Skip to content
Merged
Show file tree
Hide file tree
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension


Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
23 changes: 22 additions & 1 deletion CHANGELOG.md
Original file line number Diff line number Diff line change
Expand Up @@ -7,6 +7,13 @@ and this project adheres to [Semantic Versioning](https://semver.org/spec/v2.0.0

## [Unreleased]

## [0.4.7] - 2026-11-20

Bundled firmware is unchanged (leader 1.2.7 / follower 1.2.17). The fisheye
calibration resolution needs firmware 1.3.0-rc1 or later (release 1.3.1) and
high-rate IMU needs 1.3.0-rc2; those candidates are not bundled. Capabilities
are probed, so this SDK runs on 1.2.17 unchanged.

### Fisheye calibration resolution (protocol V2.10)

The wrist fisheye default moved from 640x480 to 1920x1080. Those are different
Expand Down Expand Up @@ -66,6 +73,20 @@ calibration resolution next to the 8 params, via two new ops on
`FisheyeUndistorter(cal, size, balance)` still treats the params as a
640x480 calibration.

#### Fixed

- **Calibration reads on real firmware no longer throw where they should
branch.** Firmware sends every handler error on the cmd=0 pure-ACK path,
which `send_cmd` raises as `NackError`, so the `CalNotSet` and
`InvalidParam` branches never ran on hardware. On a 1.2.17 follower
`supports_fisheye_size()` threw `NACK: InvalidParam`, and
`resolve_fisheye()` silently fell back to the reference intrinsics,
discarding the unit's own calibration. `read_fisheye()` and
`read_fisheye_record()` on a never-calibrated unit now return `None`, as
documented, instead of raising `ProtocolError('NACK: CalNotSet')`; other
NACKs read `Calibration::<method> NACK: <code>`. Both test fakes used to
answer errors with the command echoed and now use the firmware's path.

### ForcePositionController grip intent (2026-11-19)

#### Added
Expand All @@ -89,7 +110,7 @@ calibration resolution next to the 8 params, via two new ops on
arrival_eps_rad` (static, read-only): the arrival band, so callers do not
copy the private constant.

### High-rate IMU (candidate, not yet versioned; on top of 0.4.6)
### High-rate IMU (needs firmware 1.3.0-rc2)

Requires firmware 1.3.0-rc2 (both roles, reports 1.3.0.2; tc-gu-01 #30, on
top of 1.3.0-rc1, so it also carries the fisheye calibration resolution) for
Expand Down
2 changes: 1 addition & 1 deletion pyproject.toml
Original file line number Diff line number Diff line change
Expand Up @@ -4,7 +4,7 @@ build-backend = "scikit_build_core.build"

[project]
name = "taccap-gripper"
version = "0.4.6"
version = "0.4.7"
description = "TacCap-Gripper multimodal tactile gripper SDK"
readme = "README.md"
requires-python = ">=3.10"
Expand Down
Loading