Skip to content

[bug] EV and Pixii charging anomalities #1975

Open

Description

@segran2

What happened?

EV and pixii charging works much better now after the last couple of weeks of beta updates, but still not entirely stable.

03:03–03:12 | The EV drew 0 W despite a request for 9.66 kW. Charging resumed at approximately 4.72 kW, limited by load balancing.

03:27–03:28 | FTW’s control loop stalled. The safety mechanism attempted to return the devices to autonomous operation; Pixii control was temporarily blocked and subsequently recovered.

04:18–05:12 | The EV showed no power response for approximately 54 minutes. At the start of the incident, Pixii was simultaneously charging at 6.95 kW, while the EV’s pilot current was 0 A.

05:45–05:55 | The EV drew 0 W despite a request for 10.35 kW. The warning cleared when the charging request changed to 0 W; this does not demonstrate that charging resumed.

N.B The 5:45 issue is no issue as the car was charged to 80%. The problem caused by FTW can't get fresh SoC from the car in real time.

Steps to reproduce

Run FTW according FTW plan.

Expected behavior

Charging to be balanced between Easee and Pixii within safe limits and without unexplained interruptions in Easee charging, 0W pilot a.s.o.

Version

v0.159.0-beta.1 + diagnostic patches to catch errors

Deployment

Native 0.x (install.sh)

Hardware / drivers in use

Pixii, Easee, SMA

Relevant logs

Anything else?

ftw-support-20261106-135957.zip

FTW-EV-Pixii-relevanta-incidenter-2026-11-06.zip

Activity

  1. added
    bug
    on Nov 6, 2026
  2. segran2 commented on Nov 12, 2026

    @segran2
    ContributorAuthor

    Follow-up from the night of 12 November 2026 (CET, UTC+1) on FTW v0.163.0-beta.1 with local Easee pilot diagnostics.

    • 03:47–03:52: FTW requested 15 A per phase (10.35 kW), Easee signalled 13 A, and the car drew about 8.91 kW. FTW recorded a load-balancing limit at informational severity. Similar limits were recorded later in the session.
    • 03:26–03:28: Easee reported a 12 A dynamic setting with a 0 A pilot, 0 A allocated on all three phases and 0 W draw. Three resume calls were acknowledged. Pixii was near 0 kW during the retries and the highest measured grid phase was about 6.6 A. The detailed timeline is in #1948.
    • From 04:35: Measured EV power went to 0 W while Easee still reported a positive pilot of 7–12 A in several journal snapshots. FTW alternated between no power response and vehicle declined. The available measurements do not establish why the vehicle stopped drawing power.
    • Control loop: No matching stall or watchdog warning appeared in the FTW service journal for the checked window, 03:00–05:00. That observation is limited to this window.

    The positive-pilot stop remains open for investigation. The next occurrence would benefit from timestamped pilot mode, the Easee reason code, and fresh vehicle SoC where available.

    Sources: FTW control journal, Easee driver logs, Pixii phase-current and battery-power series, and FTW service journal.

  3. segran2 commented on Nov 13, 2026

    @segran2
    ContributorAuthor

    Follow-up from 13 November 2026 (CET) on the Easee installation:

    • 18:00: FTW requested 15 A and Easee acknowledged the resume commands. Easee reported a 6 A pilot and 6 A allocated per phase, while measured EV power stayed at 0 W throughout the two-minute trace. The owner suspects the car had reached its 80% charge limit. There is no contemporaneous SoC measurement in the trace to verify that.
    • 18:29: FTW requested 14 A. Easee again reported a 6 A pilot and 6 A allocated per phase. Measured power became positive after about 6.6 seconds and reached 4.17 kW. Startup traces
    • 18:39: A separate test on the exact Easee Cloud 1.5.0 candidate for device-drivers PR Map port 80 -> 8080 on RPi image + Documentation reshuffle (#199) #200 showed a 15 A request, 6 A pilot and 4.18 kW measured. The driver identified load balancing. Hardware validation

    These runs show that the car can start with the 6 A pilot on this installation. The cause of the earlier stop despite a positive pilot and the separate FTW control-loop stall remain open. The prolonged zero-pilot starts are tracked in #1948.

  4. segran2 commented on Nov 18, 2026

    @segran2
    ContributorAuthor

    Follow-up after reviewing #1948

    Easee Support says Equalizer can take up to 15 minutes to raise the allowed current again after a reduction. That is consistent with the shorter zero-pilot restart delays. The 54-minute no-draw period reported here had a documented 0 A pilot at the beginning. We lack enough observations to attribute the full interval to Equalizer recovery. The next delayed start with zero pilot is tracked in #1948, where the new diagnostics record Pixii phase currents, FTW's command and current ceiling, and timestamped Easee allocation, pilot and power. Easee Support's explanation

    Two observations still need follow-up here:

    • No draw despite a positive pilot. On 12 November, several snapshots showed 7–12 A pilot with 0 W. The 13 November test confirmed that the car can start at 6 A on this installation. On recurrence, capture the pilot mode and reason code alongside fresh vehicle SoC and the vehicle's charge limit when available. The original 05:45 case, when the owner confirmed the car had reached 80%, remains relevant to retry and feedback behavior when FTW lacks fresh SoC.
    • FTW control-loop stall and temporary Pixii control block. Treat this as a separate event. There was no matching stall or watchdog warning in the later checked window, and the original stall remains unexplained.

