Inofficial Library for basic communication to bluetti powerstations via Modbus.
Based on official documentation https://github.com/bluetti-official/bluetti-modbus-tcp-slave
You have to enable Modbus TCP in the webinterface of your device first.
This library is provided without any warranty or support by Bluetti. I do not take responsibility for any problems it may cause in all cases. Use it at your own risk.
TBD
pip install bluetti-modbus-libIf you want to support this project and buy a bluetti device, you can use the sponsors button on github:
Note
DE: Bei diesem Link handelt es sich um einen Affiliate-Link. Wenn du darüber kaufst, erhalte ich eine kleine Provision. Für dich entstehen keine Zusatzkosten.
EN: This is an affiliate link. If you make a purchase through it, I may earn a small commission at no extra cost to you.
Commands included in this library should only be used for testing.
usage: bluetti-modread [-h] [-c HOST] [-p PORT] [-t TYPE]
Read bluetti devices via modbus
options:
-h, --help show this help message and exit
-c HOST, --host HOST IP-address of the device
-p PORT, --port PORT Port of the device
-t TYPE, --type TYPE Device typeExample:
bluetti-modread -c 10.2.1.60 -p 502 -t balco260Example output:
ac_o_e_total: 277.3 kWh (category: n/a) (state_class: FieldStateClass.TOTAL_INCREASING) (device_class: DeviceClass.ENERGY)
ac_o_p_total: 429 W (category: n/a) (state_class: FieldStateClass.MEASUREMENT) (device_class: DeviceClass.POWER)
ac_o_switch: 0 (category: n/a) (state_class: n/a) (device_class: n/a)
b_c: 2982.6 A (category: n/a) (state_class: FieldStateClass.MEASUREMENT) (device_class: DeviceClass.CURRENT)
b_c_total: 17.3 A (category: n/a) (state_class: FieldStateClass.MEASUREMENT) (device_class: DeviceClass.CURRENT)
b_cell_count: 8 (category: FieldCategory.DIAGNOSTIC) (state_class: n/a) (device_class: n/a)
b_cycle_count: 25 (category: FieldCategory.DIAGNOSTIC) (state_class: n/a) (device_class: n/a)
b_i_e: 67.25 kWh (category: n/a) (state_class: FieldStateClass.TOTAL_INCREASING) (device_class: DeviceClass.ENERGY)
b_ntc_count: 4 (category: FieldCategory.DIAGNOSTIC) (state_class: n/a) (device_class: n/a)
b_o_e: 61.17 kWh (category: n/a) (state_class: FieldStateClass.TOTAL_INCREASING) (device_class: DeviceClass.ENERGY)
b_soc: 71 % (category: n/a) (state_class: FieldStateClass.MEASUREMENT) (device_class: DeviceClass.BATTERY)
b_soc_high: 100 % (category: FieldCategory.CONFIG) (state_class: n/a) (device_class: n/a)
b_soc_low: 50 % (category: FieldCategory.CONFIG) (state_class: n/a) (device_class: n/a)
b_soc_total: 0 % (category: n/a) (state_class: FieldStateClass.MEASUREMENT) (device_class: DeviceClass.BATTERY)
b_soh: 99 % (category: FieldCategory.DIAGNOSTIC) (state_class: FieldStateClass.MEASUREMENT) (device_class: n/a)
b_soh_total: 0 % (category: FieldCategory.DIAGNOSTIC) (state_class: FieldStateClass.MEASUREMENT) (device_class: n/a)
b_t_avg: 0 °C (category: FieldCategory.DIAGNOSTIC) (state_class: FieldStateClass.MEASUREMENT) (device_class: DeviceClass.TEMPERATURE)
b_type: Balco260 (category: n/a) (state_class: n/a) (device_class: n/a)
b_v: 26.1 V (category: n/a) (state_class: FieldStateClass.MEASUREMENT) (device_class: DeviceClass.VOLTAGE)
b_v_total: 26.1 V (category: n/a) (state_class: FieldStateClass.MEASUREMENT) (device_class: DeviceClass.VOLTAGE)
d_inverter_fault: InverterFault.NoFault (category: FieldCategory.DIAGNOSTIC) (state_class: n/a) (device_class: n/a)
