docs: the on-setting is wrong on entry and right after it - #143
#142 established that switching into an element mode engages the element on a
differential the device does not publish, and concluded that heUpperOnTempSetting"is not being driven by that field". The first half is
right; the generalisation is not — and it left this reference contradicting
itself, since data_conversions.rst describes these fields as thermostats while #142's warning said flatly that they do not predict when an element runs.
Both were true only of the moment a mode is switched.
Later in the same stint, the published description is exactly right
From one unit's recorded history:
Mode
mid-stint starts
probe in 39.4–41.1 degC
median vs heUpperOnTempSetting
ENERGY_SAVER
23
17
0.2 degC below
HIGH_DEMAND
12
0
2.1 degC below
In ENERGY_SAVER the on-setting rests at 40.5 degC and the element comes on as
the probe reaches it — the field working as documented.
HIGH_DEMAND is the contrast that makes the point: its on-setting tracks the
setpoint, and its mid-stint starts come 2.1 degC below that, nowhere near the
device-minimum band. That differential is real and published nowhere.
So entry is the exception and the reference description is the rule.
What changed
heating-elements.rst — the summary row narrowed to "on entry", a new row
for later in a stint, and the "what the on-setting does and does not tell you"
section rewritten with a per-mode entry/mid-stint table.
data_conversions.rst — the warning docs: what the heating elements actually do #142 added said flatly that these
fields do not predict when an element runs. It now says which rule applies
when.
device_status.rst — same narrowing.
CHANGELOG.rst — the entry is still Unreleased and is docs: what the heating elements actually do #142's own, so it
is amended rather than contradicted; nothing has shipped with the broad claim.
Limits — "what engages the element later in an Energy Saver stint" was
listed as not established. It now is, from history. What remains unestablished
is Electric's mid-stint behaviour, which has only two starts on record.
A sampling note that travels with the figures
An earlier revision of this PR claimed the element binary sensors assert
one-minute elements the meter never sees. That was wrong — an adversarial
review of the analysis caught it, and the commit history here shows the
correction.
The short elements are real. On 2026-04-12 the flag ran 22:21:58 → 22:22:18
and currentPower inside reads 5558 W and 5547 W, compressor steady at
~470 W either side. The "538 W" that made it look phantom was the last sample
at or before the minute boundary — a one-minute resample using a backward
as-of join instead of a maximum. currentPower samples at a median 30 s with
24 % of gaps over a minute, so a sub-minute burst falls between the samples
such a resample keeps.
What is true, and more useful: element runs come in two lengths. Of 128 raw
upper-element runs, 31 (24 %) are under a minute — median 9 s — and together
carry 0.8 kWh across nine months against 97.9 kWh for the other 97. A
20-second burst moves the probe ~0.1 degC, at its own resolution. So resample
power with a maximum or work from raw edges, and filter on duration or
energy when predicting recovery.
No mid-stint figure in this PR changes. The review confirmed the Energy
Saver and High Demand results are identical with or without the power filter.
Scope
These are history-derived, not commanded runs, and the page labels them that
way — #142's bounded device runs remain the source for the entry thresholds. he_upper_on is recorded for only 8 of the 23 Energy Saver starts and 6 of the
12 High Demand ones; the rest rest on the probe clustering in the same band.
Docs build clean (no new Sphinx warnings against baseline).
Update: confirmed on the device, and two retractions
The Energy Saver on-point is now confirmed by a commanded run (one unit, 2026-09-21), not just history. History could not separate "at heUpperOnTempSetting" from "a fixed gap below the setpoint", because the setpoint barely moved. With it lowered to 42.0 degC, a fixed gap predicted engagement near 22 degC; the element engaged three times at an upper-probe reading of 39.8 degC. Cautions: all three came with water moving through the tank, and the working threshold may be a little under the published 40.5.
Also added, each with its n: the element runs to ~0.9 degC under the setpoint-tracking heUpperOffTempSetting rather than to a fixed point; raising the setpoint in ENERGY_SAVER starts the element through the entry rule (n = 1); and demand versus temperature alone cannot be separated from these runs.
Retracted:
The short-element warning said a 20 s burst "heats nothing" (~0.1 degC). That used the whole tank's heat capacity; it is ~0.3 degC, and 41–58 s bursts measured 0.7–1.5 degC. Counts restated on a clean basis: 115 upper-element runs, 20 under a minute, median 16 s.
The page said heUpperOnTempSetting rests at 40.5 degC in HEAT_PUMP as well as ENERGY_SAVER. It does in Energy Saver (96 % of minutes); in Heat Pump only 48.5 %, and the other values match the current setpoint only 6 % of the time. Now marked unreliable in Heat Pump mode.
