38 changes: 34 additions & 4 deletions CHANGELOG.rst
Original file line number Diff line number Diff line change
Expand Up @@ -9,7 +9,8 @@ Documentation
-------------
- **New: what the heating elements actually do**
(``docs/explanation/heating-elements.rst``). The four
``he*TempSetting`` fields do not describe when an element runs: in
``he*TempSetting`` fields describe the thermostat, and **on entry to
a mode the thermostat is not what runs the element**: in
Electric and High Demand the on and off settings are the same value,
and every ``he*DiffTempSetting`` reads 0. Measured on one unit by
commanding the modes and watching, the start differential is
Expand All @@ -22,9 +23,38 @@ Documentation
are **entry** thresholds, not thermostats: in High Demand's steady
state this unit's history has the element on in 1 of 47 minutes
0.2-0.3 degC short and 168 of 169 more than 2.2 degC short.
Neither differential is published anywhere in the status message. Also documents Energy
Saver's entry behaviour (the element engages although
``heUpperOnTempSetting`` rests 33 degC below the tank), Electric's
Neither differential is published anywhere in the status message.

**Later in a stint it depends on the mode.** From one
unit's recorded history, 17 of 23 mid-stint upper-element starts in
``ENERGY_SAVER`` have the probe in the 39.4-41.1 degC band where
``heUpperOnTempSetting`` rests, a median 0.2 degC below the field -
the element comes on as the probe reaches it. ``HIGH_DEMAND``, whose
ON setting tracks the setpoint, re-engages a median 2.1 degC *below*
it, which the field does not describe. So in ``ENERGY_SAVER`` entry is
the exception and the reference description is the rule; in
``HIGH_DEMAND`` it is not; ``ELECTRIC`` is uncharacterised.
``data_conversions.rst``'s warning now says which applies when.
A sampling note with it: the element runs in two very different
lengths. Of 115 upper-element runs over eight months, 20 lasted under
a minute (median 16 s), carrying 0.6 kWh against 93 kWh for the rest.
They are real elements, and not negligible to the probe - a 20 s burst
is ~0.3 degC. Because ``currentPower`` samples at a median 30 s, a
one-minute-resampled power series can miss one entirely, making a
5.5 kW element look like 0.5 kW. Resample power with a maximum.

Confirmed on the device, one unit, 2026-09-21: in ``ENERGY_SAVER``
the upper element engages near ``heUpperOnTempSetting`` rather than a
fixed gap below the setpoint (setpoint lowered to 42.0 degC; a gap
predicted 22 degC; it engaged at 39.8, three times). It then runs to
~0.9 degC under the setpoint-tracking ``heUpperOffTempSetting``, not
to a fixed point. Raising the setpoint in that mode starts the element
through the entry rule. And ``heUpperOnTempSetting`` rests at 40.5
degC reliably only in ``ENERGY_SAVER`` - in ``HEAT_PUMP`` about half
the time.

Also documents Energy Saver's entry behaviour (the element engages
although ``heUpperOnTempSetting`` rests 33 degC below the tank), Electric's
upper-to-lower handover and the upper probe **falling** 1.9 degC while
the lower element runs, measured element power of 5,219 W against the
5,000 W rating, and that a mode write may not take effect while a TOU
Expand Down
166 changes: 141 additions & 25 deletions docs/explanation/heating-elements.rst
Original file line number Diff line number Diff line change
Expand Up @@ -4,11 +4,22 @@ The Heating Elements

The NWP500 publishes four element thermostat settings -
``heUpperOnTempSetting``, ``heUpperOffTempSetting`` and their lower-zone
pair - plus a differential for each. Read literally they do not describe
when the elements actually run: in Electric and High Demand the on and
off settings are **the same value**, and every ``he*DiffTempSetting``
reads 0. The device nevertheless has a differential, and this page
gives the measured one.
pair - plus a differential for each. Read literally they describe a
thermostat, and how far that holds depends on the mode and the moment:

* **On entry to any element mode they do not** describe when the element
runs. It engages on a mode-dependent differential of its own, published
nowhere - the start thresholds below.
* **Later in a stint, in** ``ENERGY_SAVER`` **they do**: the element
engages as the probe reaches ``heUpperOnTempSetting``. That is from this
unit's history and confirmed by a commanded run.
* **Later in a stint, in** ``HIGH_DEMAND`` **they do not**: it re-engages
about 2.1 degC below its ON setting. That is from history only.
``ELECTRIC`` is uncharacterised.

