Skip to content
Merged
Show file tree
Hide file tree
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
38 changes: 38 additions & 0 deletions CHANGELOG.md
Original file line number Diff line number Diff line change
Expand Up @@ -2,6 +2,44 @@

## [Unreleased]

### alphaess 1.3.0, kstar 1.3.0

Both drivers read the registers their vendor's own Modbus map gives
(srcfl/device-drivers#257). Earlier releases read addresses no source
supports, so their PV, battery and meter values were probably wrong. Each
stream now goes out only when its read answered, never as zeros. Written
from the sources in each manifest's `upstream_docs`. Not yet checked on
hardware.

- **alphaess 1.3.0** follows AlphaESS's parameter address table. Grid meter:
total power at 0x0021 (S32, positive when drawing from the grid), phase A
current at 0x0017, frequency at 0x001A. Battery: power at 0x0126, which
AlphaESS counts positive when discharging, so the driver negates it;
voltage at 0x0100 and SoC at 0x0102 (0.1 %). PV: the sum of the six string
powers at 0x041F-0x0433, with string 1 voltage and current. Earlier
releases read meter energy counters and voltages at 0x0010-0x0028 as PV,
battery and meter values. The grid phase voltage is no longer sent: the
sources disagree on its scale. 0x0111/0x0112 are still not used as live
BMS limits. The meter and PV strings 4 to 6 are read only once 0x074E
(Protocol Version, in the System info block V1.20 added) answers; firmware
on the 2020 map (V1.17, meter at 0x0000-0x0019) gets PV strings 1 to 3
and no meter.
- **kstar 1.3.0** reads KSTAR's input registers (function 04H) from 3000, as
KSTAR's Hybrid Inverter Modbus V2.9.1 gives them for the KSE, BluE-S and
E-series three-phase models: PV at 3000-3025, battery voltage, power and
SoC at 3063-3066 (beside the temperatures it already read) and the grid
meter at 3097-3108. KSTAR gives no signs; following ha-solarman, the
meter power (positive when exporting) and the battery power (positive
when discharging) are negated. The model at 3045 says whether the S and
T phases exist; a code KSTAR's model table does not name sends no meter.
Earlier releases read holding registers 10-54, which no source has.

In both drivers, battery voltage and SoC both 0 means no pack is connected,
so the battery stream is left out rather than sent as an empty pack.
Neither vendor map has a flag that says a grid meter is fitted, so with no
meter both drivers send whatever the meter registers hold: 0 W there cannot
be told from a balanced site.

### fronius 2.3.0

Battery power, voltage and SoC now come from the registers Fronius's GEN24
Expand Down
8 changes: 4 additions & 4 deletions SUPPORT_STATUS.md
Original file line number Diff line number Diff line change
Expand Up @@ -20,8 +20,8 @@ Catalog source is not proof that a target can install or run a driver.
| acuvim | 0.4.3 | blixt-l1 | not_assessed | — | not_recorded | not_assessed |
| alfen | 1.1.1 | ftw-core | not_assessed | — | not_recorded | not_assessed |
| alfen | 1.1.1 | blixt-l1 | not_assessed | — | not_recorded | not_assessed |
| alphaess | 1.2.0 | ftw-core | not_assessed | — | not_recorded | not_assessed |
| alphaess | 1.2.0 | blixt-l1 | not_assessed | — | not_recorded | not_assessed |
| alphaess | 1.3.0 | ftw-core | not_assessed | — | not_recorded | not_assessed |
| alphaess | 1.3.0 | blixt-l1 | not_assessed | — | not_recorded | not_assessed |
| ambibox | 1.2.0 | ftw-core | not_assessed | — | not_recorded | not_assessed |
| ambibox | 1.2.0 | blixt-l1 | not_assessed | — | not_recorded | not_assessed |
| ambibox_v2x | 1.1.1 | ftw-core | not_assessed | — | not_recorded | not_assessed |
Expand Down Expand Up @@ -90,8 +90,8 @@ Catalog source is not proof that a target can install or run a driver.
| konja-261-svk | 0.4.0 | blixt-l1 | not_assessed | — | not_recorded | not_assessed |
| kostal | 2.2.0 | ftw-core | not_assessed | — | not_recorded | not_assessed |
| kostal | 2.2.0 | blixt-l1 | not_assessed | — | not_recorded | not_assessed |
| kstar | 1.2.0 | ftw-core | not_assessed | — | not_recorded | not_assessed |
| kstar | 1.2.0 | blixt-l1 | not_assessed | — | not_recorded | not_assessed |
| kstar | 1.3.0 | ftw-core | not_assessed | — | not_recorded | not_assessed |
| kstar | 1.3.0 | blixt-l1 | not_assessed | — | not_recorded | not_assessed |
| mennekes | 1.1.1 | ftw-core | not_assessed | — | not_recorded | not_assessed |
| mennekes | 1.1.1 | blixt-l1 | not_assessed | — | not_recorded | not_assessed |
| myuplink | 1.2.4 | ftw-core | not_assessed | — | not_recorded | not_assessed |
Expand Down
8 changes: 4 additions & 4 deletions devices.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -135,7 +135,7 @@ manufacturers:
protocols:
- protocol: modbus
driver: "alphaess"
version: "1.2.0"
version: "1.3.0"
ders: [pv, battery, meter]
control: false
firmware_versions: ""
Expand All @@ -146,7 +146,7 @@ manufacturers:
protocols:
- protocol: modbus
driver: "alphaess"
version: "1.2.0"
version: "1.3.0"
ders: [pv, battery, meter]
control: false
firmware_versions: ""
Expand Down Expand Up @@ -761,7 +761,7 @@ manufacturers:
protocols:
- protocol: modbus
driver: "kstar"
version: "1.2.0"
version: "1.3.0"
ders: [pv, battery, meter]
control: false
firmware_versions: ""
Expand All @@ -772,7 +772,7 @@ manufacturers:
protocols:
- protocol: modbus
driver: "kstar"
version: "1.2.0"
version: "1.3.0"
ders: [pv, battery, meter]
control: false
firmware_versions: ""
Expand Down
Loading