#142 established that switching into an element mode engages the
element on a differential the device does not publish, and concluded
that heUpperOnTempSetting "is not being driven by that field". The
first half is right. The generalisation is not, and it made this
reference contradict itself: data_conversions.rst describes these
fields as thermostats, #142 added a warning saying they do not predict
when an element runs, and both were then true only of the moment a
mode is switched.
Later in the same stint the published description is exactly right. In
23 mid-stint upper-element starts in ENERGY_SAVER, drawn from one
unit's recorded history, 17 have the probe in the 39.4-41.1 degC band
where heUpperOnTempSetting rests, and where the field itself is
recorded the median start is 0.2 degC below it. The element comes on
as the probe reaches the on-setting.
HIGH_DEMAND is the contrast that makes the point: its on-setting
tracks the setpoint, and 12 mid-stint starts came a median 2.1 degC
*below* it, none anywhere near that band. That differential is real
and published nowhere.
So entry is the exception and the reference description is the rule.
Narrowed in four places: the explanation page's summary row and its
"what the on-setting does and does not tell you" section, which now
carries a per-mode entry/mid-stint table; data_conversions.rst's
warning, which said flatly that these fields do not predict when an
element runs and now says which rule applies when; device_status.rst's
note; and the unreleased changelog entry, amended rather than
contradicted since nothing has shipped with the broad claim.
One measurement note travels with the new figures, because anyone
repeating this will hit it. This unit's element binary sensors assert
one-minute elements the power meter never sees: 9 of 112 apparent
upper-element starts drew 750 W or less, against 5.1-5.6 kW for a real
one, while every run of two minutes or more was genuine. Element
starts counted from those sensors alone are overstated. Every figure
here is corroborated against the whole-unit power reading.
These are history-derived, not commanded runs, and the page says so.
Refs #142
The reason will be displayed to describe this comment to others. Learn more.
Fixed in 6f9f0c0. Right — the later-stint rule is mode-specific. The changelog now reads "Later in a stint it depends on the mode": in ENERGY_SAVER entry is the exception and the reference description is the rule; in HIGH_DEMAND it is not (re-engages ~2.1 degC below the ON setting); ELECTRIC is uncharacterised.
The reason will be displayed to describe this comment to others. Learn more.
Fixed in 6f9f0c0. The opening now says how far the fields hold by mode and moment instead of flatly that they don't: not on entry to any element mode; yes later in ENERGY_SAVER (history, and now confirmed by a commanded run); no later in HIGH_DEMAND (history only); ELECTRIC uncharacterised. That also separates the history-derived evidence from the commanded run, as you asked.
The reason will be displayed to describe this comment to others. Learn more.
Fixed in 6f9f0c0 — scoped to ENERGY_SAVER, with HIGH_DEMAND's ~2.1 degC-below re-engagement moved into the same bullet so the lead-in no longer contradicts it. While there I also scoped "the ON setting is 33 degC below the tank in HEAT_PUMP and ENERGY_SAVER" to Energy Saver: this PR already found the field unreliable in Heat Pump mode (40.5 degC in only ~48.5 % of minutes).
The reason will be displayed to describe this comment to others. Learn more.
Fixed in 6f9f0c0. The lead-in is now "Later in a stint it depends on the mode", then ENERGY_SAVER (as the field describes), HIGH_DEMAND (does not — ~2.1 degC below), ELECTRIC (uncharacterised).
The warning added with the mid-stint figures said this unit's element
binary sensors "assert one-minute elements the power meter does not
see", with 9 of 112 apparent starts drawing 500-750 W or less. That is
wrong, and an adversarial review of the analysis behind it caught it.
The elements were real. Pulling raw samples: on 2026-04-12 the flag
went on at 22:21:58 and off at 22:22:18, and currentPower inside that
window reads 5558 W and 5547 W, with the compressor steady at ~470 W
either side. A 20-second element at full power. The "538 W" that made
it look phantom was the last sample at or before the minute boundary,
taken by a one-minute resample that used a backward as-of join instead
of a maximum. currentPower samples at a median 30 s with 24 % of gaps
over a minute, so a sub-minute burst falls between the samples such a
resample keeps.
What is true, and more useful, is that element runs come in two
lengths. Of 128 raw upper-element runs, 31 (24 %) are under a minute,
median 9 s, and together carry 0.8 kWh across nine months against
97.9 kWh for the other 97. A 20-second burst moves the upper probe
about 0.1 degC, at its own resolution — which is why "the tank did not
move" looked like corroboration and was not evidence either way.