The fields also look wrong as a thermostat taken literally: in Electric
and High Demand the on and off settings are **the same value**, and every
``he*DiffTempSetting`` reads 0.

**The start thresholds** here were measured on one unit by commanding
the modes and watching - not inferred from historical logs. That
Expand Down Expand Up @@ -48,15 +59,23 @@ The short version
read 0 on this unit while the behaviour above holds.
* - ``heUpperOnTempSetting`` by mode
- ``ELECTRIC`` and ``HIGH_DEMAND``: the setpoint, same as
``heUpperOffTempSetting``. ``HEAT_PUMP`` and ``ENERGY_SAVER``:
40.5 degC (104.9 degF), the device minimum.
``heUpperOffTempSetting``. ``ENERGY_SAVER``: 40.5 degC
(104.9 degF), the device minimum, in 96 % of recorded minutes on
this unit. ``HEAT_PUMP``: 40.5 degC only about **half** the time;
the rest are other values that match the current setpoint only
6 % of the time. Why is not known.
* - Energy Saver on entry
- Switching into ``ENERGY_SAVER`` engages the upper element even
though ``heUpperOnTempSetting`` rests 33 degC below the tank, so
whatever drives it, that field is not it. Its bracket also sits
higher than the other two modes'. Why the two differ is **not**
established: the Energy Saver runs had the compressor running
and the others did not.
**on entry** that field is not what drives it. Its bracket also
sits higher than the other two modes'. Why the two differ is
**not** established: the Energy Saver runs had the compressor
running and the others did not.
* - Energy Saver later in a stint
- Different rule. The element re-engages **as the upper probe
reaches** ``heUpperOnTempSetting`` - the field working exactly
as this reference describes it. Entry is the exception, not the
rule.
Comment on lines +74 to +78

Copy link
Copy Markdown
Owner Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Fixed in 6f9f0c0. The opening now says how far the fields hold by mode and moment instead of flatly that they don't: not on entry to any element mode; yes later in ENERGY_SAVER (history, and now confirmed by a commanded run); no later in HIGH_DEMAND (history only); ELECTRIC uncharacterised. That also separates the history-derived evidence from the commanded run, as you asked.

* - Electric ordering
- Upper element to the setpoint, then the lower element, never
both, as the protocol reference already states. The handover
Expand Down Expand Up @@ -235,21 +254,117 @@ What the on-setting does and does not tell you
with no hysteresis at all, which cannot be how the device behaves; on
entry the measured differential is at most 0.3 degC in Electric and
within (0.2, 0.7] degC in High Demand.
* In ``HEAT_PUMP`` and ``ENERGY_SAVER`` it rests at 40.5 degC, the
device minimum, which is 33 degC below a normally charged tank.

The second case is the one that misleads. In ``ENERGY_SAVER`` the upper
element **does** run, and it runs with the on-setting far below the tank
- so the element is not being driven by that field. Switching into the
mode with the tank 1.0 degC or more short brought the element on within
one poll in both runs tested, and ``heUpperOnTempSetting`` dropped from
the setpoint to 40.5 degC in the *same* status message. Watching that
field for an explanation of the element will not find one.

That is as far as the observation goes. It does not explain *why*
* In ``ENERGY_SAVER`` it rests at 40.5 degC, the device minimum, which
is 33 degC below a normally charged tank. An earlier version of this
page said the same of ``HEAT_PUMP``; on this unit that holds in only
48.5 % of Heat Pump minutes. The rest are other values - 63.0 degC
most often - which equal the *current* setpoint in only 6 % of Heat
Pump minutes, so this is not the field tracking the setpoint; it may
be holding a value over from an earlier mode. Do not rely on it in
Heat Pump mode.

The second case misleads **on entry only**. Switching into
``ENERGY_SAVER`` with the tank 1.0 degC or more short brought the upper
element on within one poll in both runs tested, while
``heUpperOnTempSetting`` dropped from the setpoint to 40.5 degC in the
*same* status message - 33 degC below the probe. For that moment the
field explains nothing.

That is as far as the entry observation goes. It does not explain *why*
Energy Saver's bracket sits higher than Electric's; the runs differ in
compressor state as well as mode, and nothing here separates the two.

