Original file line number Diff line number Diff line change
Expand Up @@ -15,7 +15,7 @@ Async Python library for Thermia heat pumps on the **Genesis** platform (Atlas,
Calibra E, Calibra Cool, Calibra RXT, Diplomat Inverter), using Modbus via
[`modbus-connection`](https://home-assistant-libs.github.io/modbus-connection/).

> **Status:** early development. Only Genesis firmware 17.1 is targeted.
> **Status:** early development. Genesis firmware 17.1 is targeted; 18.0 reads the same.

This library powers the [Thermia Genesis Home Assistant integration](https://github.com/klconsultancy/ha-thermia-genesis).

Expand Down
10 changes: 6 additions & 4 deletions docs/design.md
Original file line number Diff line number Diff line change
Expand Up @@ -10,9 +10,11 @@ Domain terms are defined in [`CONTEXT.md`](../CONTEXT.md).
- Thermia heat pumps on the **Genesis** platform (Atlas, Calibra, Calibra E, Calibra Cool,
Calibra RXT, Diplomat Inverter), controlled over **Modbus**.
- Only firmware **17.1** is implemented. The register map lives in a per-version module
(`v17_1`) so other versions can be added side by side later.
- Reference hardware: Calibra 7, firmware 17.1.11, Modbus TCP, EM3 extension module with
passive cooling.
(`v17_1`) so other versions can be added side by side later. Firmware **18.0** uses the
same map: the reference pump's dump on 18.0.1 matched it address for address (errata), and
no protocol document for 18.0 is available yet.
- Reference hardware: Calibra 7, Modbus TCP, EM3 extension module with passive cooling;
firmware 17.1.11 until November 2026, then 18.0.1 (it updated itself).
- Modbus TCP first. RTU is not excluded: `modbus-connection` already supports serial and
RTU-over-TCP, so adding it is mostly config-flow work in the integration.
- Read first, then writes: the write API (#19, see Public API) covers a few settings so
Expand Down Expand Up @@ -231,7 +233,7 @@ await pump.status.write(Status.operational_mode, OperationalMode.STANDBY)
- The firmware version is read from input registers 311–313 (major, minor, micro), with
every update. `pump.firmware_version` is a `FirmwareVersion` named tuple (`str()` gives
"17.1.11", it compares as a tuple), or `None` until an update has read it.
- On a major/minor version other than 17.1 the library still uses the 17.1 map;
- On a major/minor version other than 17.1 or 18.0 the library still uses the 17.1 map;
`FirmwareVersion.supported` is then `False`, and the caller decides how to warn (the Home
Assistant integration raises a repair issue).
- Optional subsystems are detected from their "Enable ..." coils: mix valve 1 coil 11, HGW
Expand Down
1 change: 1 addition & 0 deletions docs/errata.md
Original file line number Diff line number Diff line change
Expand Up @@ -31,6 +31,7 @@ field report from another pump.
| Scale 100 (chapter 2.1) | The scale table says the transmitted value is "a tenfold larger"; the worked example in the same section transmits -5 °C as -500. | Hundredfold (the worked example; the reference pump's discharge pipe reads 2667: 26.67 °C, not 266.7 °C). |
| Footnote \*5 "Should always be set to 1 i auto mode" | Printed under the coil table of chapter 3 and with the footnotes of chapter 9, but no register refers to it. | Not applied to any register. To be verified which register it belongs to. |
| Footnotes | Printed at the end of chapter 9 instead of in their own chapter (as in 17.0). | Treated as document-wide footnotes. |
| Firmware 18.0 | No protocol document for 18.0 is available. The reference pump updated itself from 17.1.11 to 18.0.1 (noticed 2026-11-18). Its dump (`tests/fixtures/calibra7-18.0.1.json`) reads the same addresses as on 17.1.11, with no failed read and no change in any holding register; the input registers that differ follow from the compressor running during the 18.0.1 dump and idle during the 17.1.11 one. | 18.0 uses the 17.1 map and counts as supported. A register 18.0 adds, or a changed meaning behind an equal value, would not show in a dump. |

## Undocumented behaviour

Expand Down
9 changes: 5 additions & 4 deletions src/thermia_genesis/firmware.py
Original file line number Diff line number Diff line change
Expand Up @@ -2,8 +2,9 @@

from typing import NamedTuple

# The firmware the register map is written for; docs/design.md (Scope).
SUPPORTED = (17, 1)
# The firmware versions the register map is written for or checked against;
# docs/design.md (Scope).
SUPPORTED = frozenset({(17, 1), (18, 0)})


class FirmwareVersion(NamedTuple):
Expand All @@ -19,5 +20,5 @@ def __str__(self) -> str:

@property
def supported(self) -> bool:
"""Whether the register map is written for this major.minor version (17.1)."""
return (self.major, self.minor) == SUPPORTED
"""Whether the register map applies to this major.minor version (17.1 or 18.0)."""
return (self.major, self.minor) in SUPPORTED