From 010aea50a6d4679c4a5f2934e2f0b097213b9b4f Mon Sep 17 00:00:00 2001 From: Fredrik Ahlgren Date: Tue, 17 Nov 2026 21:59:21 +0200 Subject: [PATCH] fix(mpc): plan an out-of-band battery from the band edge for every planner Core clamped a start below soc_min (or above soc_max) onto the band edge only when Core DP was the planner. Energyplan got the real start. On a v0.164.0-beta.1 site a Pixii settled at 0.097 under a 0.10 floor, with a car in the plan; Energyplan's fleet MILP published an idle battery for 28 h although cheap night power made charging pay. A replay of that request with the start on the floor charges 17.8 kWh at night, on both bundled workers (847936a and 7ea7d998). And when the worker failed in that state, Core kept the previous plan, since its DP could not model the out-of-band start. Replan now clamps for every planner and records the real reading in InitialSoCUnclamped, as it did for Core DP. The recovery-only branches go: shadows, baselines and the Core fallback run as for any start. A site Core DP cannot model, such as two storages, still keeps its previous plan when the worker fails. Refs #2043. Co-Authored-By: Claude Opus 5.5 Signed-off-by: Fredrik Ahlgren --- .changeset/plan-from-band-edge.md | 11 ++ go/internal/mpc/energyplan_fault_test.go | 13 +- go/internal/mpc/energyplan_test.go | 10 +- go/internal/mpc/import_hours_test.go | 26 ++-- go/internal/mpc/params_validation.go | 18 ++- go/internal/mpc/params_validation_test.go | 137 ++++++++++------------ go/internal/mpc/service.go | 30 ++--- 7 files changed, 114 insertions(+), 131 deletions(-) create mode 100644 .changeset/plan-from-band-edge.md diff --git a/.changeset/plan-from-band-edge.md b/.changeset/plan-from-band-edge.md new file mode 100644 index 000000000..ba0b9d32c --- /dev/null +++ b/.changeset/plan-from-band-edge.md @@ -0,0 +1,11 @@ +--- +"ftw": patch +--- + +A battery that sits below its lowest allowed charge, or above its highest, +gets a plan again. Core now gives Energyplan the nearest allowed charge, as it +already did for its own planner. With a car in the plan, Energyplan had kept +such a battery idle for a whole day, even when cheap night power made +charging pay. If Energyplan fails in that state, Core now plans from that +charge, where its own planner can model the site, instead of keeping an old +plan. diff --git a/go/internal/mpc/energyplan_fault_test.go b/go/internal/mpc/energyplan_fault_test.go index 7b341ec41..554e56f75 100644 --- a/go/internal/mpc/energyplan_fault_test.go +++ b/go/internal/mpc/energyplan_fault_test.go @@ -74,8 +74,8 @@ func TestNativeEnergyplanEVRecoveryFallbackFaults(t *testing.T) { var previousBytes []byte if scenario == "infeasible_keep_previous" { previous = svc.Replan(context.Background()) - if previous == nil || previous.Solver == nil || previous.Solver.Fallback || previous.InitialSoC != measuredSoC { - t.Fatalf("native baseline did not publish from measured low SoC: %+v", previous) + if previous == nil || previous.Solver == nil || previous.Solver.Fallback || previous.InitialSoC != svc.Defaults.SoCMin { + t.Fatalf("native baseline did not publish from the floor: %+v", previous) } svc.shadowWG.Wait() if err := ValidatePlan(svc.lastSlots, svc.lastParams, previous); err != nil { @@ -101,8 +101,9 @@ func TestNativeEnergyplanEVRecoveryFallbackFaults(t *testing.T) { if len(request.Storages) != 1 || len(request.FlexLoads) != 1 { t.Fatalf("fault did not exercise battery+EV: storages=%d flex=%d", len(request.Storages), len(request.FlexLoads)) } - if math.Abs(request.Storages[0].InitialEnergyWh-measuredSoC*svc.Defaults.CapacityWh) > 1e-9 { - t.Fatalf("worker request clamped measured initial energy: %+v", request.Storages[0]) + // A battery below its floor reaches the worker on the floor (#2043). + if math.Abs(request.Storages[0].InitialEnergyWh-request.Storages[0].MinEnergyWh) > 1e-9 { + t.Fatalf("worker request did not start