**Later in the same stint the field is exactly what drives the
element.** In 23 mid-stint upper-element starts in ``ENERGY_SAVER``
drawn from one unit's recorded history, **17 have the upper probe
between 39.4 and 41.1 degC** - the band ``heUpperOnTempSetting`` rests
in for this mode - and where the field itself is recorded the median
start is **0.2 degC below it**. The element comes on as the probe
reaches the on-setting, which is what this reference has said all
along.

**Confirmed on the device.** The history above cannot prove it on its
own: with the setpoint fixed for almost the whole record, "at the
on-setting" and "a fixed gap below the setpoint" are the same
prediction. So the setpoint was lowered to 42.0 degC and the unit left
in ``ENERGY_SAVER``. With the on-setting still at 40.5 degC, a fixed gap
would have put the element near 22 degC; it came on three times with
the upper probe reading **39.8 degC**. Two cautions: all three came
while water was moving through the tank, and readings of 40.4, 40.1 and
40.0 degC did not trigger, so on this probe the working threshold may
sit a little under the published 40.5.

``HIGH_DEMAND`` behaves differently, and this is the clearest statement
of the difference on this page. There ``heUpperOnTempSetting`` tracks
the setpoint, and 12 mid-stint starts came a median **2.1 degC below
it**, none in the 39.4-41.1 degC band. That differential is real and is
published nowhere.

So a consumer needs both halves:

.. list-table::
:header-rows: 1
:widths: 26 37 37

* - Mode
- On entry
- Later in the stint
* - ``ENERGY_SAVER``
- element on, on-setting irrelevant (1.0 degC below setpoint)
- element on **near** ``heUpperOnTempSetting``
* - ``HIGH_DEMAND``
- element on, (0.2, 0.7] degC below setpoint
- element on ~2.1 degC **below** ``heUpperOnTempSetting``

Three more behaviours, from the same commanded run. Each is one unit
and one morning; the counts are given so they can be weighed.

* **The element runs to the setpoint, not to a fixed point.** It
stopped about 0.9 degC under ``heUpperOffTempSetting``, which follows
the setpoint. At a 42.0 degC setpoint that was 41.1 degC; historical
runs at a 60.5 degC setpoint stop around 59. Only the *engagement*
point is fixed.
* **Raising the setpoint in** ``ENERGY_SAVER`` **starts the element.**
With the tank at 41.7 degC, a setpoint raise to 61.0 degC switched the
heat source to heat pump plus element in the same second (n = 1). It
is the entry rule again, triggered by the setpoint rather than a mode
change. A controller writing setpoints in this mode can start a 5 kW
element.
* **Every engagement came with water moving through the tank** — one
shower and two runs of a recirculation pump on a cooled loop, which
the tank experiences as draws. Whether movement is *required*, or the
temperature alone suffices, is not separable from these.

.. warning::

These mid-stint figures come from **recorded history, not commanded
runs**, and they carry a sampling hazard worth repeating - one that
bit us.

**The element runs in two very different lengths.** Of 115 raw
upper-element runs on this unit over eight months, 20 (17 %) lasted
**under a minute** - median 16 s - and 95 ran a median 8 minutes.
The short ones are real elements at full power. They carry little
energy - 0.6 kWh across the record against 93 kWh for the rest -
but they are not negligible to the probe: a 20-second burst raises
the upper zone about 0.3 degC, three quanta of its 0.1 degC
resolution, and measured bursts of 41-58 s moved it 0.7-1.5 degC.
*(An earlier version said they "heat nothing", from dividing by the
whole tank's heat capacity rather than the upper zone's - three
times too large.)*

They are also easy to lose or to misread. ``currentPower`` samples
at a median 30 s, with 24 % of gaps over a minute, so **a
one-minute-resampled power series can miss a sub-minute burst
entirely** - taking the last sample at or before each minute makes a
real 5.5 kW element look like 0.5 kW. Resample power with a
**maximum** over the interval, or work from the raw edges, and
corroborate a run's duration rather than a single aligned sample.

For predicting recovery, filter on **duration or energy**, not on
the flag and not on one power reading: it is the sustained runs that
heat the tank.