    Merged PRs #2008 and #2010 improve the pilot and charger-reason feedback. The pending timestamp handling change in device-drivers #183 helps interpret the order of Easee observations in future traces.

  5. frahlg commented on Nov 21, 2026

    @frahlg
    Member

    Thanks for the detailed split. The Equalizer wait is covered in #1948 and the open PR #2050. The no-draw case with a positive pilot is still open. Next time, please keep the pilot mode, the reason code, and the car's SoC and charge limit if you have them. We need these to tell a car that stopped from a charger that held back.

  6. segran2 commented on Nov 21, 2026

    @segran2
    ContributorAuthor

    Hardware follow-up, 21 November 2026 (CET). We ran a controlled vehicle-side stop with a manual three-phase 8 A order (5.52 kW), starting at approximately 79% SoC with the charge limit set to 80% in the Audi app. The vehicle API did not report the charge limit, so 80% is operator-provided.

    Collector sample FTW sent Easee power Pilot Charger state
    20:09:29 5.52 kW 5.50 kW 8 A, mode C Charging (op mode 3)
    20:09:34 5.52 kW 0 W 8 A, mode B Completed (op mode 4), request inactive, reason 78 (“limited by dynamic charger current”)

    Easee timestamped the zero-power observation at 20:09:29 CET. The car remained plugged in. The positive FTW order and 8 A pilot persisted after the stop. The known vehicle charge limit, mode C → B and completed state make this a reference trace for a vehicle-side stop with a positive pilot, even though the charger also exposed reason 78. This does not establish the cause of earlier uncontrolled incidents.

    The Pi collector saved the samples immediately before and after the transition. Its first automatic classification marked the zero sample unverified because the preceding stable positive-power value retained an older source timestamp. The updated collector uses the recently recorded charging state as context and requires a newer zero-power sample plus a recent pilot confirmation. Replaying the real trace now yields confirmed no draw at 8 A. The updated collector is running on the Pi. Live validation of its automatic classification can wait for the next normal charge to 80%.

  7. segran2 commented on Nov 21, 2026

    @segran2
    ContributorAuthor

    Live collector follow-up, 22 November 2026 (CET). The operator reported 79% SoC and an 80% charge limit in the Audi app. In FTW, the loadpoint was configured for Auto and the manual order was 8 A on three phases (5.52 kW).

    Collector sample FTW sent Easee power Pilot Charger state
    00:01:32 5.52 kW 5.54 kW 8 A, mode C Charging
    00:01:37 5.52 kW 97 W 8 A, mode B Completed; reason 78 (limited by dynamic charger current)
    00:01:43 5.52 kW 97 W 8 A, mode B Completed; power sample classified as fresh

    The updated collector saved the lead-in and the transition live. Easee continued reporting 97 W through at least 00:02:23 in the captured samples, above the collector’s 1 W threshold for confirmed no draw. This run verifies live prehistory and freshness handling around a vehicle-side stop. The automatic positive-pilot/zero-power classification is still verified by replay of the earlier 0 W trace. After the test, Charge now was inactive and FTW returned to the plan with a 0 W order.

  8. segran2 commented on Nov 21, 2026

    @segran2
    ContributorAuthor

    Strict 0 W hardware follow-up, 22 November 2026 (CET). The operator started with 79% SoC and an 80% vehicle charge limit, used a manual 8 A three-phase order, then lowered the vehicle's charge limit to 70% after charging stabilized. The charge limit was operator-provided.

    Collector sample FTW sent Easee power Pilot Charger state
    00:16:47 5.52 kW 5.45 kW 8 A, mode C Charging
    00:16:52 5.52 kW 299 W 8 A, mode B Completed, reason 78
    00:16:57 5.52 kW 0 W 8 A, mode B Completed, reason 78
    00:17:02 5.52 kW 0 W 8 A, mode B Completed, reason 78; collector recorded confirmed_no_draw

    The updated collector saved the lead-in and automatically classified the strict 0 W case live while the pilot and FTW order were both still positive. This verifies the collector on hardware and provides a known vehicle-side stop for comparison with unexplained cases.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Metadata

Metadata

Assignees

No one assigned

    Labels

    bug

    Type

    No type

    Projects

    No projects

      Milestone

      No milestone

      Relationships

      None yet

      Development

      No branches or pull requests

      Issue actions