on the floor: %+v", request.Storages[0]) } if scenario != "feasible" { if previous == nil { @@ -128,8 +129,8 @@ func TestNativeEnergyplanEVRecoveryFallbackFaults(t *testing.T) { if !strings.Contains(plan.Solver.FallbackReason, reason) { t.Fatalf("wrong fallback reason: %+v", plan.Solver) } - if plan.InitialSoC != measuredSoC || svc.lastParams.InitialSoC != measuredSoC || svc.lastParams.InitialSoC >= svc.lastParams.SoCMin { - t.Fatalf("fallback clamped recovery start: plan=%g params=%g floor=%g", plan.InitialSoC, svc.lastParams.InitialSoC, svc.lastParams.SoCMin) + if plan.InitialSoC != svc.lastParams.SoCMin || svc.lastParams.InitialSoCUnclamped != measuredSoC { + t.Fatalf("fallback start: plan=%g floor=%g real=%g", plan.InitialSoC, svc.lastParams.SoCMin, svc.lastParams.InitialSoCUnclamped) } if err := ValidatePlan(svc.lastSlots, svc.lastParams, plan); err != nil { t.Fatalf("published fallback failed physical replay: %v", err) diff --git a/go/internal/mpc/energyplan_test.go b/go/internal/mpc/energyplan_test.go index df5bfffa4..9651b57e8 100644 --- a/go/internal/mpc/energyplan_test.go +++ b/go/internal/mpc/energyplan_test.go @@ -169,7 +169,9 @@ func TestCoreDPShadowDoesNotAttachToNewerPlan(t *testing.T) { } } -func TestNativeEnergyplanRecoveryKeepsRealBatteryEnergy(t *testing.T) { +// A battery outside its band reaches Energyplan on the band edge, and the +// real reading is kept beside it (#2043). +func TestNativeEnergyplanPlansFromTheBandEdge(t *testing.T) { for _, initial := range []float64{0, .025, .975, 1} { t.Run(fmt.Sprint(initial), func(t *testing.T) { o := nativeWorker(t, 500*time.Millisecond) @@ -178,8 +180,10 @@ func TestNativeEnergyplanRecoveryKeepsRealBatteryEnergy(t *testing.T) { svc.Defaults.InitialSoC = initial svc.Optimizer = &EnergyplanOptimizer{ExternalOptimizer: o} plan := svc.Replan(context.Background()) - if plan == nil || plan.Solver.Fallback || plan.Solver.Backend != "value_curve_rust" || plan.InitialSoC != initial { - t.Fatalf("Energyplan must plan from real SoC without fallback: %+v", plan) + edge := math.Min(math.Max(initial, svc.Defaults.SoCMin), svc.Defaults.SoCMax) + if plan == nil || plan.Solver.Fallback || plan.Solver.Backend != "value_curve_rust" || plan.InitialSoC != edge || + svc.lastParams.InitialSoCUnclamped != initial { + t.Fatalf("Energyplan must plan from the band edge without fallback: %+v", plan) } if err := ValidatePlan(svc.lastSlots, svc.lastParams, plan); err != nil { t.Fatal(err) diff --git a/go/internal/mpc/import_hours_test.go b/go/internal/mpc/import_hours_test.go index bd6f00f13..e12fe52c5 100644 --- a/go/internal/mpc/import_hours_test.go +++ b/go/internal/mpc/import_hours_test.go @@ -429,10 +429,9 @@ func (ceilinglessOptimizer) Optimize(ctx context.Context, slots []Slot, p Params func (ceilinglessOptimizer) Close() error { return nil } -// A worker plan that overruns an hour falls back to Core's own plan. When -// Core cannot plan the site itself, here a battery below its floor, the -// worker's plan is published as before the hours, with a warning, rather -// than no plan at all. +// A worker plan that overruns an hour falls back to Core's own plan. A +// battery below its floor no longer stops Core from planning (#2043), so the +// plan stays inside the hour there too. func TestImportCeilingWorkerPlanOverrunsAnHour(t *testing.T) { for _, soc := range []float64{.5, .05} { t.Run(fmt.Sprintf("battery %.0f %%", soc*100), func(t *testing.T) { @@ -444,30 +443,25 @@ func TestImportCeilingWorkerPlanOverrunsAnHour(t *testing.T) { snap := svc.PlanSnapshot() got := planImportWh(*snap.Plan, start.UnixMilli(), start.Add(time.Hour).UnixMilli()) warned := strings.Contains(strings.Join(snap.Warnings, " "), "Core cannot plan this site itself") - if soc == .5 { - if !snap.Plan.Solver.Fallback || got > 4155 || warned { - t.Fatalf("solver %+v, 09:00 imports %.0f Wh, warned %v; want Core's plan inside the