modbusctl 3.1.0: record and replay every spec read function; capture commands replace mcap - #2

Merged
boeboe merged 7 commits into
mainfrom
feat/serve-all-functions
Oct 15, 2026
Merged

boeboe merged 7 commits into
mainfrom
feat/serve-all-functions

Conversation

@boeboe

@boeboe boeboe commented Oct 15, 2026 •

Copy link
Copy Markdown
Contributor

Summary

modbusctl 3.1.0: record and replay every read function of the Modbus specification on go-modbus v1.7.1 and go-modbus-capture (MBCAP). Vendor and unknown function codes are not supported anywhere. The mcap command group becomes capture, and MCAP v1 references are removed.

Dependencies: go-modbus v1.7.1 (v1.7.1 removes RawRequestHandler, which this PR does not use) and go-modbus-capture v0.0.2. Its capture.CheckPDUs accepts only the spec read functions in every reader and writer; capfile.IsSpecRead builds on capture.IsReadFunction with the same FC08/FC43 rules. A file the library rejects for a sample's function code is still reported as capture_unsupported_function (exit 3), not as a corrupt file.

Record and replay

  • client record takes a plan (--blocks-file). Entries with function may use FC01–04, FC07, FC08 (data-returning sub-functions 0x00, 0x02, 0x0B–0x12), FC11, FC12, FC17, FC20, FC24 or FC43/14. Plain address blocks work as before. Anything else is refused before it is sent (internal/plan). Each request uses the retry loop of reads.
  • server static / server replay serve FC08, FC17, FC20 and FC24 through go-modbus v1.7.1's typed handlers, alongside FC01–04, FC07, FC11, FC12 and FC43. No RawRequestHandler: go-modbus answers every other function code, vendor and unknown ones included, with Illegal Function.
  • Loading rejects a capture holding a non-spec sample (capture_unsupported_function, exit 3), and the recorder never writes one.
  • --listen on both servers (default: every interface). The "🚀 Serving" line is printed once the listener is bound.

MCAP v1 removal

  • Commands: modbusctl mcap … → modbusctl capture … (decode, extract, strings, frequencies). info, verify and convert are removed because they duplicate mbcapctl; the README points to it. internal/mcap → internal/analysis.
  • JSON and error codes: mcap_output_path → capture_output_path; mcap_load_failed / mcap_write_failed → capture_load_failed / capture_write_failed.
  • Files: Docker volume /captures; docker-compose.yml, Makefile and .gitignore name .mbcap. ALGOS, CONTRIBUTING, SECURITY and docs updated. The README says once that 2.x .mcap files are not read.
  • Docs: the README links go-modbus-capture's FORMAT.md and mbcapctl instead of repeating them, and documents the plan format. RELEASE.md has a v3.1.0 entry with the CLI renames listed as breaking.

The intermittent internal/modbus failure

Root cause: a port race in the test helpers. They bound 127.0.0.1:0, closed it, and started the server on 0.0.0.0:N. Under load another test's socket took N in between. Then either the bind failed (address already in use), or, on macOS, the wildcard bind succeeded next to another test's 127.0.0.1:N listener: the readiness probe connected to that listener and the test client talked to the wrong device (unexpected EOF).

Evidence: -race -count=50 -cpu 1,2,8 on the old code under load gave 4 failures, all this race (two address already in use, two unexpected EOF).

Fix:

  • Test servers listen on 127.0.0.1 exactly (--listen).
  • Readiness is the server's own "Serving" line after the bind, not a probe connection.
  • Only a bind that fails with EADDRINUSE moves to another port.
  • TestCollServer_portTakenOnLoopback pins this down.

Tests

  • TestRoundTrip_everyFunction: record → file → replay for every supported function. Sources: a go-modbus v1.7.1 server, and mbtest over tcp, rtuovertcp and udp. Each file passes mbcapctl verify; static and replay servers answer byte for byte.
  • TestRoundTrip_textEncodings: mbcapctl convert to .mbcap.jsonl and .mbcap.csv serves the same.
  • TestChaosRoundTrip_everyFunction: busy, dropped, closed, truncated and late answers over tcp and rtuovertcp. Only valid answers the device actually sent are recorded.
  • TestParallelRoundTrip_everyFunction: four devices recorded at once, then 8 clients per recording against static and replay servers.
  • mbtest: RTU framing for every spec read function.
  • tcp+tls: not covered, because modbusctl's client has no TLS certificate settings (tcp+tls is not usable from the CLI today).
  • Checks: make check passes (fmt, staticcheck, golangci-lint 0 issues, vet, -race tests, coverage 96.4%).

