PowerEye

PowerEye is a lightweight command-line utility for measuring power consumption using Intel's RAPL (Running Average Power Limit) interface, with optional NVIDIA GPU (NVML) and IPMI sources. It is implemented in C and built with CMake.

Features

  • CPU package power & energy via Intel RAPL (all sockets are summed)
  • Optional DRAM domain power & energy (-d)
  • Optional system-wide power via IPMI (-I)
  • Optional GPU total and per-GPU power & energy via NVIDIA NVML (-f g, -f G)
  • Self-overhead reporting (-f o): CPU time, scheduled wakeups and RAPL reads of power_eye itself
  • Adaptive sampling interval (-A): doubles while power is steady, returns to the base interval on change
  • Optional eBPF sampler (-B): reads RAPL on CPU idle exits, so observing an idle system does not wake extra CPUs
  • Long-idle ("coma") candidate detection (-C) from window power and package C6 residency
  • Benchmark harness for the observer effect of monitoring tools (tools/bench)
  • Per-process attribution (-p <pid>): CPU energy is split by each pid's CPU utilization, and GPU energy is split by each pid's nvmlDeviceGetProcessUtilization SM utilization, weighted by per-device power on multi-GPU systems

Requirements

  • OS: Linux with /sys/class/powercap (RAPL) support. Reading energy_uj may require root or a udev rule.
  • CPU: Intel processor with RAPL package—and optionally DRAM—domains
  • GPU (optional): NVIDIA driver + NVML (libnvidia-ml.so) if using -f g/-f G
  • eBPF sampler (optional): libbpf-dev and clang at build time, root and a kernel with RAPL perf events (/sys/bus/event_source/devices/power) at run time, if using -B
  • IPMI (optional): a BMC exposed through the kernel IPMI driver (/dev/ipmi0, /dev/ipmi/0 or /dev/ipmidev/0) if using -I; ipmitool is not required

Build Instructions

Make sure you have CMake (version 3.22 or higher) and a C compiler installed.

git clone https://github.com/energyawareOS/power_eye.git
cd power_eye
cmake -B build
cmake --build build

After building, the executable will be available at build/src/power_eye. The examples below call it as power_eye; use that path or copy it into your PATH. Unit tests: ctest --test-dir build (after cmake --build build).

Build variants

  • CPU-only (no NVML dependency)
cmake -B build -DCMAKE_BUILD_TYPE=Release
cmake --build build
  • NVML-enabled build (adds GPU monitoring)
cmake -B build -DUSE_NVML=ON -DCMAKE_BUILD_TYPE=Release
cmake --build build
  • eBPF sampler build (adds -B)
cmake -B build -DUSE_BPF=ON -DCMAKE_BUILD_TYPE=Release
cmake --build build

USE_BPF=ON needs libbpf (found with pkg-config) and clang; the BPF object is compiled during the build and embedded in the executable. Without it, -B prints a message and sysfs is used.

USE_NVML=ON requires the CUDA toolkit's nvml headers/library. Adjust include/lib paths for your distribution if CMake cannot find them (e.g., /usr/local/cuda/include, /usr/local/cuda/lib64).

Usage

power_eye [-i <interval>] [-t <timeout>] [-d] [-I] [-B] [-p <pid>]... [-A <max>] [-T <watts>] [-C <hours>] [-W <sec>] [-D <watts>] [-R <percent>] [-F <watts>] [-f <specs>] [-h]

Options:

  • -i <interval>: Sampling interval in seconds; fractional values such as 0.5 are accepted, invalid or sub-millisecond values are rejected (default: 1)
  • -t <timeout>: Total measurement duration in seconds (default: 120)
  • -A <max>: Adaptive sampling interval. -i is the base interval. While the measured power stays within a tolerance band of the running mean, the next interval doubles up to <max> seconds; as soon as a sample leaves the band it returns to -i and the band restarts at the new level. The cap is lowered to the RAPL counter wrap bound (max_energy_range_uj / max power / 2, from powercap; domains that do not report a maximum power are assumed to reach 300 W for packages and 100 W for DRAM, so -d can lower the cap) so no energy is lost between reads. An INT(s) column at the end of every row gives the length of that row's interval. Rows still report power/energy averaged over their own interval.
  • -T <watts>: Tolerance band for -A: a change is a sample more than max(<watts>, 3% of the mean) away from the mean of the current quiet period (default 1.0 W).
  • -C <hours>: Long-idle ("coma") detection; see below. Reports a coma candidate after <hours> (fractions allowed) of consecutive idle windows. Needs -B for package C-state residency; use it with -A so the node is sampled rarely while idle.
  • -W <sec>: Window length for -C (default 600).
  • -D <watts>: A window is idle if its mean package power is at most the idle floor plus this (default 1.0).
  • -R <percent>: ... and its deep package C-state (C6) residency, averaged over packages, is at least this (default 80).
  • -F <watts>: Idle power floor. By default it is learned as the lowest mean power of windows that meet the residency condition, so a busy start cannot define it; give it explicitly for a reliable verdict.
  • -d: Enable DRAM power/energy, summed over all sockets (if no DRAM RAPL domain exists, a warning is printed and DRAM is disabled)
  • -B: Read the RAPL energy counters from an eBPF sampler instead of sysfs (needs a USE_BPF=ON build and root; falls back to sysfs with a message if it cannot start). A BPF program on the cpu_idle tracepoint reads the package (and with -d DRAM) energy perf events on the idle exit of whichever CPU of a package wakes first, at most once per a tenth of the interval (10 ms .. 10 s), so reading does not wake any CPU by IPI. power_eye only reads the latest sample at each tick; if it is older than half an interval it takes one itself, on a CPU of that package (this is what OBS-RAPLRD counts with -B). Power is energy divided by the time between the samples used, so a row's (J) covers about one interval (not exactly), and the first row uses a sample taken at start.
  • -I: Enable IPMI power measurement
  • -p <pid>: Monitor a specific process by PID. May be given multiple times.
  • -f <specs>: Field/output specs. <specs> is a string of letters (e.g. -f cEH):
    • d: Prepend MM-dd to the timestamp
    • c: Include CPU power/energy columns
    • g: Include GPU total power/energy columns (requires USE_NVML=ON)
    • G: Include per-GPU columns; implies g
    • E: Include energy (J) columns in addition to power (W)
    • H: Print a one-line header describing the output columns
    • o: Report the cost of the observation itself (see below)
  • -h: Show help and exit

Output Schema

Timestamp

  • Default: HH:MM:SS
  • With -f d: MM-DD HH:MM:SS

Columns (by flags)

  • CPU only (-f c):

    [time] CPU(W)
    
  • CPU with energy (-f cE):

    [time] CPU(W) CPU(J)
    
  • CPU + DRAM (-d -f c):

    [time] CPU(W) DRAM(W)
    
  • CPU + DRAM with energy (-d -f cE):

    [time] CPU(W) CPU(J) DRAM(W) DRAM(J)
    
  • Add GPU total (-f cg):

    [time] CPU(W) GPU(W) [GPU(J) if E]
    
  • Add per-GPU (-f cG):

    [time] CPU(W) GPU(W) [GPU(J)] GPU00(W) [GPU00(J)] GPU01(W) [GPU01(J)] ...
    
  • IPMI (-I): The IPMI columns come after the GPU columns and before the per-process columns, matching the header order:

    ... IPMI(W) [IPMI(J)] ...
    

    If a reading fails, - is printed in place of each value so the column count stays constant.

  • Per-process attribution (-p <pid>): Per-pid columns are appended at the end. Without GPU, each pid contributes one (or two with E) columns:

    ... PID<n>(W) [PID<n>(J)] ...
    

    With GPU enabled (-f g or -f G), each pid contributes CPU and GPU columns:

    ... PID<n>-CPU(W) [PID<n>-CPU(J)] PID<n>-GPU(W) [PID<n>-GPU(J)] ...
    

    Per-pid GPU values are derived from nvmlDeviceGetProcessUtilization SM samples and are proportional to the total GPU power/energy across all NVIDIA devices.

  • Self-overhead (-f o): Three columns are appended after the per-process columns, and a one-line summary is printed to stderr at exit:

    ... OBS-CPU(ms/s) OBS-WAKE(/s) OBS-RAPLRD(/s)
    
    • OBS-CPU(ms/s): CPU time used by power_eye itself (all threads) per second.
    • OBS-WAKE(/s): how often power_eye was put on a CPU per second (from schedstat).
    • OBS-RAPLRD(/s): RAPL energy_uj reads per second. Each read runs an MSR read on a CPU of that domain's package and, unless power_eye happens to run there, wakes that CPU by IPI, so this is an upper bound on the wakeups caused on other CPUs (DRAM domains with -d add reads). With -B it counts the samples power_eye forced itself, normally 0 on a busy system.

    OBS-CPU and OBS-WAKE need CONFIG_SCHED_INFO; without it they show -. This reports what power_eye itself did; it does not measure the system-wide effect (extra idle exits, reduced package C-state residency).

  • Adaptive interval (-A): One column, INT(s), is appended after all other columns (after the self-overhead columns, if any). Averaging over a long interval hides short bursts: a burst raises the average only by burst energy / interval, so with a long cap only sustained changes are noticed. The interval is changed at the end of a tick; timestamps and (J) columns use the interval of that row. Per-GPU process utilization (-f g) still assumes the interval it was started with and is not adjusted.

  • Coma detection (-C): Time is cut into windows (-W, default 10 minutes). A window is idle if its mean package power is within -D of the idle floor and its package C6 residency is at least -R. After <hours> of consecutive idle windows the node is a coma candidate; a busy window ends it. Output goes to stdout as # lines after the data row that closed the window, and a summary to stderr at exit:

    # window 10-04 10:00:00 .. 10-04 10:10:00 25.412 W (floor 25.301 W, +0.111 W) deep 86.3% -> idle (idle for 1.00 h)
    # COMA CANDIDATE: idle since 10-04 09:10:00 (1.00 h)
    # coma candidacy ended: busy window ending 10-04 12:30:00
    

    With -A, the interval is cut so that ticks end on window boundaries, and besides power the deep residency now also resets the interval to -i when it moves by more than 10 percentage points. The verdict is made at a window end, so it comes at most one window after the idle time reaches <hours>. Without -B (or without a cstate_pkg PMU) there is no residency and the verdict uses power only, which is unreliable; a warning says so. A short burst inside a window is averaged away, as with -A. Limitation: if the node has small periodic activity (e.g. 1-1.5 W every minute or so), changes larger than the -T band keep resetting the interval to -i, so it may take a long time to reach the cap. In a 90 minute server run the interval first reached 600 s after about 1 hour; the coma verdict itself was unaffected (see results/coma-long/summary.md). A wider -T reduces this at the cost of reacting less to real changes. Example:

    sudo power_eye -B -d -i 1 -A 600 -C 6 -t 100000000 -f cEH

Examples

  • CPU power, with energy and header, sampled every 1s for 30s:

    power_eye -t 30 -f cEH
  • CPU + DRAM + GPU per-device, with energy and header:

    power_eye -d -t 60 -f cGEH
  • Per-process CPU/GPU attribution for two pids:

    power_eye -p 1234 -p 5678 -t 60 -f cgEH
  • Observation cost: add o (CPU time, wakeups and RAPL reads of power_eye itself):

    sudo power_eye -d -t 60 -f cEHo
  • eBPF sampler (no IPI for RAPL reads; needs a USE_BPF=ON build):

    sudo power_eye -B -d -i 1 -t 60 -f cEHo
  • Adaptive interval, 1 s base up to 10 minutes:

    sudo power_eye -B -d -i 1 -A 600 -t 3600 -f cEHo
  • Long-idle detection: a coma candidate after 0.5 h of idle 10-minute windows, idle floor 25 W:

    sudo power_eye -B -d -i 1 -A 600 -C 0.5 -F 25.0 -t 5400 -f cEHo

Observer effect and benchmarks

A monitor is itself a load: every sample wakes a CPU, and a sysfs energy_uj read also wakes a CPU of each package by IPI. On the test server (2x Xeon E5-2650 v4, package C6 enabled) one sample cost about 15 mJ, below detection at 1 Hz and visible at 100 Hz. -B removes the remote wakeups and -A reduces the own wakeups when the system is idle.

