 +size_bytes: 11978 dkb_id: "" -sha256: "ce2cf6f114d832adc3708c825cf7224589b3c04f098ba5ac694018b3a3dc839b" +sha256: "6e9bee48e0d1e851922b3d9fc6b29dcd3649f5cf4da5f5a4050c05969a7c06e8" signature: "" bytecode_sha256: "" bytecode_signature: "" bytecode_size: 0 -changelog: "Read discharge power at 1009 and charge power at 1011, as Growatt's protocol says, so a charging battery is positive." +changelog: "Leave a failed read out instead of sending 0; send PV and meter only with their power." diff --git a/support-status.json b/support-status.json index 8148f56..4cb6a48 100644 --- a/support-status.json +++ b/support-status.json @@ -695,7 +695,7 @@ }, { "catalog_source": true, - "catalog_version": "2.2.1", + "catalog_version": "2.2.2", "driver_id": "growatt", "targets": { "blixt-l1": {