So the note now describes the sampling hazard rather than accusing the
sensor: resample power with a maximum or work from raw edges, and
filter on duration or energy when predicting recovery, because it is
the sustained runs that heat the tank.
No mid-stint figure changes: the review confirmed the Energy Saver and
High Demand results are identical with or without the power filter.
Refs #142
…aims
A commanded run on 2026-09-21 answers what the recorded history on this
page could not. With the setpoint fixed for almost the whole record,
"the element engages at heUpperOnTempSetting" and "it engages a fixed
gap below the setpoint" made the same prediction. So the setpoint was
lowered to 42.0 degC and the unit left in ENERGY_SAVER. A fixed gap
predicted engagement near 22 degC; it engaged three times with the
upper probe at 39.8. The on-setting is what drives it — with two
cautions stated: every engagement came while water moved through the
tank, and readings of 40.4, 40.1 and 40.0 did not trigger, so the
working threshold may sit a little under the published 40.5.
Three further behaviours from the same run, each with its n:
- The element runs to ~0.9 degC under the setpoint-tracking
heUpperOffTempSetting, not to a fixed point. Only engagement is fixed.
- Raising the setpoint in ENERGY_SAVER starts the element, through the
entry rule (n = 1). A controller writing setpoints in that mode can
start a 5 kW element.
- Whether water movement is required, or temperature suffices, cannot
be separated: all three engagements had it, one from a shower and two
from a recirculation pump on a cooled loop.
Two retractions.
The short-element warning said a 20-second burst moves the upper probe
~0.1 degC, "below its own resolution. They heat nothing." That divided
by the whole tank's heat capacity; the upper element heats the upper
zone, a third of it. A 20 s burst is ~0.3 degC, and measured 41-58 s
bursts moved it 0.7-1.5 degC. The counts are also restated on a clean
basis — upper element only, commanded test days excluded, at the
fitted 5,148 W: 115 runs, 20 under a minute.
And the page said heUpperOnTempSetting rests at 40.5 degC in both
HEAT_PUMP and ENERGY_SAVER. True of Energy Saver (96 % of minutes on
this unit); in Heat Pump only 48.5 %, and the other values match the
current setpoint in only 6 % of minutes, so it is not tracking the
setpoint either. Marked as unreliable in Heat Pump mode.
Refs #142
Mark Heat Pump behavior unreliable in all descriptions
docs/explanation/heating-elements.rst:56
The PR update also retracts the mode-wide claim that the setting rests at 40.5 degC in Heat Pump, but the short-version row immediately above this changed entry text still states that as a fact (and the detailed section repeats it). Mark Heat Pump unreliable here and in the detailed description so this page does not retain the retracted generalization.
Add qualified Energy Saver setpoint and off-setting results
docs/explanation/heating-elements.rst:261
The update says the Energy Saver on-point is now supported by a commanded run (setpoint 42.0 degC, n=3 at 39.8 degC, all with water movement, possibly slightly below 40.5), but this paragraph still presents only the 17/23 historical clustering as "exactly" causal. It also omits the update's qualified off-setting and setpoint-raise observations. Add those results with their sample sizes and caveats, or align the PR description with the actual page.
This issue also appears on line 294 of the same file.
The update retracts the Heat Pump part of this generalization: the setting is 40.5 degC in only 48.5% of Heat Pump minutes, and the remaining observations do not establish the same entry behavior as Energy Saver. Saying both modes are sitting 33 degC below the tank is therefore inaccurate; qualify this statement to Energy Saver and mark Heat Pump behavior unreliable.
The reason will be displayed to describe this comment to others. Learn more.
Already addressed in 9ad7f34, which landed at 16:27Z, just before this review at 16:36Z — the Unreleased note now gives the corrected basis (115 upper-element runs, 20 under a minute, median 16 s) and says the short runs are real thermal input (~0.3 degC for a 20 s burst), not "heat nothing".
Review on #143 found four places that said the published thermostat
description holds later in a stint, then gave High Demand — which
re-engages ~2.1 degC *below* its ON setting — as a counterexample in
the next clause. The evidence supports the ON-setting description for
ENERGY_SAVER only.
- The page's opening said the four fields do not describe when the
elements run, which contradicted the row beneath it saying they are
the rule later in a stint. It now says how far they hold by mode and
moment: not on entry to any element mode; yes later in ENERGY_SAVER
(history, confirmed by a commanded run); no later in HIGH_DEMAND
(history only); ELECTRIC uncharacterised.
- CHANGELOG, data_conversions.rst and device_status.rst said "the
reference description is the rule" / "the descriptions below hold" /
"later in a stint they do". Each is now scoped to the mode.
