Turn DC–DC converter test exports into traceable data, reproducible analysis, and offline reports.
中文入门 · Methodology · Architecture · Download demo HTML
Generated by the real analysis pipeline from synthetic fixtures—not a device performance claim.
An engineering bench can produce hundreds of useful measurements—and an equally large collection of awkward PDFs and positional log files. Manually moving curves into a spreadsheet loses context: which channel, operating mode, source file, and actual load produced each point?
This project redevelops a practical Python workflow originally used for power-module characterization. It keeps the electrical context while adding explicit data contracts, failure isolation, regression tests, a distributable package, and a repeatable command line. It is a portfolio project grounded in test engineering, not a claim of a production-certified measurement system.
All committed demo data is synthetic. No employer PDFs, original spreadsheets, personal CV, confidential product identifiers, or real measurements are distributed. The synthetic loss equation is illustrative, not fitted to a device.
Python 3.11 or newer; Windows, Linux, or macOS. From a checkout of this repository:
python -m venv .venv
# Windows PowerShell: .venv\Scripts\Activate.ps1
# macOS / Linux: source .venv/bin/activate
python -m pip install -e ".[dev]"
powerbench demo --output outputs/demo --legacy-wideOpen outputs/demo/report.html in your browser. The demo generates 8 runs × 12 points, an intentionally undefined efficiency reading, and traceable diagnostics. It needs no network connection after dependencies are installed. Each invocation requires a new or empty output directory; existing files are never overwritten.
The report includes:
- Like-for-like curve selection with fixed sample, channel, nominal output, frequency, and mode.
- Efficiency, output-voltage and loss views; linear/logarithmic load axes.
- Point inspection with source, page, table, row, and SHA-256 provenance.
- Per-run summaries, matched-load line regulation, and a searchable quality log.
GitHub does not execute HTML in the file viewer. Download the demo HTML and open it locally, or generate it with the command above.
| Stage | What the project does |
|---|---|
| Ingest | Born-digital ATE PDFs, versioned table JSON, UTF-8/UTF-16 voltage logs |
| Validate | Required columns, finite numbers, explicit units, efficiency/power consistency, duplicate loads |
| Analyze | Peak efficiency, signed load-regulation deviations, comparable-condition grouping, matched-load line regulation |
| Export | Tidy CSV, structured JSON, styled Excel with an XY chart, SVG/PNG plots, self-contained HTML |
| Audit | Source hashes, row/table/page locations, per-file diagnostics, configuration and artifact manifest |
| Operate | Installable CLI, strict validation mode, optional recursive discovery, no overwrite by default |
Numerical care matters: reported efficiency is not silently replaced with Pout / Pin; inf becomes a flagged missing value, not zero. Line regulation uses actual common load values, not the midpoint row of two unrelated arrays. Replicates and ambiguous duplicate loads are never silently averaged.
# Validate only: no files are created.
powerbench validate ./inputs --json
# Analyze a top-level folder; add --recursive only if needed.
powerbench analyze ./inputs --output outputs/run-01 --config examples/settings.toml
# Match specific actual loads, and produce logarithmic plots in amperes.
powerbench analyze ./inputs --output outputs/run-02 --loads 0,1,2 --log-x
# Compare operating modes instead of input voltages in static figures.
powerbench analyze ./inputs --output outputs/modes --vary mode --formats html,csv,plots
# Return nonzero even on warnings; useful in automated quality gates.
powerbench validate ./inputs --strict
# Voltage logs: explicit positional headers prevent accidental column shifts.
powerbench logs examples/synthetic-voltage.txt --output outputs/logs \
--headers examples/voltage-headers.jsonpython -m powerbench is equivalent to powerbench if you prefer an explicit interpreter.
Filename:
[__]sample_channel_Vin_Vout_frequency-kHz_mode[_EFFI_YYYY-MM-DD HH-MM-SS].pdf
__DEMO_1_10_5_500_1_EFFI_2026-01-01 12-00-00.pdf
Native table columns: No. Io Vo Vi Ii Po Pi Ploss Effi. Column order may change; the full recognized header is required. Data is normalized to A, V, W, kHz and efficiency fraction. channel=S means merged output. Mode IDs are preserved; customize labels only when verified against your device documentation.
Units are a declared adapter convention, not inferred from number magnitudes. Use efficiency_unit = "percent" only for a source that truly reports percentages. mA/mV table inputs, arbitrary PDF layouts, scanned/OCR-only PDFs, encrypted files, and arbitrary spreadsheet ingestion are not supported by this release. See methodology and limits.
outputs/run-01/
├── report.html # Offline, interactive, no telemetry or CDN
├── analysis.xlsx # Measurements / Summary / Line Regulation / Diagnostics / Read Me
├── measurements.csv # One row per observation; conditions and units retained
├── summary.csv
├── line_regulation.csv
├── results.json # Versioned data plus analysis and diagnostics
├── diagnostics.json # Always written, including failed batches
├── manifest.json # Input and output hashes + effective settings
└── plots/ # One comparable-condition chart per group, SVG and PNG
--legacy-wide adds labelled alternating load/efficiency rows for compatibility with older curve-oriented spreadsheet workflows. It is not the primary data model.
Exit status: 0 = completed without errors; 1 = data errors/no valid runs, or any diagnostic under --strict; 2 = usage/configuration/I/O failure. In non-strict mode, good files survive a failed neighbour and the batch still returns failure if any data error occurred. Review diagnostics.json before drawing conclusions.
- Immutable domain objects: test conditions and observations are separate from parsing and presentation.
- Inspectable algorithms: pure-Python interpolation, explicit mean-normalized regulation, no accidental extrapolation.
- Defensive boundaries: unsupported schemas fail; headers and units are not guessed; malformed rows produce errors.
- Safe artifacts: CSV formula-prefix escaping, literal Excel strings, escaped embedded JSON, no report network access.
- Automated verification: formula, parser, batch, log, CLI, serialization, injection, and export regression tests.
- CI: quality checks plus Python 3.11–3.13 tests on Linux and Windows, with generated demo artifacts.
python -m pytest --cov=powerbench --cov-report=term-missing
ruff check .
ruff format --check .
mypy src/powerbench
python -m buildThe public test suite uses synthetic tables and PDF-reader boundary doubles. Local reference checks against privately extracted historical reports are not committed. CI configuration is not a claim that every platform has already been verified; the badge shows actual runs.
This release focuses on one known ATE report family and a defensive voltage-log adapter. Extensions worth adding are vendor-specific adapters, explicit replicate selection/aggregation policies, uncertainty propagation, and an agreed device-specification pass/fail layer. It intentionally does not control lab instruments or make release decisions.