hour", snap.Plan.Solver, got, warned) - } - return - } - if snap.Plan.Solver.Fallback || got <= 4155 || !warned { - t.Fatalf("solver %+v, 09:00 imports %.0f Wh, warnings %q; want the worker's plan with a warning", snap.Plan.Solver, got, snap.Warnings) + if !snap.Plan.Solver.Fallback || got > 4155 || warned { + t.Fatalf("solver %+v, 09:00 imports %.0f Wh, warned %v; want Core's plan inside the hour", snap.Plan.Solver, got, warned) } }) } } -func TestNativeImportCeilingWhenCoreCannotPlan(t *testing.T) { +func TestNativeImportCeilingBelowTheFloor(t *testing.T) { worker := nativeWorker(t, 1500*time.Millisecond) t.Cleanup(func() { _ = worker.Close() }) - svc, _ := importCeilingFieldService(t, worker, true) + svc, start := importCeilingFieldService(t, worker, true) soc := .05 svc.Tele.Update("sungrow", telemetry.DerBattery, 0, &soc, nil) if svc.Replan(context.Background()) == nil { t.Fatalf("no plan published: %+v", svc.PlanSnapshot()) } - if w := strings.Join(svc.PlanSnapshot().Warnings, " "); !strings.Contains(w, "Core cannot plan this site itself") { - t.Fatalf("warnings %q", w) + snap := svc.PlanSnapshot() + if got := planImportWh(*snap.Plan, start.UnixMilli(), start.Add(time.Hour).UnixMilli()); got > 4155 { + t.Fatalf("09:00 imports %.0f Wh, warnings %q", got, snap.Warnings) } } diff --git a/go/internal/mpc/params_validation.go b/go/internal/mpc/params_validation.go index 3f99d75e6..cb587802f 100644 --- a/go/internal/mpc/params_validation.go +++ b/go/internal/mpc/params_validation.go @@ -73,11 +73,10 @@ func validateBatteryFleetMembers(fleet []BatteryFleetMember) error { return nil } -// planningParamsRequireRecovery marks states the external model represents -// directly, with an operating-band recovery ratchet, and the discrete Go DP -// does not: the DP snaps its initial SoC onto the operating grid, so solving -// from an out-of-band start plans from energy the site does not have (or -// discards energy it does have). +// planningParamsRequireRecovery marks a start outside the operating band. +// Replan clamps it onto the band edge for every planner: the discrete Go DP +// snaps its initial SoC onto the operating grid, and Energyplan 0.7.0 with a +// car kept such a battery idle for a whole horizon (#2043). func planningParamsRequireRecovery(p Params) bool { if p.CapacityWh == 0 && len(p.Storages) == 0 { return false @@ -94,8 +93,8 @@ func planningParamsRequireRecovery(p Params) bool { } // clampParamsIntoOperatingBand pulls a battery that has drifted outside -// soc_min…soc_max back onto the nearest band edge so the Core planner can plan -// at all, and records the real reading in InitialSoCUnclamped. It reports +// soc_min…soc_max back onto the nearest band edge so every planner can plan +// from it, and records the real reading in InitialSoCUnclamped. It reports // whether anything moved, and whether the state was recoverable. // // Why clamping beats refusing, which is what a reviewer will ask. The clamp @@ -105,9 +104,8 @@ func planningParamsRequireRecovery(p Params) bool { // the driver's own discharge floor, which exist because planner output is // never sent directly to hardware. Refusing leaves the site executing a stale // plan for hours and then falling back to live balancing, which is the worse -// failure. That was tolerable only while reaching this path required a missing -// optimizer; Core is the planner now. The field case is a Ferroamp driver -// floor at 0.10 with the pack settling at 0.09 overnight. +// failure. The field cases are a Ferroamp driver floor at 0.10 with the pack +// settling at 0.09 overnight, and a Pixii settling at 0.097 (#2043). // // Non-finite or physically impossible readings — SoC outside 0..1, storage // energy outside 0..capacity — are broken telemetry rather than a recoverable diff --git a/go/internal/mpc/params_validation_test.go b/go/internal/mpc/params_validation_test.go index 7ee03ecd5..5d069378c 