  • tools/bench: A/B harness with a non-perturbing reference measurement (counters read only at the window start and end), paired statistics, dose-response regression, a five-condition runner (run_conditions.sh) and raw CSV export. See tools/bench/README.md.
  • tools/report: plot_report.py draws the three report figures (observer cost per condition, adaptive interval with coma detection, extra power against sample rate) from the committed results. Run python3 tools/report/plot_report.py from the repository root (needs matplotlib); it writes PNG and SVG plus the plotted numbers as CSV to results/report/. Options: --out, --format png,svg, --root. The figures have no titles or captions.
  • tools/bpf-feasibility, tools/bpf-prototype: probes and the standalone idle-exit sampler that -B is based on.
  • results/coma-long: a 90 minute run with -A and -C, and results/compiled: the data compiled from the experiments so far (env.txt explains where each row comes from; adaptive and node_exporter are not yet measured under the same conditions as the others).

License

This project is licensed under the MIT License. See the LICENSE file for details.

Notes

  • Platform support

    • Requires Linux with RAPL exposed under /sys/class/powercap.
    • Works on Intel CPUs that support RAPL. AMD/others are not supported.
    • All CPU packages (intel-rapl:N) are read and summed; DRAM subdomains are summed the same way. Per-socket breakdown is not available.
    • RAPL counter wraparound is handled using max_energy_range_uj.
    • The DRAM RAPL domain may not be present on all platforms.
  • Permissions

    • Reading energy_uj may require elevated privileges. Use sudo or adjust permissions via a udev rule (distro-specific).
    • -B needs root (perf events and BPF) and a kernel that exposes the power PMU; tested on Ubuntu with kernel 6.8. Package C6 residency (-C) needs the cstate_pkg PMU. If package C-states are disabled in the BIOS, residency is 0 and -C never reports idle.
  • eBPF sampler (-B) and coma detection (-C)

    • Verified on a dual-socket Xeon E5-2650 v4 only. At sample rates of 20 Hz and above -B forces samples itself and behaves like sysfs.
    • Short bursts are averaged away in long intervals; residency uses package C6 only.
  • DRAM flag (-d)

    • If your system lacks a DRAM RAPL domain, a warning is printed and DRAM output is disabled; the run continues with CPU only.
  • GPU measurement (-f g, -f G)

    • Requires NVIDIA driver + NVML (libnvidia-ml.so) and a build with -DUSE_NVML=ON.
    • -f G includes per-GPU metrics and implies -f g.
    • If NVML isn't available or no NVIDIA GPUs are present, GPU measurement will not work.
  • Per-process measurement (-p <pid>)

    • CPU energy per pid is proportional to the pid's CPU time delta over the interval (from /proc/<pid>/stat).
    • GPU energy per pid is proportional to its average smUtil from nvmlDeviceGetProcessUtilization. On multi-GPU systems, each device's contribution is weighted by that device's current power so a pid using only one GPU is not credited for power drawn by idle GPUs.
    • The pid must be visible to the user running power_eye. NVML process utilization may require the same user/permissions as the GPU process.
  • Timing & alignment

    • Using absolute time scheduling, sampling is aligned to second-of-minute boundaries, keeping timing consistent across runs.
  • Units & fields

    • Power is in watts (W) and energy in joules (J).
    • Use -f E to include energy columns; -f H prints a header row; -f d adds MM-DD to the timestamp.
  • Accuracy considerations

    • CPU energy uses RAPL counters (platform-estimated). GPU energy is trapezoid-integrated from instantaneous NVML power readings.
    • Shorter intervals generally improve integration accuracy but increase overhead.
  • Containers/VMs

    • Some containers or virtual machines do not expose /sys/class/powercap or NVML; measurements may be unavailable there.
  • More info