🤖 Generated with Claude Code

boeboe and others added 2 commits October 15, 2026 02:10
go-modbus v1.7.0 dispatches every function code and hands the ones a
handler does not decode to an optional RawRequestHandler. The capture
handler implements it: FC07, FC08, FC0B, FC0C, FC11, FC12, FC17, FC20,
FC24, other FC43 MEI types and vendor functions are answered with the
response recorded for exactly that request PDU, byte for byte. The
typed FC07/0B/0C handlers go, as the raw path covers them. FC21, FC22
and FC23 writes are refused with Illegal Function.

E2E tests record FC08, FC17, FC20 and FC24 from a go-modbus server and
check the static and replay servers answer them byte for byte.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
@codecov

codecov Bot commented Oct 15, 2026 •

Copy link
Copy Markdown

Per the owner, vendor and unknown function codes are not supported.
Drop the RawRequestHandler and serve FC08 (data-returning
sub-functions 0x00, 0x02, 0x0B-0x12), FC17, FC20 and FC24 through
go-modbus v1.7.0's DiagnosticsHandler, ReportServerIDHandler,
ReadFileRecordHandler and FIFOQueueHandler, with the data taken from
the recorded response PDU. FC07/0B/0C/43 keep their typed handlers.
go-modbus answers every other function code with Illegal Function.

capfile.IsSpecRead defines the supported reads. Load rejects a capture
holding any other sample (capture_unsupported_function, exit 3), and
the recorder refuses to write one. Tests cover refusal on load and in
the recorder, Illegal Function for vendor, unknown, FC43/0D, FC08
state-changing and FC21-23 requests on a live server, and vendor
--function values in read, scan and record.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
@boeboe boeboe changed the title Serve every recorded function on the static and replay servers (go-modbus v1.7.0) Serve FC08, FC17, FC20 and FC24 from captures; refuse vendor and unknown functions (go-modbus v1.7.0) Oct 15, 2026
boeboe and others added 2 commits October 15, 2026 03:03
Port race (the internal/modbus failure seen once): test helpers picked
a port by binding 127.0.0.1:0 and closing it, and the server then bound
0.0.0.0:N. Under load another test's socket took N in between: either
EADDRINUSE, or on macOS the wildcard bind succeeded next to another
test's 127.0.0.1:N listener, the probe connected to that listener and
the test client talked to the wrong device (unexpected EOF). The
servers get --listen; they report "Serving" only after the listener is
bound; test helpers bind 127.0.0.1 exactly, wait for that report and
move to another port only on EADDRINUSE.

Recording: the --blocks-file plan (internal/plan) may name any read
function of the specification: FC01-04 blocks as before, FC07, FC08
data-returning sub-functions, FC11, FC12, FC17, FC20, FC24 and FC43/14.
Anything else is refused before it is sent. client record sends each
entry with the retry loop of reads (exchange).

Tests: record -> file -> replay round trips for every function from a
go-modbus server and mbtest devices over tcp, rtuovertcp and udp, with
mbcapctl verify and convert; chaos (busy, drop, close, truncated,
late) and parallel variants. mbtest frames every spec read over RTU.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- `modbusctl mcap` becomes `modbusctl capture` (decode, extract,
  strings, frequencies). info, verify and convert are removed: they
  duplicate mbcapctl of go-modbus-capture, which the docs point to.
  internal/mcap becomes internal/analysis.
- JSON summaries say capture_output_path; error codes
  capture_load_failed and capture_write_failed.
- Docker volume /captures; compose, Makefile and .gitignore name .mbcap.
- README: capture files section links go-modbus-capture (FORMAT.md,
  mbcapctl) instead of repeating it; the plan file format of client
  record; --listen. RELEASE.md: 3.1.0 with the CLI renames as breaking.
- client record examples gave intervals in seconds; they are ms.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
@boeboe boeboe changed the title Serve FC08, FC17, FC20 and FC24 from captures; refuse vendor and unknown functions (go-modbus v1.7.0) modbusctl 3.1.0: record and replay every spec read function; capture commands replace mcap Oct 15, 2026
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
v0.0.2's readers and writers accept only the read functions of the
specification (capture.CheckPDUs). IsSpecRead now builds on
capture.IsReadFunction with the same FC08 and FC43 rules. A load that
the library rejects for a sample's function code is still reported as
ErrUnsupportedFunction (capture_unsupported_function, exit 3) rather
than a corrupt file. The test for it writes the bad samples as JSON
Lines by hand, since the writers no longer produce them.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
@boeboe
boeboe merged commit b821bfb into main Oct 15, 2026
6 checks passed