100644 --- a/go/internal/mpc/params_validation_test.go +++ b/go/internal/mpc/params_validation_test.go @@ -424,10 +424,12 @@ func (*physicsGateCountingOptimizer) Close() error { return nil } type physicsGateRecoveryOptimizer struct { calls atomic.Int32 + got atomic.Pointer[Params] } func (o *physicsGateRecoveryOptimizer) Optimize(_ context.Context, slots []Slot, p Params) (Plan, error) { o.calls.Add(1) + o.got.Store(&p) plan := Plan{ GeneratedAtMs: time.Now().UnixMilli(), Mode: p.Mode, HorizonSlots: len(slots), CapacityWh: p.CapacityWh, @@ -681,119 +683,98 @@ func TestReplanRejectsInvalidPhysicsBeforeGoDP(t *testing.T) { } } -func TestReplanRecoveryUsesExternalPlannerWithoutDPDerivedResults(t *testing.T) { +// A battery below its floor reaches the worker on the band edge, as it +// reaches Core's own planner (#2043). Energyplan 0.7.0, given a start just +// under the floor and a car, kept the battery idle for the whole horizon. +func TestReplanGivesTheWorkerAnInBandStart(t *testing.T) { tests := []struct { name string setup func(*Service) }{ - {"aggregate recovery", func(svc *Service) { svc.Defaults.InitialSoC = 0.05 }}, - {"storage member recovery", func(svc *Service) { configurePhysicsGateFleet(svc, 0.05, 0.55) }}, + {"aggregate below the floor", func(svc *Service) { svc.Defaults.InitialSoC = 0.097 }}, + {"aggregate far below the floor", func(svc *Service) { svc.Defaults.InitialSoC = 0.01 }}, + {"storage member below the floor", func(svc *Service) { configurePhysicsGateFleet(svc, 0.05, 0.55) }}, } for _, tc := range tests { t.Run(tc.name, func(t *testing.T) { - st, err := state.Open(filepath.Join(t.TempDir(), "state.db")) - if err != nil { - t.Fatal(err) - } - defer st.Close() - now := time.Now().UTC().Truncate(time.Minute) - if err := st.SavePrices([]state.PricePoint{{ - Zone: "SE3", SlotTsMs: now.Add(-5 * time.Minute).UnixMilli(), SlotLenMin: 60, - SpotOreKwh: 50, TotalOreKwh: 100, Source: "test", FetchedAtMs: now.UnixMilli(), - }}); err != nil { - t.Fatal(err) - } - - p := validPlanningParams() - p.Mode = ModeArbitrage + svc := recoveryTestService(t) optimizer := &physicsGateRecoveryOptimizer{} - svc := New(st, nil, "SE3", p) - svc.BaseLoad = 500 svc.Optimizer = optimizer tc.setup(svc) plan := svc.Replan(context.Background()) if plan == nil || plan.Solver == nil || plan.Solver.Backend != "recovery" { - t.Fatalf("external recovery plan = %+v", plan) + t.Fatalf("worker plan = %+v", plan) } if optimizer.calls.Load() != 1 { - t.Fatalf("external optimizer calls = %d, want 1", optimizer.calls.Load()) + t.Fatalf("worker calls = %d, want 1", optimizer.calls.Load()) } - if plan.DPEvaluationShadow != nil || plan.DPShadow != nil || plan.Baselines != nil { - t.Fatalf("DP-derived results must be absent during recovery: evaluation=%+v downside=%+v baselines=%+v", - plan.DPEvaluationShadow, plan.DPShadow, plan.Baselines) + got := optimizer.got.Load() + if planningParamsRequireRecovery(*got) || got.InitialSoC < got.SoCMin { + t.Fatalf("worker got an out-of-band start: soc %.3f, min %.3f, storages %+v", got.InitialSoC, got.SoCMin, got.Storages) + } + if got.InitialSoCUnclamped == 0 { + t.Fatal("the real reading was not recorded") } }) } } -func TestReplanRecoveryKeepsPreviousPlanWhenDPWouldBeRequired(t *testing.T) { +// A worker that fails while the battery is below its floor must not leave +// the site on an old plan: Core plans from the band edge instead. (Core's +// planner cannot hold two storages at any charge, so a fleet keeps its +// previous plan either way.) +func TestReplanFallsBackToCoreWhenTheWorkerFailsBelowTheFloor(t *testing.T) { tests := []struct { - name string - baseline PlanOptimizer - recovery PlanOptimizer - wantFailCalls int32 - setupRecovery func(*Service) + name string + setup func(*Service) }{ - // Only the external-champion path still refuses: its operating-band - // recovery ratchet is what the DP cannot represent, so