Original file line number Diff line number Diff line change
Expand Up @@ -2,6 +2,29 @@

## [Unreleased]

### growatt 2.2.2

A failed read no longer becomes 0 (docs/WRITING-A-DRIVER.md, "Never
fabricate"). Up to 2.2.1 every PV, battery and meter value started at 0, so a
read that did not answer sent 0 W, 0 V or 0 % SoC. A 0 W meter looks like a
site in balance, a 0 % SoC like an empty pack.

- Each field comes only from a read that answered with every register asked
for; metrics likewise.
- PV goes out only when its power (1-2) answers, and the meter only when its
power (1015-1016) answers. So a failed power read also drops that
stream's energy counter and its MPPT or phase values for that poll; the
phase values still reach history as metrics.
- The battery follows "A hybrid inverter may have no battery": each field
only from a read that answered, and the stream when what answered shows a
battery. Its power needs both 1009 and 1011, since either alone is not the
net.

This is the never-fabricate half of srcfl/device-drivers#263. Which
registers the meter should read is srcfl/device-drivers#271 and is not
changed here. growatt leaves `drivers/tests/invented-number-baseline.json`.
Not yet checked on hardware.

### victron 2.2.1, ferroamp_modbus 2.2.1

A failed read no longer sends 0 on the meter and PV streams
Expand Down
4 changes: 2 additions & 2 deletions SUPPORT_STATUS.md
Original file line number Diff line number Diff line change
Expand Up @@ -70,8 +70,8 @@ Catalog source is not proof that a target can install or run a driver.
| goe_http | 1.1.0 | blixt-l1 | not_assessed | — | not_recorded | not_assessed |
| goodwe | 2.2.0 | ftw-core | not_assessed | — | not_recorded | not_assessed |
| goodwe | 2.2.0 | blixt-l1 | not_assessed | — | not_recorded | not_assessed |
| growatt | 2.2.1 | ftw-core | not_assessed | — | not_recorded | not_assessed |
| growatt | 2.2.1 | blixt-l1 | not_assessed | — | not_recorded | not_assessed |
| growatt | 2.2.2 | ftw-core | not_assessed | — | not_recorded | not_assessed |
| growatt | 2.2.2 | blixt-l1 | not_assessed | — | not_recorded | not_assessed |
| hardybarth | 1.1.1 | ftw-core | not_assessed | — | not_recorded | not_assessed |
| hardybarth | 1.1.1 | blixt-l1 | not_assessed | — | not_recorded | not_assessed |
| heishamon | 0.8.1 | ftw-core | not_assessed | — | not_recorded | not_assessed |
Expand Down
12 changes: 6 additions & 6 deletions devices.yaml
Original file line number Diff line number Diff line change
Expand Up @@ -522,7 +522,7 @@ manufacturers:
protocols:
- protocol: modbus
driver: "growatt"
version: "2.2.1"
version: "2.2.2"
ders: [pv, battery, meter]
control: false
firmware_versions: ""
Expand All @@ -533,7 +533,7 @@ manufacturers:
protocols:
- protocol: modbus
driver: "growatt"
version: "2.2.1"
version: "2.2.2"
ders: [pv, battery, meter]
control: false
firmware_versions: ""
Expand All @@ -544,7 +544,7 @@ manufacturers:
protocols:
- protocol: modbus
driver: "growatt"
version: "2.2.1"
version: "2.2.2"
ders: [pv, battery, meter]
control: false
firmware_versions: ""
Expand All @@ -555,7 +555,7 @@ manufacturers:
protocols:
- protocol: modbus
driver: "growatt"
version: "2.2.1"
version: "2.2.2"
ders: [pv, battery, meter]
control: false
firmware_versions: ""
Expand All @@ -566,7 +566,7 @@ manufacturers:
protocols:
- protocol: modbus
driver: "growatt"
version: "2.2.1"
version: "2.2.2"
ders: [pv, battery, meter]
control: false
firmware_versions: ""
Expand All @@ -577,7 +577,7 @@ manufacturers:
protocols:
- protocol: modbus
driver: "growatt"
version: "2.2.1"
version: "2.2.2"
ders: [pv, battery, meter]
control: false
firmware_versions: ""
Expand Down