d_inverter_status: InverterStatus.GridConnectedDischarging (category: FieldCategory.DIAGNOSTIC) (state_class: n/a) (device_class: n/a)
d_inverter_total: 432 W (category: n/a) (state_class: FieldStateClass.MEASUREMENT) (device_class: DeviceClass.POWER)
d_inverter_type: Balco260 (category: FieldCategory.DIAGNOSTIC) (state_class: n/a) (device_class: n/a)
d_inverter_warning: InverterWarning.NoWarning (category: FieldCategory.DIAGNOSTIC) (state_class: n/a) (device_class: n/a)
d_num_battery_packs: 0 (category: FieldCategory.DIAGNOSTIC) (state_class: n/a) (device_class: n/a)
d_num_inverters: 1 (category: FieldCategory.DIAGNOSTIC) (state_class: n/a) (device_class: n/a)
g_i_e_total: 258.4 kWh (category: n/a) (state_class: FieldStateClass.TOTAL_INCREASING) (device_class: DeviceClass.ENERGY)
g_i_f: 50.0 Hz (category: n/a) (state_class: FieldStateClass.MEASUREMENT) (device_class: DeviceClass.FREQUENCY)
g_i_p_total: 0 W (category: n/a) (state_class: FieldStateClass.MEASUREMENT) (device_class: DeviceClass.POWER)
g_i_switch: 1 (category: FieldCategory.CONFIG) (state_class: n/a) (device_class: n/a)
g_o_e_total: 29.5 kWh (category: n/a) (state_class: FieldStateClass.TOTAL_INCREASING) (device_class: DeviceClass.ENERGY)
g_o_switch: 1 (category: FieldCategory.CONFIG) (state_class: n/a) (device_class: n/a)
pv_1_i_c: 0.0 A (category: n/a) (state_class: FieldStateClass.MEASUREMENT) (device_class: DeviceClass.CURRENT)
pv_1_i_p: 0 W (category: n/a) (state_class: FieldStateClass.MEASUREMENT) (device_class: DeviceClass.POWER)
pv_1_i_v: 0.0 V (category: n/a) (state_class: FieldStateClass.MEASUREMENT) (device_class: DeviceClass.VOLTAGE)
pv_2_i_c: 0.0 A (category: n/a) (state_class: FieldStateClass.MEASUREMENT) (device_class: DeviceClass.CURRENT)
pv_2_i_p: 0 W (category: n/a) (state_class: FieldStateClass.MEASUREMENT) (device_class: DeviceClass.POWER)
pv_2_i_v: 0.0 V (category: n/a) (state_class: FieldStateClass.MEASUREMENT) (device_class: DeviceClass.VOLTAGE)
pv_3_i_c: 0.0 A (category: n/a) (state_class: FieldStateClass.MEASUREMENT) (device_class: DeviceClass.CURRENT)
pv_3_i_p: 0 W (category: n/a) (state_class: FieldStateClass.MEASUREMENT) (device_class: DeviceClass.POWER)
pv_3_i_v: 42.9 V (category: n/a) (state_class: FieldStateClass.MEASUREMENT) (device_class: DeviceClass.VOLTAGE)
pv_4_i_c: 0.0 A (category: n/a) (state_class: FieldStateClass.MEASUREMENT) (device_class: DeviceClass.CURRENT)
pv_4_i_p: 0 W (category: n/a) (state_class: FieldStateClass.MEASUREMENT) (device_class: DeviceClass.POWER)
pv_4_i_v: 43.3 V (category: n/a) (state_class: FieldStateClass.MEASUREMENT) (device_class: DeviceClass.VOLTAGE)
pv_ac_e: 8.6 kWh (category: n/a) (state_class: FieldStateClass.TOTAL_INCREASING) (device_class: DeviceClass.ENERGY)
pv_ac_p: 0 W (category: n/a) (state_class: FieldStateClass.MEASUREMENT) (device_class: DeviceClass.POWER)
pv_i_e_total: 77.4 kWh (category: n/a) (state_class: FieldStateClass.TOTAL_INCREASING) (device_class: DeviceClass.ENERGY)
pv_i_p_total: 0 W (category: n/a) (state_class: FieldStateClass.MEASUREMENT) (device_class: DeviceClass.POWER)usage: bluetti-modwrite [-h] [-c HOST] [-p PORT] [-t TYPE] [-f FIELD] [-v VALUE]
Write to bluetti device field via modbus
options:
-h, --help show this help message and exit
-c, --host HOST IP-address of the device
-p, --port PORT Port of the device
-t, --type TYPE Device type
-f, --field FIELD Field name
-v, --value VALUE Value to writeExample:
This turns on the AC outlet on the Balco260
bluetti-modwrite -c 10.2.1.60 -p 502 -t balco260 -f ac_o_switch -v 1Example output: