From f83334306c65d4e8a0b07e919889ddcc2bba04c6 Mon Sep 17 00:00:00 2001 From: Segran Date: Wed, 18 Nov 2026 19:01:23 +0100 Subject: [PATCH 1/4] fix(web): show charger connection state in power flow --- .changeset/charger-connection-in-flow.md | 5 ++++ web/components/energy-flow-readings.js | 28 +++++++++++++++++---- web/components/ftw-energy-flow.js | 3 ++- web/energy-flow-readings.test.mjs | 32 ++++++++++++++++++++++++ 4 files changed, 62 insertions(+), 6 deletions(-) create mode 100644 .changeset/charger-connection-in-flow.md diff --git a/.changeset/charger-connection-in-flow.md b/.changeset/charger-connection-in-flow.md new file mode 100644 index 000000000..a25fb0434 --- /dev/null +++ b/.changeset/charger-connection-in-flow.md @@ -0,0 +1,5 @@ +--- +"ftw": patch +--- + +Show when a car is not connected in the power flow. An attached car with no power reading shows that it is connected and power data is missing. Control feedback preserves these connection states. diff --git a/web/components/energy-flow-readings.js b/web/components/energy-flow-readings.js index a251506fc..75b9aef94 100644 --- a/web/components/energy-flow-readings.js +++ b/web/components/energy-flow-readings.js @@ -181,17 +181,24 @@ export function flowReadingsFromStatus(status, opts) { } } - const evW = num(d.ev_w); - if (evW !== null) { + const disconnected = d.ev_connected === false; + const evW = disconnected ? 0 : num(d.ev_w); + if (evW !== null || typeof d.ev_connected === "boolean") { const active = !isIdle(evW, thresholdW); const planet = { id: `ev-${name}`, corner: "bottom-right", title: "EV CHARGER", role: "ev", name, kw: Math.abs(evW) / 1000, toHub: false, color: planetColor("ev", evW, thresholdW), - sub: active ? "charging" : "idle", + sub: disconnected ? "not connected" : active ? "charging" : "idle", clickable: true, }; - if (online) { + if (online && evW === null) { + live.ev = true; + planets.push(placeholderPlanet({ + id: planet.id, corner: planet.corner, title: planet.title, + role: planet.role, name, sub: "connected · no power data", clickable: true, + })); + } else if (online) { live.ev = true; planets.push(planet); } else { @@ -225,10 +232,21 @@ export function flowReadingsFromStatus(status, opts) { selfPoweredPctToday = Math.max(0, Math.min(100, (1 - importWh / loadWh) * 100)); } + const markedPlanets = withControlMarks(planets, status?.control_feedback, opts?.live !== false); + for (const planet of markedPlanets) { + const driver = status?.drivers?.[planet.name]; + if (planet.role !== "ev" || !driverOnline(driver) || opts?.live === false) continue; + if (driver?.ev_connected === false) { + Object.assign(planet, {placeholder: false, kw: 0, sub: "not connected"}); + } else if (driver?.ev_connected === true && num(driver.ev_w) === null) { + planet.sub = "connected · no power data"; + } + } + return { load: loadW === null ? null : loadW / 1000, loadEstimated: hasEstimate, - planets: withControlMarks(planets, status?.control_feedback, opts?.live !== false), + planets: markedPlanets, selfPoweredPctToday, }; } diff --git a/web/components/ftw-energy-flow.js b/web/components/ftw-energy-flow.js index c17acf4b0..aeb7a3db0 100644 --- a/web/components/ftw-energy-flow.js +++ b/web/components/ftw-energy-flow.js @@ -1703,7 +1703,8 @@ function aggregateGroups(groups) { } else if (first.role === "pv") { sub = idle ? "idle" : "generating"; } else if (first.role === "ev") { - sub = idle ? "idle" : "charging"; + sub = group.every(p => p.sub === "not connected") ? "not connected" + : idle ? "idle" : "charging"; } // SoC: simple mean across reporters. Real weighting needs per- // battery capacity, which the component doesn't have here — the diff --git a/web/energy-flow-readings.test.mjs b/web/energy-flow-readings.test.mjs index 2977a3f10..b4ea81649 100644 --- a/web/energy-flow-readings.test.mjs +++ b/web/energy-flow-readings.test.mjs @@ -245,3 +245,35 @@ it("draws Core's estimated Home use as an estimate, not a blank", () => { assert.equal(result.loadEstimated, true); assert.equal(flowReadingsFromStatus({load_w: 980, load_quality: "measured"}).loadEstimated, false); }); + +it("shows an unplugged charger even without power and preserves connected idle", () => { + for (const ev_w of [null, 0, 1000]) { + const r = flowReadingsFromStatus({drivers:{easee:{status:"ok",ev_connected:false,ev_w}}}); + const ev = r.planets.find(p => p.id === "ev-easee"); + assert.equal(ev.sub, "not connected"); + assert.equal(ev.kw, 0); + } + const r = flowReadingsFromStatus({drivers:{easee:{status:"ok",ev_connected:true,ev_w:0}}}); + assert.equal(r.planets.find(p => p.id === "ev-easee").sub, "idle"); +}); + +it("keeps a known connected state when charger power is unavailable", () => { + const r = flowReadingsFromStatus({drivers:{easee:{status:"ok",ev_connected:true,ev_w:null}}}); + const ev = r.planets.find(p => p.id === "ev-easee"); + assert.equal(ev.sub, "connected · no power data"); + assert.equal(ev.placeholder, true); +}); + +it("keeps charger connection information when control feedback has no power", () => { + const feedback = {driver:"easee",kind:"ev",status:"waiting",severity:"info",readings_fresh:false}; + const status = {drivers:{easee:{status:"ok",ev_connected:false,ev_w:null}}, + control_feedback:[{...feedback,reason:"not_connected"}]}; + const disconnected = flowReadingsFromStatus(status).planets.find(p => p.id === "ev-easee"); + assert.equal(disconnected.sub, "not connected"); + assert.equal(disconnected.placeholder, false); + status.drivers.easee.ev_connected = true; + status.control_feedback[0].reason = "telemetry_stale"; + const connected = flowReadingsFromStatus(status).planets.find(p => p.id === "ev-easee"); + assert.equal(connected.sub, "connected · no power data"); + assert.equal(connected.placeholder, true); +}); From 13204bd5160e446d7e02ba8101e4a67b02178df0 Mon Sep 17 00:00:00 2001 From: Segran Date: Sat, 21 Nov 2026 15:22:34 +0100 Subject: [PATCH 2/4] fix(web): shorten connected charger label Signed-off-by: Segran --- web/components/energy-flow-readings.js | 4 ++-- web/energy-flow-readings.test.mjs | 4 ++-- 2 files changed, 4 insertions(+), 4 deletions(-) diff --git a/web/components/energy-flow-readings.js b/web/components/energy-flow-readings.js index 75b9aef94..dc4d61ec4 100644 --- a/web/components/energy-flow-readings.js +++ b/web/components/energy-flow-readings.js @@ -196,7 +196,7 @@ export function flowReadingsFromStatus(status, opts) { live.ev = true; planets.push(placeholderPlanet({ id: planet.id, corner: planet.corner, title: planet.title, - role: planet.role, name, sub: "connected · no power data", clickable: true, + role: planet.role, name, sub: "connected · no data", clickable: true, })); } else if (online) { live.ev = true; @@ -239,7 +239,7 @@ export function flowReadingsFromStatus(status, opts) { if (driver?.ev_connected === false) { Object.assign(planet, {placeholder: false, kw: 0, sub: "not connected"}); } else if (driver?.ev_connected === true && num(driver.ev_w) === null) { - planet.sub = "connected · no power data"; + planet.sub = "connected · no data"; } } diff --git a/web/energy-flow-readings.test.mjs b/web/energy-flow-readings.test.mjs index b4ea81649..1768730b5 100644 --- a/web/energy-flow-readings.test.mjs +++ b/web/energy-flow-readings.test.mjs @@ -260,7 +260,7 @@ it("shows an unplugged charger even without power and preserves connected idle", it("keeps a known connected state when charger power is unavailable", () => { const r = flowReadingsFromStatus({drivers:{easee:{status:"ok",ev_connected:true,ev_w:null}}}); const ev = r.planets.find(p => p.id === "ev-easee"); - assert.equal(ev.sub, "connected · no power data"); + assert.equal(ev.sub, "connected · no data"); assert.equal(ev.placeholder, true); }); @@ -274,6 +274,6 @@ it("keeps charger connection information when control feedback has no power", () status.drivers.easee.ev_connected = true; status.control_feedback[0].reason = "telemetry_stale"; const connected = flowReadingsFromStatus(status).planets.find(p => p.id === "ev-easee"); - assert.equal(connected.sub, "connected · no power data"); + assert.equal(connected.sub, "connected · no data"); assert.equal(connected.placeholder, true); }); From 447cc8a2fc4002f11e7986f8b2b619099bb787fc Mon Sep 17 00:00:00 2001 From: Segran Date: Sat, 21 Nov 2026 15:29:53 +0100 Subject: [PATCH 3/4] fix(web): fit charger status inside the mobile ring Signed-off-by: Segran --- web/components/ftw-energy-flow.js | 14 +++++++++++++- 1 file changed, 13 insertions(+), 1 deletion(-) diff --git a/web/components/ftw-energy-flow.js b/web/components/ftw-energy-flow.js index aeb7a3db0..bcf041275 100644 --- a/web/components/ftw-energy-flow.js +++ b/web/components/ftw-energy-flow.js @@ -443,7 +443,10 @@ class FtwEnergyFlow extends FtwElement { .sv-hub-label { font-size: 11px; } .sv-hub-sub { font-size: 10px; } } + .sv-ev-status-compact { display: none; } @media (max-width: 600px) { + .sv-ev-status-wide { display: none; } + .sv-ev-status-compact { display: inline; } svg { height: calc(var(--efl-h-factor, 1) * 460px); } :host([embedded]) .ef-toggle { bottom: 30px; @@ -1596,6 +1599,14 @@ function renderCircleNode({ pos, title, nameLabel, value, sub, color, soc, // stroke/fill in the icon SVG. const iconSvg = ROLE_ICON[role] || ROLE_ICON.unknown; const iconScale = r * 0.45 / 10; + const splitEVStatus = role === "ev" && sub === "connected · no data"; + const compactEVStatus = splitEVStatus + ? ` + connected + no data + ` + : ""; return ` ` : ""} + fill="var(--hero-sub-text)" class="sv-node-sub${splitEVStatus ? " sv-ev-status-wide" : ""}"> ${escapeXml(sub)} + ${compactEVStatus} ${socText} `; } From 4cbd19f7698b3198bd04e09c2fc81f9993715c17 Mon Sep 17 00:00:00 2001 From: Segran Date: Sun, 22 Nov 2026 13:14:45 +0100 Subject: [PATCH 4/4] docs(web): explain why EV disconnect overrides power Signed-off-by: Segran --- web/components/energy-flow-readings.js | 1 + 1 file changed, 1 insertion(+) diff --git a/web/components/energy-flow-readings.js b/web/components/energy-flow-readings.js index dc4d61ec4..28cf3e425 100644 --- a/web/components/energy-flow-readings.js +++ b/web/components/energy-flow-readings.js @@ -182,6 +182,7 @@ export function flowReadingsFromStatus(status, opts) { } const disconnected = d.ev_connected === false; + // An explicit disconnect takes precedence over any lingering power reading. const evW = disconnected ? 0 : num(d.ev_w); if (evW !== null || typeof d.ev_connected === "boolean") { const active = !isIdle(evW, thresholdW);