1 change: 1 addition & 0 deletions .changelog/5724.added
Original file line number Diff line number Diff line change
@@ -0,0 +1 @@
`opentelemetry-sdk`: make `Logger.enabled()` respect the configured minimum severity and trace-based filtering
Original file line number Diff line number Diff line change
Expand Up @@ -5,6 +5,7 @@

import logging

from opentelemetry._logs import SeverityNumber as SDKSeverityNumber
from opentelemetry._logs import set_logger_provider
from opentelemetry.configuration._common import (
_map_compression,
Expand Down Expand Up @@ -239,24 +240,19 @@ def _create_log_record_processor(
def _to_logger_config(config: LoggerConfigConfig | None) -> _LoggerConfig:
"""Map an experimental per-logger config to an SDK ``_LoggerConfig``.

Only ``enabled`` is honored. ``minimum_severity`` and ``trace_based`` are
accepted by the config schema but not supported by the Python SDK
``_LoggerConfig``; the ones that are set are ignored with a warning naming
them. An absent ``enabled`` leaves the logger enabled.
Absent fields use the defaults defined by the Logs SDK specification.
"""
if config is None:
return _LoggerConfig.default()
unsupported_fields = [
field_name for field_name in ("minimum_severity", "trace_based") if getattr(config, field_name) is not None
]
if unsupported_fields:
_logger.warning(
"Ignoring logger_configurator fields that are not supported by the Python SDK LoggerProvider: %s",
", ".join(unsupported_fields),
)
if config.enabled is None:
return _LoggerConfig.default()
return _LoggerConfig(is_enabled=config.enabled)
return _LoggerConfig(
is_enabled=config.enabled if config.enabled is not None else True,
minimum_severity=(
SDKSeverityNumber[config.minimum_severity.name.upper()]
if config.minimum_severity is not None
else SDKSeverityNumber.UNSPECIFIED
),
trace_based=config.trace_based if config.trace_based is not None else False,
)


def _create_logger_configurator(
Expand Down
38 changes: 11 additions & 27 deletions opentelemetry-configuration/tests/test_logger_provider.py
Original file line number Diff line number Diff line change
Expand Up @@ -9,6 +9,7 @@
import unittest
from unittest.mock import MagicMock, patch

from opentelemetry._logs import SeverityNumber as SDKSeverityNumber
from opentelemetry._logs import get_logger_provider
from opentelemetry.configuration._logger_provider import (
_DEFAULT_EXPORT_TIMEOUT_MILLIS,
Expand Down Expand Up @@ -608,7 +609,7 @@ def test_absent_enabled_defaults_to_enabled(self):
provider = create_logger_provider(config)
self.assertTrue(self._enabled(provider, "any.scope"))

def test_unsupported_minimum_severity_logs_warning(self):
def test_minimum_severity_is_applied(self):
config = LoggerProviderConfig(
processors=[],
logger_configurator_development=LoggerConfiguratorConfig(
Expand All @@ -618,21 +619,14 @@ def test_unsupported_minimum_severity_logs_warning(self):
),
),
)
with self.assertLogs(
"opentelemetry.configuration._logger_provider",
level="WARNING",
) as cm:
create_logger_provider(config)
self.assertTrue(
any("minimum_severity" in msg for msg in cm.output),
"Expected warning about unsupported minimum_severity",
)
self.assertFalse(
any("trace_based" in msg for msg in cm.output),
"Warning must not name trace_based when it is not set",
provider = create_logger_provider(config)

self.assertEqual(
provider._apply_logger_configurator(InstrumentationScope("any.scope")).minimum_severity,
SDKSeverityNumber.WARN,
)

def test_unsupported_trace_based_logs_warning(self):
def test_trace_based_is_applied(self):
config = LoggerProviderConfig(
processors=[],
logger_configurator_development=LoggerConfiguratorConfig(
Expand All @@ -642,19 +636,9 @@ def test_unsupported_trace_based_logs_warning(self):
),
),
)
with self.assertLogs(
"opentelemetry.configuration._logger_provider",
level="WARNING",
) as cm:
create_logger_provider(config)
self.assertTrue(
any("trace_based" in msg for msg in cm.output),
"Expected warning about unsupported trace_based",
)
self.assertFalse(
any("minimum_severity" in msg for msg in cm.output),
"Warning must not name minimum_severity when it is not set",
)
provider = create_logger_provider(config)

self.assertTrue(provider._apply_logger_configurator(InstrumentationScope("any.scope")).trace_based)


if __name__ == "__main__":
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -78,6 +78,7 @@
from opentelemetry.trace import (
format_span_id,
format_trace_id,
get_current_span,
)
from opentelemetry.util.types import AnyValue, Attributes

