Easee startup delayed ~11 minutes with zero pilot despite accepted current limits and available site headroom #1948

Closed

Description

@segran2

Problem

On real equipment, an Easee Cloud charger acknowledged repeated resume commands and a positive dynamic current limit, but its reported effective pilot remained 0 A and measured EV power remained 0 W for approximately 11 minutes. Pixii was charging concurrently, so the allocation was reviewed rather than assuming the battery blocked the car.

Please investigate the gap between accepted dynamic-current/resume commands and the effective pilot, and whether FTW's feedback/start retry handling correctly explains this condition.

Related: #1874 (effective pilot versus dynamic current setting), #1761 (site headroom during battery charging). This incident adds a prolonged zero-pilot startup on v0.157.3 and a measured allocation timeline.

Environment

  • FTW Core: v0.157.3-beta.1+local.1; recorded build revision 1b0972e157ff4fd675df370809ae2414cc6ffc62.
  • Easee Cloud charger, three-phase loadpoint, Pixii battery and site meter.
  • Configured fuse: 25 A per phase, 0.5 A safety margin (24.5 A working limit).
  • EV maximum: 10,350 W; minimum: 4,140 W; configured 230 V.
  • Saved loadpoint binding matches the running Easee driver; OCPP disabled.
  • Incident: 1 November 2026, Europe/Stockholm (CET, UTC+1).
  • Read-only investigation; no dispatch, priority or fuse settings changed.

Startup timeline

  • 04:30:49: resume acknowledged, offer 8,970 W (13 A/phase), observed power 0 W.
  • 04:31:19: second resume acknowledged, same offer and 0 W.
  • 04:31:54: third resume acknowledged, same offer and 0 W.
  • 04:32:29: log: loadpoint resume acknowledged but no charge observed.
  • Stored Easee series show the dynamic current setting at 13 A, later 15 A from approximately 04:34. Effective pilot remains 0 A.
  • First nonzero pilot/power bucket appears around 04:41:49; approximately 6.8 kW follows around 04:42.
  • A similar sequence recurs at 05:19:49 / 05:20:19 / 05:20:54, followed by the same warning at 05:21:24.

The UI was reported as “Not following” during the incident. The exact historical feedback reason object was not retained, so it should not be assumed to have been a particular reason code.

Later start delay and corrected interpretation of 06:24

Further review found the following retries on 1 November 2026, CET (UTC+1):

Resume acknowledgement Attempt Offered power Observed power
05:45:49 1 10,350 W 0 W
05:46:24 2 10,350 W 0 W
05:46:59 3 10,350 W 0 W

At 05:47:34, Core logged loadpoint resume acknowledged but no charge observed. The pilot stayed at 0 A until approximately 05:56, after which measured charging reached approximately 5.44 kW. The 05:19 sequence similarly began drawing approximately 4.8 kW around 05:29, before the dynamic setting dropped to 0 A around 05:30, consistent with a scheduled pause.

There are therefore three unexplained delayed-start sequences: approximately 04:30, 05:19 and 05:45.

Correction: the vehicle had reached its 80% charge limit at 06:24

The owner confirms that the vehicle was already charged to its own 80% limit at 06:24. This is owner-supplied context, not a fresh SoC observation independently verified by FTW.

The logs still record resume acknowledgements at 06:23:54, 06:24:29 and 06:24:59 (7,590 W offered, 0 W observed), followed by loadpoint resume acknowledged but no charge observed at 06:25:29. However, stored telemetry shows a positive effective pilot of approximately 9 A after the restart, with nearly zero measured draw.

Do not count this as a fourth unexplained zero-pilot startup failure. The lack of draw is explained by the vehicle reaching its charge limit. The separate question is why Core continued restart attempts and emitted a generic no-charge warning after charging had completed, and how completion should be represented when fresh vehicle SoC/charge-limit evidence is unavailable. Do not suppress genuine failures solely on an assumed charge limit.

Concurrent battery allocation

The following are nearby stored measurement samples, rounded for readability. Samples from different series are not perfectly simultaneous.

Local time Pixii charging Highest measured site phase Easee dynamic limit Effective pilot EV power
04:29:30 8.82 kW 23.89 A 0 A 0 A 0 kW
04:31:30 ~0 kW 11.41 A 13 A 0 A 0 kW
04:35:30 1.25 kW 5.59 A 15 A 0 A 0 kW
04:40:30 4.69 kW 9.65 A 15 A 0 A 0 kW
04:42:30 ~0 kW 13.34 A 15 A 10 A 6.80 kW
04:44:30 3.74 kW 18.90 A 15 A 10 A 6.80 kW

At 04:31, approximately 13.09 A remained on the most loaded phase, enough for the 13 A EV setting. At 04:35, approximately 18.91 A remained, exceeding the 15 A EV setting. The 04:40 sample is near the working limit if a full extra 15 A is added (~24.65 A); it should not be described as proof of comfortable headroom throughout.