Electric: the handover, and what happens to the upper zone
===========================================================
Expand Down Expand Up @@ -326,8 +441,9 @@ established:
has a run on each side, so it is bracketed - but that bracket is more
than twice Electric's width, and one run at 0.4 degC would halve it.
Until then, whether the two modes share a threshold is unresolved.
* what engages the element **later** in an Energy Saver stint, as
opposed to on entry.
* **Electric's** behaviour later in a stint. Energy Saver's and High
Demand's are described above from history; Electric has only two
mid-stint starts on record, which characterises nothing.
* anything about runs longer than six minutes.
* whether either differential is firmware-dependent. The unit reported
``heUpperOnDiffTempSetting`` as 0 throughout; if another unit reports
Expand Down
33 changes: 21 additions & 12 deletions docs/reference/protocol/data_conversions.rst
Original file line number Diff line number Diff line change
Expand Up @@ -166,18 +166,27 @@ Electric heating elements are controlled via thermostat ranges. Two sensors (upp

.. warning::

**These fields do not predict when an element runs.** The
descriptions below are the protocol's own semantics for each field.
Measured against the device, they do not hold: in ``ELECTRIC`` and
``HIGH_DEMAND`` the ON and OFF settings are **the same value** (no
hysteresis at all, which cannot be how the device behaves), in
``HEAT_PUMP`` and ``ENERGY_SAVER`` the ON setting rests at the
40.5 degC device minimum while the element still runs, and **every**
``he*DiffTempSetting`` reads 0 rather than the 2-5 degF below.

The differential the device actually uses is mode-dependent and is
published nowhere in the status message. See
:doc:`/explanation/heating-elements` for the measured values.
**These fields describe the thermostat, and the thermostat is not
the whole story.** Measured against the device:

- **Later in a stint it depends on the mode.** In ``ENERGY_SAVER``
the upper element comes on as the probe reaches
``heUpperOnTempSetting``, as described below. In ``HIGH_DEMAND`` it
does not: it re-engages about 2.1 degC *below* its ON setting.
``ELECTRIC`` is uncharacterised.
- **On entry to a mode they do not.** Switching into an element mode
engages the element on a mode-dependent differential of its own,
while in ``ENERGY_SAVER`` the ON setting is sitting 33 degC below
the tank. That differential is published
nowhere.
- In ``ELECTRIC`` and ``HIGH_DEMAND`` the ON and OFF settings are
**the same value** - no hysteresis at all, which cannot be how the
device behaves.
- **Every** ``he*DiffTempSetting`` reads 0 on a 9.x-firmware unit
rather than the 2-5 degF described below.

See :doc:`/explanation/heating-elements` for the measured values and
which rule applies when.

.. list-table::
:header-rows: 1
Expand Down
18 changes: 11 additions & 7 deletions docs/reference/protocol/device_status.rst
Original file line number Diff line number Diff line change
Expand Up @@ -739,13 +739,17 @@ Technical Notes
* Elements do not operate simultaneously in Electric mode - upper first,
then lower, with the handover in a single status message
* Heating elements activate for freeze protection when tank < 43°F (6°C)
* The ``he*TempSetting`` fields do **not** describe when an element
runs: in Electric and High Demand the on and off settings are equal
and every ``he*DiffTempSetting`` reads 0. The measured start
differential is **mode-dependent** - at most 0.3 degC in
``ELECTRIC``, within (0.2, 0.7] degC in ``HIGH_DEMAND``, and within
(0.8, 1.0] degC in ``ENERGY_SAVER``, all measured on entry to the
mode. See :doc:`/explanation/heating-elements`.
* The ``he*TempSetting`` fields do **not** describe what happens on
**entry** to a mode: in Electric and High Demand the on and off
settings are equal and every ``he*DiffTempSetting`` reads 0. The
measured entry differential is **mode-dependent** - at most 0.3 degC
in ``ELECTRIC``, within (0.2, 0.7] degC in ``HIGH_DEMAND``, and
within (0.8, 1.0] degC in ``ENERGY_SAVER``.
* **Later in a stint it depends on the mode.** ``ENERGY_SAVER``
re-engages the upper element as the probe reaches
``heUpperOnTempSetting``, as the field describes. ``HIGH_DEMAND`` does
not: it re-engages about 2.1 degC below it. ``ELECTRIC`` is
uncharacterised. See :doc:`/explanation/heating-elements`.

**Heat Pump Specifications:**

Expand Down