34 changes: 0 additions & 34 deletions .changeset/battery-what-it-can-do-now.md

This file was deleted.

5 changes: 0 additions & 5 deletions .changeset/bundle-battery-limits.md

This file was deleted.

17 changes: 0 additions & 17 deletions .changeset/fresh-pilot-explains-draw.md

This file was deleted.

18 changes: 0 additions & 18 deletions .changeset/readings-lost-sustained-gap.md

This file was deleted.

66 changes: 66 additions & 0 deletions CHANGELOG.md
Original file line number Diff line number Diff line change
@@ -1,5 +1,71 @@
# Changelog

## 0.167.0

### Minor Changes

- 1584f59: Judge a battery against what it can do now, not only against FTW's order.

A home box with a Sungrow hybrid sent 23 "not following" notices in two
weeks, though its battery did all it could. At night the inverter held grid
import at about 4.3 kW, so the battery took 4.3 kW less the house load; on
discharge the battery gave a flat 22 A.

Core now learns these limits per battery from its own control journal. When
a battery falls short of its order in the right direction and the grid
import, grid export, battery current or battery power stays flat, Core keeps
that run. Once the same level shows at least three times on two days, a
shortfall at that level reads "At its usual limit", with words such as "The
inverter takes at most 4.3 kW from the grid. FTW has seen this 14 times since
8 Nov." A battery that gives well below its limit still warns, and so does
one that gives less than half of its order, however often: a broken battery
never becomes normal. So a cold battery whose BMS lets it give, say, 46 % of
the order also stays a warning, unless its driver reports that limit. A grid limit counts only while the battery moves and
the meter shows live, changing readings, so a meter driver that resends a
cached value teaches nothing. A new, lower limit becomes normal only after it
repeats on two days, and the old one stays on record. Limits are kept per
temperature band when the battery reports its temperature.

A battery whose driver reports `available_charge_W` or
`available_discharge_W` reads "Limited by the battery" at once when it gives
that much. A battery whose driver reports `device_state` standby or starting
still warns, now with that reason. These verdicts change the words and the
status only; dispatch, the fuse guard and commands do not read them. GET
/api/battery_models shows the learned limits, and POST
/api/battery_models/reset forgets them along with the rest of the model.
Limited verdicts never send the "not following" notice.
- 0014493: Bundle the drivers that report what a battery can do now. Sungrow (1.7.0), Huawei, Kostal, Sigenergy, GoodWe, Solis, SolaX, SAJ, Deye, FoxESS, victron_mqtt and the Solis C&I and Konja drivers report the battery's temperature and, where the device documents one, its live charge and discharge limit; Sungrow also says when the inverter is on standby. No driver sends a battery temperature of 0 when the read fails any more. The bundle also carries the charger control from srcfl/device-drivers (go-e, OpenEVSE, Hardy Barth, Etrel, KEBA, Schrack; refused stand-downs for Alfen, ABB and Mennekes) that has so far been only in the drivers-beta channel. None of it is verified on hardware yet.

### Patch Changes

- e015cbe: Keep a charge under the charger's load balancing at Limited when the driver
briefly stops reporting its limit (srcfl/ftw#2056).

An Easee charger read back FTW's 13 A order while its load balancing
signalled 8 A to the car, which took 5.44 kW. The EV status said "Limited by
the charger's load balancing", then "Not following" for 15 s, then Limited
again, though the 8 A pilot reading was still fresh. The test driver, built
on the open pilot change in srcfl/device-drivers#200, stops reporting its
limit for up to 30 s after its order reading moves. Core now lets a fresh
pilot below the order explain a draw that matches it. The status stays
Limited and reads "Limited by the charger" with the pilot current, because
only the driver can name the load balancing. A car that takes far less than
the pilot is still Not following.
- 989dd07: Stop one late poll from reading as "Lost control".

A home box with a Sungrow hybrid logged 341 "Lost control" alarms for its
battery in two weeks, each one 5 s journal sample long. The journal samples
at its timer's time, and the status page takes its clock before it waits
for the controller. A battery poll stored in between looked newer than the
clock, so Core called the reading stale, and a stale reading became lost
readings at once. A charger that said it was offline for one poll did the
same. Core now judges a device at the latest of its own clock and the
store's stamps on what it read. Readings count as lost once neither
measured power nor a new order has come for 30 s, or 2 min for a charger,
the same grace a new order gets. A reading over a minute old, or a driver
the watchdog gave up on, is still lost at once. Dispatch and the stale site
meter stop are unchanged.

## 0.166.0

### Minor Changes
Expand Down
4 changes: 2 additions & 2 deletions package-lock.json

Some generated files are not rendered by default. Learn more about how customized files appear on GitHub.

2 changes: 1 addition & 1 deletion package.json
Original file line number Diff line number Diff line change
@@ -1,6 +1,6 @@
{
"name": "ftw",
"version": "0.166.0",
"version": "0.167.0",
"private": true,
"type": "module",
"description": "FTW — local-first home energy coordination. Version metadata only; the runtime is Go and the mathematical planner is the compiled Energyplan worker.",
Expand Down