a failed primary - // must not silently become a DP plan solved from a snapped SoC. With - // Core as the configured planner the same state is clamped and planned - // — see TestCoreChampionClampsOutOfBandSoC. - {name: "aggregate failed primary", baseline: &physicsGateCountingOptimizer{}, recovery: &physicsGateFailingOptimizer{}, wantFailCalls: 1, - setupRecovery: func(svc *Service) { svc.Defaults.InitialSoC = 0.05 }}, - {name: "storage member failed primary", baseline: &physicsGateCountingOptimizer{}, recovery: &physicsGateFailingOptimizer{}, wantFailCalls: 1, - setupRecovery: func(svc *Service) { configurePhysicsGateFleet(svc, 0.05, 0.55) }}, + {"just below the floor", func(svc *Service) { svc.Defaults.InitialSoC = 0.097 }}, + {"far below the floor", func(svc *Service) { svc.Defaults.InitialSoC = 0.01 }}, } for _, tc := range tests { t.Run(tc.name, func(t *testing.T) { - st, err := state.Open(filepath.Join(t.TempDir(), "state.db")) - if err != nil { - t.Fatal(err) - } - defer st.Close() - now := time.Now().UTC().Truncate(time.Minute) - if err := st.SavePrices([]state.PricePoint{{ - Zone: "SE3", SlotTsMs: now.Add(-5 * time.Minute).UnixMilli(), SlotLenMin: 60, - SpotOreKwh: 50, TotalOreKwh: 100, Source: "test", FetchedAtMs: now.UnixMilli(), - }}); err != nil { - t.Fatal(err) - } - - p := validPlanningParams() - svc := New(st, nil, "SE3", p) - svc.BaseLoad = 500 - svc.Optimizer = tc.baseline - var idCalls, saveCalls atomic.Int32 - svc.decisionIDFactory = func() string { - idCalls.Add(1) - return "00000000-0000-4000-8000-000000000098" - } - svc.SaveDiag = func(*Diagnostic, string) error { - saveCalls.Add(1) - return nil - } + svc := recoveryTestService(t) + svc.Optimizer = &physicsGateCountingOptimizer{} accepted := svc.Replan(context.Background()) - if accepted == nil || accepted.DecisionID == "" { - t.Fatalf("baseline plan = %+v", accepted) + if accepted == nil { + t.Fatal("no baseline plan") } - - tc.setupRecovery(svc) - svc.Optimizer = tc.recovery + failing := &physicsGateFailingOptimizer{} + svc.Optimizer = failing + tc.setup(svc) got := svc.Replan(context.Background()) - if got != accepted || svc.Latest() != accepted { - t.Fatalf("recovery replaced prior plan through Go DP: got=%p accepted=%p latest=%p", - got, accepted, svc.Latest()) + if got == nil || got == accepted || svc.Latest() != got { + t.Fatalf("site kept the old plan: got=%p accepted=%p latest=%p", got, accepted, svc.Latest()) } - if idCalls.Load() != 1 || saveCalls.Load() != 1 { - t.Fatalf("calls after recovery rejection: id=%d save=%d, want 1/1", idCalls.Load(), saveCalls.Load()) + if got.Solver == nil || !got.Solver.Fallback || got.InitialSoC < svc.lastParams.SoCMin { + t.Fatalf("fallback plan = %+v from soc %.3f", got.Solver, got.InitialSoC) } - if failing, ok := tc.recovery.(*physicsGateFailingOptimizer); ok && failing.calls.Load() != tc.wantFailCalls { - t.Fatalf("failing optimizer calls = %d, want %d", failing.calls.Load(), tc.wantFailCalls) + if failing.calls.Load() != 1 { + t.Fatalf("failing worker calls = %d, want 1", failing.calls.Load()) } }) } } +func recoveryTestService(t *testing.T) *Service { + t.Helper() + st, err := state.Open(filepath.Join(t.TempDir(), "state.db")) + if err != nil { + t.Fatal(err) + } + t.Cleanup(func() { st.Close() }) + now := time.Now().UTC().Truncate(time.Minute) + if err := st.SavePrices([]state.PricePoint{{ + Zone: "SE3", SlotTsMs: now.Add(-5 * time.Minute).UnixMilli(), SlotLenMin: 60, + SpotOreKwh: 50, TotalOreKwh: 100, Source: "test", FetchedAtMs: now.UnixMilli(), + }}); err != nil { + t.Fatal(err) + } + svc := New(st, nil, "SE3", validPlanningParams()) + svc.BaseLoad = 500 + return svc +} + func TestReplanSnapshotsPVUncertaintyOnce(t *testing.T) { st, err := state.Open(filepath.Join(t.TempDir(), "state.db")) if err != nil { diff --git a/go/internal/mpc/service.go b/go/internal/mpc/service.go index d05429713..abef59fba 100644 --- a/go/internal/mpc/service.go +++ b/go/internal/mpc/service.go @@ -1957,11 +1957,14 @@ func (s *Service) runReplan(request replanRequest) *Plan { slog.Error("mpc: invalid optimization parameters; keeping previous plan", "err", err) return fail("inputs", err.Error()) } - recoveryRequired := planningParamsRequireRecovery(p) - if recoveryRequired && s.Optimizer == nil { - // Core is the planner, so this state has to produce a plan. Clamp onto - // the band edge and record the real reading; the argument for clamping - // over refusing is in clampParamsIntoOperatingBand. + if planningParamsRequireRecovery(p) { + // A battery outside its band still needs a plan, whichever planner + // runs. Clamp onto the band edge and record the real reading; the + // argument for clamping over refusing is in + // clampParamsIntoOperatingBand. The worker gets the clamped state too: + // Energyplan 0.7.0, given a start 0.1 Wh under the floor and a car, + // published an idle battery for the whole horizon (#2043), and a + // failed worker could not fall back to Core from an out-of-band start. clamped, ok := clampParamsIntoOperatingBand(&p) if !ok { slog.Error("mpc: battery state is not physically possible; keeping previous plan", @@ -1979,8 +1982,7 @@ func (s *Service) runReplan(request replanRequest) *Plan { "soc_max", p.SoCMax) } // The state is inside the band now, so this is an ordinary solve: - // baselines and shadows apply as usual. - recoveryRequired = false + // baselines, shadows and the Core fallback apply as usual. } slog.Info("mpc: optimize params", @@ -2085,7 +2087,7 @@ func (s *Service) runReplan(request replanRequest) *Plan { return s.canceledReplan(request, "primary-solve") } if err == nil { - if recoveryRequired || downsidePrimary || coreDPModelError(p) != nil { + if downsidePrimary || coreDPModelError(p) != nil { candidate.DPEvaluationShadow = nil candidate.DPShadow = nil candidate.Baselines = nil @@ -2138,7 +2140,7 @@ func (s *Service) runReplan(request replanRequest) *Plan { } plan = candidate - } else if overrun := (*planOverrun)(nil); errors.As(err, &overrun) && (recoveryRequired && !downsidePrimary || coreDPModelError(p) != nil) { + } else if overrun := (*planOverrun)(nil); errors.As(err, &overrun) && coreDPModelError(p) != nil { // Core cannot plan this site itself. The worker's plan keeps // every rule but the hours or the car's room. The live limit // still holds each hour, and the charger's room leaves battery @@ -2166,14 +2168,6 @@ func (s *Service) runReplan(request replanRequest) *Plan { if request.wasCanceledByService() { return s.canceledReplan(request, "primary-fallback") } - if recoveryRequired && !downsidePrimary { - slog.Error("mpc: primary optimizer failed and Go DP cannot model operating-bound recovery; keeping previous plan", - "err", err, - "soc_start", p.InitialSoC, - "soc_min", p.SoCMin, - "soc_max", p.SoCMax) - return fail("core_fallback", "Optimizer failed: "+err.Error()) - } if modelErr := coreDPModelError(p); modelErr != nil { slog.Error("mpc: primary failed and fallback cannot represent this site; keeping previous plan", "err", err, "fallback", modelErr) return fail("core_fallback", "Optimizer failed: "+err.Error()+"; fallback unavailable: "+modelErr.Error()) @@ -2262,7 +2256,7 @@ func (s *Service) runReplan(request replanRequest) *Plan { // self-consumption mode: the SC baseline is the plan itself, which // makes the badge trivially zero and distracts from the price // signal. For SC runs the UI still has the plan cost on its own. - if p.Mode != ModeSelfConsumption && !recoveryRequired && coreDPModelError(p) == nil && (plan.Solver == nil || (!plan.Solver.Fallback && plan.Solver.Backend != "ev_reserve")) { + if p.Mode != ModeSelfConsumption && coreDPModelError(p) == nil && (plan.Solver == nil || (!plan.Solver.Fallback && plan.Solver.Backend != "ev_reserve")) { bl := ComputeBaselines(slots, p) plan.Baselines = &bl }