- data_conversions.rst also still said the ON setting sits 33 degC
below the tank in HEAT_PUMP and ENERGY_SAVER. This PR already found
that true of Energy Saver and unreliable in Heat Pump; scoped to
match.
The fifth comment, on the changelog's short-element counts, was
already addressed in 9ad7f34.
Refs #142
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
#142 established that switching into an element mode engages the element on a
differential the device does not publish, and concluded that
heUpperOnTempSetting"is not being driven by that field". The first half isright; the generalisation is not — and it left this reference contradicting
itself, since
data_conversions.rstdescribes these fields as thermostats while#142's warning said flatly that they do not predict when an element runs.
Both were true only of the moment a mode is switched.
Later in the same stint, the published description is exactly right
From one unit's recorded history:
heUpperOnTempSettingENERGY_SAVERHIGH_DEMANDIn
ENERGY_SAVERthe on-setting rests at 40.5 degC and the element comes on asthe probe reaches it — the field working as documented.
HIGH_DEMANDis the contrast that makes the point: its on-setting tracks thesetpoint, and its mid-stint starts come 2.1 degC below that, nowhere near the
device-minimum band. That differential is real and published nowhere.
So entry is the exception and the reference description is the rule.
What changed
heating-elements.rst— the summary row narrowed to "on entry", a new rowfor later in a stint, and the "what the on-setting does and does not tell you"
section rewritten with a per-mode entry/mid-stint table.
data_conversions.rst— the warning docs: what the heating elements actually do #142 added said flatly that thesefields do not predict when an element runs. It now says which rule applies
when.
device_status.rst— same narrowing.CHANGELOG.rst— the entry is still Unreleased and is docs: what the heating elements actually do #142's own, so itis amended rather than contradicted; nothing has shipped with the broad claim.
listed as not established. It now is, from history. What remains unestablished
is Electric's mid-stint behaviour, which has only two starts on record.
A sampling note that travels with the figures
An earlier revision of this PR claimed the element binary sensors assert
one-minute elements the meter never sees. That was wrong — an adversarial
review of the analysis caught it, and the commit history here shows the
correction.
The short elements are real. On 2026-04-12 the flag ran 22:21:58 → 22:22:18
and
currentPowerinside reads 5558 W and 5547 W, compressor steady at~470 W either side. The "538 W" that made it look phantom was the last sample
at or before the minute boundary — a one-minute resample using a backward
as-of join instead of a maximum.
currentPowersamples at a median 30 s with24 % of gaps over a minute, so a sub-minute burst falls between the samples
such a resample keeps.
What is true, and more useful: element runs come in two lengths. Of 128 raw
upper-element runs, 31 (24 %) are under a minute — median 9 s — and together
carry 0.8 kWh across nine months against 97.9 kWh for the other 97. A
20-second burst moves the probe ~0.1 degC, at its own resolution. So resample
power with a maximum or work from raw edges, and filter on duration or
energy when predicting recovery.
No mid-stint figure in this PR changes. The review confirmed the Energy
Saver and High Demand results are identical with or without the power filter.
Scope
These are history-derived, not commanded runs, and the page labels them that
way — #142's bounded device runs remain the source for the entry thresholds.
he_upper_onis recorded for only 8 of the 23 Energy Saver starts and 6 of the12 High Demand ones; the rest rest on the probe clustering in the same band.
Docs build clean (no new Sphinx warnings against baseline).
Refs #142
Update: confirmed on the device, and two retractions
The Energy Saver on-point is now confirmed by a commanded run (one unit, 2026-09-21), not just history. History could not separate "at
heUpperOnTempSetting" from "a fixed gap below the setpoint", because the setpoint barely moved. With it lowered to 42.0 degC, a fixed gap predicted engagement near 22 degC; the element engaged three times at an upper-probe reading of 39.8 degC. Cautions: all three came with water moving through the tank, and the working threshold may be a little under the published 40.5.Also added, each with its n: the element runs to ~0.9 degC under the setpoint-tracking
heUpperOffTempSettingrather than to a fixed point; raising the setpoint inENERGY_SAVERstarts the element through the entry rule (n = 1); and demand versus temperature alone cannot be separated from these runs.Retracted:
heUpperOnTempSettingrests at 40.5 degC inHEAT_PUMPas well asENERGY_SAVER. It does in Energy Saver (96 % of minutes); in Heat Pump only 48.5 %, and the other values match the current setpoint only 6 % of the time. Now marked unreliable in Heat Pump mode.Docs build clean against baseline.