The plan computed around 04:38 explicitly scheduled approximately 10.35 kW EV + 4.81 kW battery, forecast house load 1.39 kW, total import 16.55 kW.

Independent site-meter power, after accounting for measured battery power, supports a real charging-load increase around 04:42, rather than merely delayed Easee power reporting. It is supporting evidence, not proof of the charger's internal cause.

Evidence boundaries

  • Accepted commands/dynamic settings, effective pilot and measured draw are distinct evidence.
  • Battery charging was reduced at EV startup, and sufficient measured headroom existed during part of the prolonged wait. Concurrent battery charging alone does not explain the entire delay.
  • The internal Easee allocation/queue state, applicable reason-code history and any other controlling writer have not been established.
  • Detailed control trace files had rotated by the time of investigation; the available trace started around 12:22 local time and cannot reconstruct the overnight reservation/clamp decisions.
  • Planner snapshots and stored series are available. No claim is made that a specific reservation algorithm or vendor endpoint is the proven root cause.

Requested investigation

  1. Trace the accepted dynamic limit/resume → effective pilot → actual draw transition, including fresh Easee allocation and no-current reason evidence.
  2. Verify whether pending EV reservations and concurrent battery charging remain consistent across long zero-pilot waits and replans.
  3. Explain zero pilot separately from a vehicle declining a positive pilot; do not attribute it to the car or to battery charging without evidence.
  4. Review retry timing and feedback against the driver's declared response time, without suppressing genuine prolonged nonresponse.
  5. Retain enough timestamped allocation/feedback evidence to diagnose a night-time incident later that day.
  6. Review completed-charge handling separately: at 06:24 the owner confirms the vehicle had reached its 80% limit, yet Core retried and logged no-charge. Preserve the distinction between confirmed completion, missing vehicle evidence and an unexplained failed start.

Diagnostic sources: /api/drivers/easee-cloud/logs, /api/series (Easee power, dynamic limit, effective pilot and current; Pixii grid/battery power and per-phase currents), /api/mpc/diagnose/history, /api/mpc/diagnose/at, /api/config, /api/loadpoints, and /api/control/trace. Credentials, device serials, VIN and home address are omitted.

Activity

  1. segran2 commented on Nov 12, 2026

    @segran2
    ContributorAuthor

    Follow-up from 12 November 2026 (CET, UTC+1), on the same Easee/Pixii installation with FTW v0.163.0-beta.1 and local Easee pilot diagnostics.

    Local time What FTW recorded
    03:24:27–03:24:52 FTW reported a site fuse limit as EV draw fell to zero. Pixii had been charging at about 6.8 kW and then reduced its draw.
    03:24:52–03:26:17 FTW requested 12 A per phase (8.28 kW). The charger reported a 12 A dynamic setting, 0 A pilot and 0 W measured EV power.
    03:26:17–03:28:27 FTW recorded no power response. The first and last control-journal snapshots both show 12 A requested and reported as the dynamic setting, 0 A pilot, 0 W draw, pilot mode B, and 0 A allocated on all three phases. Easee's reported reason label was “limited by dynamic charger current”. During the retries Pixii was near 0 kW and the highest measured grid phase was about 6.6 A.
    03:26:22, 03:26:52, 03:27:27 Three resume acknowledgements, each with 0 W observed. At 03:27:57 FTW logged that resume had been acknowledged but no charge was observed.
    03:28:27 / 03:45:17 FTW's requested power went to zero, then measured charging returned in the next planned slot.

    This reproduces the positive-setting/zero-pilot condition from the original report. The saved per-phase allocation confirms that Easee was reporting zero available current at the journal snapshots. Its reason label does not establish why that state persisted despite the 12 A readback. On the next occurrence, capture the original timestamps for the dynamic setting, per-phase allocation and no-current reason around each resume acknowledgement.

    Sources: FTW control journal (first and last EV snapshots), Easee driver logs and Pixii power/phase-current series.

  2. segran2 commented on Nov 18, 2026

    @segran2
    ContributorAuthor

    Easee Support provided the following explanation about Equalizer behavior. Translated from Swedish.

    When you use the Equalizer, it quickly reduces the charging current available to the charger when several electrical appliances are running. When household consumption falls again, it takes longer for the Equalizer to raise the charging current. This can take up to 15 minutes.

    The slower increase is intentional. It allows the Equalizer to make sure that the current is actually available. Some cars behave unpredictably when the available current rises and falls quickly, and many household appliances draw power unevenly. The Equalizer increases the current more slowly than it reduces it to avoid wearing out the charger's relays through repeated opening and closing.

    If the charger is locked to three-phase mode, all three phases must have more than 6 A available for charging to restart after the current has been reduced. The car's onboard charger requires the same current on each phase, so at least 6 A × 6 A × 6 A must be available to start three-phase charging. The onboard charger will not accept, for example, 6 A × 9 A × 12 A. It accepts only equal current on all three phases. Even if there is plenty of capacity overall because two phases are lightly loaded, the charger will receive only 6 A per phase if the third phase has just 6 A to spare.

    In automatic phase mode, the charger switches from three-phase to single-phase charging when needed. If the load is too high, it stops three-phase charging and starts charging on one phase. To protect the relays, the session then continues on one phase even if enough capacity becomes available on all three phases. To return to three-phase charging once enough capacity is available, manually pause and restart charging in the app.

    If your system has a high average load and you still want the highest possible average charging current, single-phase charging may work better. It lets the Equalizer allocate charging to the phase with the most spare capacity. You can try this by locking the charger to single-phase mode in the app under Charging settings.

  3. segran2 commented on Nov 18, 2026

    @segran2
    ContributorAuthor

    Follow-up on the 17 November restart

    Easee acknowledged three resume requests between 06:00:47 and 06:01:47 CET while FTW was requesting 7 A per phase and measuring 0 W. SignalR reported the dynamic limit going 7 → 32 → 7 A alongside reason codes 78 and 77. The trace ended after two minutes without fresh charging power. The last zero-pilot observation in that trace had a source timestamp from before the start attempt. The stored power series first showed 359 W at 06:14:29, then about 4.1 kW at 06:14:39. A separate manual start at 19:33 showed 14 A allocated on each phase and a 14 A pilot, with the first fresh power observation (91 W) after 5.1 seconds.

    The delayed start is consistent with Easee Support's description of Equalizer recovery taking up to 15 minutes after a reduction. The existing trace does not establish when headroom returned on each phase or why Easee held back this particular start.

    Diagnostic capture deployed on 18 November

    A local read-only collector is running on the Raspberry Pi. It samples every five seconds for up to 20 minutes from a plugged-in, positive charging request with little or no measured draw. Each record includes:

    • Pixii's grid current on all three phases and the measurement timestamps.
    • FTW's requested current, per-phase command ceiling, the actual current setting written to Easee and its write result. Resume acknowledgements are retained in the FTW journal.
    • Easee's dynamic setting, per-phase allocation, pilot, measured power and reason code, with both source and confirmation timestamps where available.

    The collector was verified against the running box after deployment. It can read all three Pixii phases and the added Easee diagnostics. The patch leaves the control logic unchanged. The next spontaneous delayed start is still pending. The next trace should show whether fresh Easee allocation stayed below the requested current after Pixii showed enough headroom on all three phases, and whether pilot and power rose when the allocation recovered.

  4. segran2 commented on Nov 18, 2026

    @segran2
    ContributorAuthor

    Scope after reviewing #1975

    Keep #1948 focused on delayed starts after Easee accepts a positive current setting and a resume request, while the charger reports zero pilot and no draw. Easee Support's explanation of delayed Equalizer recovery (up to 15 minutes after a current reduction) is consistent with the observed 10–14 minute waits. The available traces do not establish the Equalizer's decision in each case. In particular, #1975's 54-minute no-draw interval had a documented zero pilot at the beginning, with insufficient evidence to classify the entire interval as Equalizer recovery.

    The positive-pilot stops in #1975, the original control-loop stall with temporary Pixii control blocking, and retry behavior when vehicle charge completion lacks fresh SoC evidence remain separate questions. The merged #2008 and #2010 improve the feedback by showing pilot evidence and the charger-reported reason when available.

    The local diagnostics collector is active on the Pi. At this check its capture file was empty, so there is no new start trace to evaluate yet. The next useful trace is a spontaneous delayed start with timestamped Pixii phase currents, the FTW order and ceiling, and Easee allocation, pilot and measured draw through recovery.

  5. frahlg commented on Nov 21, 2026

    @frahlg
    Member

    Thanks for the traces and the Easee Support text. An open PR, #2050, makes Core wait up to 15 minutes while the charger's load balancing holds a start. Reasons the charger reports now show in the feedback (#2008, #2010). We still lack a trace of a delayed start with zero pilot. The collector on your Pi should catch the next one.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Metadata

Metadata

Assignees

No one assigned

    Labels

    No labels
    No labels

    Type

    No type

    Projects

    No projects

      Milestone

      No milestone

      Relationships

      None yet

      Development

      No branches or pull requests

      Issue actions