Expand Down Expand Up @@ -728,6 +729,8 @@ def flush(self) -> None:
@dataclass
class _LoggerConfig:
is_enabled: bool = True
minimum_severity: SeverityNumber = SeverityNumber.UNSPECIFIED
trace_based: bool = False

@classmethod
def default(cls) -> _LoggerConfig:
Expand Down Expand Up @@ -770,6 +773,16 @@ def enabled(
) -> bool:
if not self._is_enabled():
return False
if (
severity_number is not None
and severity_number is not SeverityNumber.UNSPECIFIED
and severity_number.value < self._logger_config.minimum_severity.value
):
return False
if self._logger_config.trace_based:
span_context = get_current_span(context).get_span_context()
if span_context.is_valid and not span_context.trace_flags.sampled:
return False
return self._multi_log_record_processor.enabled(
context=context,
instrumentation_scope=self._instrumentation_scope,
Expand Down
70 changes: 70 additions & 0 deletions opentelemetry-sdk/tests/logs/test_logs.py
Original file line number Diff line number Diff line change
Expand Up @@ -38,6 +38,12 @@
_scope_name_matches_glob,
)
from opentelemetry.semconv.attributes import exception_attributes
from opentelemetry.trace import (
NonRecordingSpan,
SpanContext,
TraceFlags,
set_span_in_context,
)


class TestLoggerProvider(unittest.TestCase):
Expand Down Expand Up @@ -503,6 +509,70 @@ def test_enabled_disabled_logger_returns_false(self):
logger = provider.get_logger("test")
self.assertFalse(logger.enabled())

def test_enabled_below_minimum_severity_returns_false(self):
logger, processor = self._get_logger()
logger._set_logger_config(_LoggerConfig(minimum_severity=SeverityNumber.WARN))

self.assertFalse(logger.enabled(severity_number=SeverityNumber.INFO4))
processor.enabled.assert_not_called()

def test_enabled_at_or_above_minimum_severity_returns_true(self):
logger, processor = self._get_logger()
logger._set_logger_config(_LoggerConfig(minimum_severity=SeverityNumber.WARN))
processor.enabled.return_value = True

self.assertTrue(logger.enabled(severity_number=SeverityNumber.WARN))
self.assertTrue(logger.enabled(severity_number=SeverityNumber.ERROR))

def test_enabled_unspecified_severity_bypasses_minimum_severity(self):
logger, processor = self._get_logger()
logger._set_logger_config(_LoggerConfig(minimum_severity=SeverityNumber.WARN))
processor.enabled.return_value = True

self.assertTrue(logger.enabled())
self.assertTrue(logger.enabled(severity_number=SeverityNumber.UNSPECIFIED))

def test_enabled_trace_based_unsampled_trace_returns_false(self):
logger, processor = self._get_logger()
logger._set_logger_config(_LoggerConfig(trace_based=True))
context = set_span_in_context(
NonRecordingSpan(
SpanContext(
trace_id=1,
span_id=1,
is_remote=False,
trace_flags=TraceFlags.get_default(),
)
)
)

self.assertFalse(logger.enabled(context=context))
processor.enabled.assert_not_called()

def test_enabled_trace_based_sampled_trace_returns_true(self):
logger, processor = self._get_logger()
logger._set_logger_config(_LoggerConfig(trace_based=True))
processor.enabled.return_value = True
context = set_span_in_context(
NonRecordingSpan(
SpanContext(
trace_id=1,
span_id=1,
is_remote=False,
trace_flags=TraceFlags(TraceFlags.SAMPLED),
)
)
)

self.assertTrue(logger.enabled(context=context))

def test_enabled_trace_based_without_trace_returns_true(self):
logger, processor = self._get_logger()
logger._set_logger_config(_LoggerConfig(trace_based=True))
processor.enabled.return_value = True

self.assertTrue(logger.enabled(context=get_current()))

def test_enabled_passes_args_to_processor(self): # pylint: disable=no-self-use
provider = LoggerProvider()
processor_mock = Mock()
Expand Down